{"id":72369,"date":"2026-01-07T16:39:39","date_gmt":"2026-01-07T15:39:39","guid":{"rendered":"https:\/\/panelsandwich.org\/common-mistakes-when-installing-sandwich-panels\/"},"modified":"2026-11-09T10:46:17","modified_gmt":"2026-11-09T09:46:17","slug":"common-mistakes-when-installing-sandwich-panels","status":"publish","type":"post","link":"https:\/\/panelsandwich.org\/en\/common-mistakes-when-installing-sandwich-panels\/","title":{"rendered":"Common mistakes when installing sandwich panels and how to avoid them"},"content":{"rendered":"<div style=\"background-color: #f4f5f7; font-family: 'Segoe UI', Roboto, Helvetica, Arial, sans-serif; line-height: 1.6; color: #333333; padding: 20px;\">\n<div style=\"max-width: 800px; margin: 0 auto; background-color: #ffffff; border-radius: 8px; padding: 40px; box-shadow: 0 10px 40px -10px rgba(16, 24, 40, 0.15); border-top: 5px solid #fba905;\">\n<p style=\"margin-bottom: 18px; color: #444;\">Almost all problems with a sandwich panel roof or facade come from installation, not the material: <strong style=\"color: #101828;\">insufficient slope, an uneven structure, wrongly chosen or overtightened screws, overlaps the wrong way round, cuts made with an angle grinder, and unsealed Flashing<\/strong>. These 9 mistakes explain most leaks, condensation, and rust stains. For each one, here\u2019s how to avoid it.  <\/p>\n<h2 style=\"color: #101828; font-size: 1.6rem; margin-top: 40px; margin-bottom: 20px; border-bottom: 2px solid #eee; padding-bottom: 10px; font-weight: 700;\">1. Installing with less than the minimum slope<\/h2>\n<p style=\"margin-bottom: 18px; color: #444;\">Each model has its minimum slope: 5% for panels with flashing and corrugated panels, and 10% for tile-effect panels. With less pitch, water pools in the ribs and ends up getting in through overlaps and screws. It\u2019s explained in <a href=\"https:\/\/panelsandwich.org\/en\/key-considerations-for-installing-sandwich-panel-roofing\/\" style=\"color: #101828; text-decoration: none; border-bottom: 2px solid #fba905; font-weight: 600;\">minimum slope and key tips for installing sandwich panels on roofs<\/a>.  <\/p>\n<h2 style=\"color: #101828; font-size: 1.6rem; margin-top: 40px; margin-bottom: 20px; border-bottom: 2px solid #eee; padding-bottom: 10px; font-weight: 700;\">2. Uneven structure or purlins spaced too far apart<\/h2>\n<p style=\"margin-bottom: 18px; color: #444;\">If the purlins aren\u2019t in the same plane, the panel sits twisted and the overlaps open up. If they\u2019re too far apart, the panel deflects under snow or wind. Check for level before installing and keep to the spacing shown in the load tables on each datasheet. More details in the <a href=\"https:\/\/panelsandwich.org\/en\/what-structure-you-need-before-installing-sandwich-panels\/\" style=\"color: #101828; text-decoration: none; border-bottom: 2px solid #fba905; font-weight: 600;\">structure guide for sandwich panels<\/a>.   <\/p>\n<h2 style=\"color: #101828; font-size: 1.6rem; margin-top: 40px; margin-bottom: 20px; border-bottom: 2px solid #eee; padding-bottom: 10px; font-weight: 700;\">3. Wrong screw or overtightened\/undertightened<\/h2>\n<ul style=\"margin: 0 0 20px 0; padding-left: 22px;\">\n<li style=\"margin-bottom: 10px; color: #444;\">Each substrate needs its own screw: <a href=\"https:\/\/panelsandwich.org\/en\/sandwich-panel-screws\/\" style=\"color: #101828; text-decoration: none; border-bottom: 2px solid #fba905; font-weight: 600;\">metal purlin, timber, or concrete<\/a>.<\/li>\n<li style=\"margin-bottom: 10px; color: #444;\">On roofs, screw into the crest of the rib, never in the valley.<\/li>\n<li style=\"margin-bottom: 10px; color: #444;\">The EPDM washer should be compressed, not crushed. If you overtighten it, it cracks; if you undertighten it, it won\u2019t seal. <\/li>\n<li style=\"margin-bottom: 10px; color: #444;\">Use a torque-controlled screwdriver and don\u2019t reuse screws.<\/li>\n<\/ul>\n<h2 style=\"color: #101828; font-size: 1.6rem; margin-top: 40px; margin-bottom: 20px; border-bottom: 2px solid #eee; padding-bottom: 10px; font-weight: 700;\">4. Overlaps the wrong way round<\/h2>\n<p style=\"margin-bottom: 18px; color: #444;\">Install from bottom to top and against the prevailing wind. If you do it the other way round, driving rain gets in through the overlap. When a roof slope needs two panels in length, the upper panel overlaps the lower one. With low slopes, that overlap is sealed with <a href=\"https:\/\/panelsandwich.org\/en\/mounting-accessory-butyl-tape\/\" style=\"color: #101828; text-decoration: none; border-bottom: 2px solid #fba905; font-weight: 600;\">butyl tape<\/a>.   <\/p>\n<h2 style=\"color: #101828; font-size: 1.6rem; margin-top: 40px; margin-bottom: 20px; border-bottom: 2px solid #eee; padding-bottom: 10px; font-weight: 700;\">5. Cutting with an angle grinder<\/h2>\n<p style=\"margin-bottom: 18px; color: #444;\">The grinder\u2019s heat burns the sheet coating and the insulation. The cut edge rusts within a few months, and the sparks leave rust spots around it. Cut with a jigsaw or a fine-tooth circular saw and, if you can, order the panels <a href=\"https:\/\/panelsandwich.org\/en\/how-to-measure-sandwich-panel-correctly\/\" style=\"color: #101828; text-decoration: none; border-bottom: 2px solid #fba905; font-weight: 600;\">to the exact size<\/a>.  <\/p>\n<h2 style=\"color: #101828; font-size: 1.6rem; margin-top: 40px; margin-bottom: 20px; border-bottom: 2px solid #eee; padding-bottom: 10px; font-weight: 700;\">6. Leaving swarf on top<\/h2>\n<p style=\"margin-bottom: 18px; color: #444;\">Swarf from screws and cuts rusts with the first rain and stains the sheet. Sweep with a soft brush after finishing each section. <\/p>\n<h2 style=\"color: #101828; font-size: 1.6rem; margin-top: 40px; margin-bottom: 20px; border-bottom: 2px solid #eee; padding-bottom: 10px; font-weight: 700;\">7. Forgetting the protective film<\/h2>\n<p style=\"margin-bottom: 18px; color: #444;\">Remove the film once you\u2019ve finished installing each panel. If it sits in the sun for weeks, the adhesive bonds to the sheