{"id":69732,"date":"2025-03-16T17:48:43","date_gmt":"2025-03-16T16:48:43","guid":{"rendered":"https:\/\/panelsandwich.org\/industrial-roofing-insulation-keys-to-choosing-the-best-material\/"},"modified":"2026-10-18T01:19:02","modified_gmt":"2026-10-17T23:19:02","slug":"industrial-roofing-insulation-keys-to-choosing-the-best-material","status":"publish","type":"post","link":"https:\/\/panelsandwich.org\/en\/industrial-roofing-insulation-keys-to-choosing-the-best-material\/","title":{"rendered":"Industrial roofing insulation: how to choose material"},"content":{"rendered":"<p>The most direct way to insulate the roof of an industrial building is to cover it with <strong>sandwich panel<\/strong>: two galvanised and prelacquered steel sheets with an insulating core of polyurethane (PUR), polyisocyanurate (PIR) or rock wool. In a single piece you have thermal and acoustic insulation, watertight closure and finish, and it installs much faster than a traditional construction system. <\/p>\n<p>To choose the right material you need to look at five things: the type of core, the thickness, the building environment (humidity, corrosion), the activity carried out inside (warehouse, food industry, cold storage) and the regulations it must comply with, especially regarding energy efficiency and fire.<\/p>\n<h2>Why insulate the roof of an industrial building<\/h2>\n<p>The roof is the most exposed part of the building. It receives full sun in summer, cold in winter and humidity all year round. If it is poorly insulated:  <\/p>\n<ul>\n<li>A lot of energy is lost and heating and cooling costs soar.<\/li>\n<li>The interior temperature varies greatly and working conditions worsen.<\/li>\n<li>Dampness appears that affects the structure and what is stored.<\/li>\n<li>In buildings with machinery, noise is transmitted more easily.<\/li>\n<\/ul>\n<p>Good insulation maintains a stable temperature, reduces consumption and improves the comfort of those working inside.<\/p>\n<h2>Options for the roof of an industrial building<\/h2>\n<table>\n<thead>\n<tr>\n<th>Solution<\/th>\n<th>What it provides<\/th>\n<th>When it fits<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Simple corrugated sheet<\/td>\n<td>Lightweight closure, no insulation<\/td>\n<td>When you don&#8217;t need to insulate<\/td>\n<\/tr>\n<tr>\n<td>Polyurethane (PUR) sandwich panel<\/td>\n<td>Good general thermal insulation<\/td>\n<td>Factories, warehouses and workshops<\/td>\n<\/tr>\n<tr>\n<td>PIR sandwich panel<\/td>\n<td>Better fire performance and greater thermal stability<\/td>\n<td>Buildings with higher safety requirements<\/td>\n<\/tr>\n<tr>\n<td>Rock wool sandwich panel<\/td>\n<td>Fire resistance and acoustic insulation<\/td>\n<td>Fire risk or noisy activity<\/td>\n<\/tr>\n<tr>\n<td>Refrigerator panel<\/td>\n<td>High-thickness insulation and watertight joints<\/td>\n<td>Cold rooms and perishable storage<\/td>\n<\/tr>\n<tr>\n<td>Panel with hygienic interior<\/td>\n<td>Easy-to-clean surface<\/td>\n<td>Food and pharmaceutical industry<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Simple sheet is cheaper, but does not insulate. If you&#8217;re unsure between the two, read the <a href=\"https:\/\/panelsandwich.org\/en\/advantages-of-sandwich-panels-over-other-traditional-enclosures\/\">differences between insulated panel and simple sheet<\/a>. For most buildings with people working inside, the <a href=\"https:\/\/panelsandwich.org\/en\/sandwich-panel-for-roofing\/\">roofing sandwich panel<\/a> is the balanced option.  <\/p>\n<h2>What to look at when choosing insulation<\/h2>\n<h3>Core type<\/h3>\n<p>Polyurethane (PUR) is the most widely used for general thermal insulation. Polyisocyanurate (PIR) offers greater fire resistance and thermal stability. Rock wool insulates slightly less per centimetre than polyurethane, but is fireproof and absorbs noise better. If your building has fire requirements, look at the <a href=\"https:\/\/panelsandwich.org\/en\/rock-wool-sandwich-panel\/\">rock wool sandwich panel<\/a>.   <\/p>\n<h3>Thickness<\/h3>\n<p>The thicker the core, the more the panel insulates. In areas with extreme temperatures it is advisable to go for greater thicknesses. As a rough guide:  <\/p>\n<ul>\n<li>Standard logistics warehouse: 40 to 50 mm.<\/li>\n<li>Food industry: 60 to 80 mm.<\/li>\n<li>Freezer rooms: 100 to 200 mm.<\/li>\n<\/ul>\n<p>The final thickness is set by the technical project according to the climate zone and the Technical Building Code.<\/p>\n<h3>Interior environment<\/h3>\n<p>If the building is humid or has a corrosive environment, choose panels with anti-corrosion treatments and protection against humidity.<\/p>\n<h3>Activity and regulations<\/h3>\n<p>In the food and pharmaceutical sectors the building envelope must meet hygiene and fire resistance requirements. For industrial cold storage, the <a href=\"https:\/\/panelsandwich.org\/en\/cold-room-sandwich-panel\/\">refrigerator sandwich panel<\/a> is designed to maintain low temperatures stably. <\/p>\n<h2>Installation: fast, dry and expandable<\/h2>\n<p>Sandwich panel is installed by fitting pieces together and fixing them to the purlins. There is no wet work or so many coordinated trades. This translates into:  <\/p>\n<ul>\n<li>Shorter construction time and earlier start-up of activity.<\/li>\n<li>Lower labour cost and lower indirect costs.<\/li>\n<li>Less weight on the structure than other systems, such as concrete.<\/li>\n<li>Buildings that can be expanded, modified or adapted to other uses in the future.<\/li>\n<\/ul>\n<p>If you also need the structure, at <a href=\"https:\/\/starmodul.com\/\" target=\"_blank\" rel=\"noopener\">starmodul.com<\/a> we design custom bolted metal structures, designed to be assembled on site and expanded when needed.<\/p>\n<h2>Refurbishing the roof of an existing building<\/h2>\n<p>Many old buildings have roofs that no longer insulate or have leaks. Replacing them with sandwich panel improves insulation and watertightness in one go. If your roof is asbestos cement, find out beforehand about <a href=\"https:\/\/panelsandwich.org\/en\/what-is-the-problem-with-fiber-cement\/\">asbestos cement problems<\/a> to plan the work properly. Take advantage of the refurbishment to add skylights and gain natural light.   <\/p>\n<h2>What you gain in the long term<\/h2>\n<ul>\n<li><strong>Energy savings.<\/strong> Menos gasto en calefacci\u00f3n y aire acondicionado, a\u00f1o tras a\u00f1o.<\/li>\n<li><strong>Less maintenance.<\/strong> Un panel de calidad bien instalado pide pocas reparaciones.<\/li>\n<li><strong>More protection.<\/strong> Resiste impactos y condiciones clim\u00e1ticas duras, y protege lo que hay dentro.<\/li>\n<li><strong>Easier to comply with regulations.<\/strong> Ayuda a adaptarse a las exigencias de eficiencia energ\u00e9tica y seguridad industrial.<\/li>\n<\/ul>\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"Aislamiento De Techos Industriales Con PanelSandwich\" width=\"800\" height=\"450\" src=\"https:\/\/www.youtube.com\/embed\/SA0qEP06N2s?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n<h2>Frequently asked questions<\/h2>\n<h3>What is the best insulation for the roof of an industrial building?<\/h3>\n<p>It depends on the use. Polyurethane is the general option. PIR improves fire performance. Rock wool is the choice when fire protection or noise is a priority.   <\/p>\n<h3>What panel thickness does an industrial building need?<\/h3>\n<p>For a standard warehouse you work with 40 to 50 mm, and more in areas with extreme climate or with air conditioning. The technical project sets the final value. <\/p>\n<h3>Sandwich panel or simple sheet?<\/h3>\n<p>If you need insulation, sandwich panel. Simple sheet only closes; it does not protect from heat or cold. <\/p>\n<h3>Does sandwich panel reduce noise inside the building?<\/h3>\n<p>Yes, it provides acoustic insulation. If noise is a significant problem, the rock wool core offers better acoustic performance than polyurethane. <\/p>\n<h3>What panel is used in the food industry?<\/h3>\n<p>Panels with hygienic interior finish and, in cold areas, refrigerator panel with PUR or PIR core.<\/p>\n<p>Are you going to build or renovate the roof of your building? <a href=\"https:\/\/panelsandwich.org\/en\/contact\/\">Request a no-obligation quote<\/a> or call us on 699 147 762. We advise you on the right panel, supply it to measure with trims and fixings, and can install it with our <a href=\"https:\/\/panelsandwich.org\/en\/assembly-service-starmodul\/\">installation service<\/a>. <\/p>\n","protected":false},"excerpt":{"rendered":"<p>The most direct way to insulate the roof of an industrial building is to cover it with sandwich panel: two galvanised and prelacquered steel sheets with an insulating core of polyurethane (PUR), polyisocyanurate (PIR) or rock wool. In a single piece you have thermal and acoustic insulation, watertight closure and finish, and it installs much [&hellip;]<\/p>\n","protected":false},"author":5963,"featured_media":69741,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[2977],"tags":[],"class_list":["post-69732","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-sandwich-panels-en"],"_links":{"self":[{"href":"https:\/\/panelsandwich.org\/en\/wp-json\/wp\/v2\/posts\/69732","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/panelsandwich.org\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/panelsandwich.org\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/panelsandwich.org\/en\/wp-json\/wp\/v2\/users\/5963"}],"replies":[{"embeddable":true,"href":"https:\/\/panelsandwich.org\/en\/wp-json\/wp\/v2\/comments?post=69732"}],"version-history":[{"count":0,"href":"https:\/\/panelsandwich.org\/en\/wp-json\/wp\/v2\/posts\/69732\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/panelsandwich.org\/en\/wp-json\/wp\/v2\/media\/69741"}],"wp:attachment":[{"href":"https:\/\/panelsandwich.org\/en\/wp-json\/wp\/v2\/media?parent=69732"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/panelsandwich.org\/en\/wp-json\/wp\/v2\/categories?post=69732"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/panelsandwich.org\/en\/wp-json\/wp\/v2\/tags?post=69732"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}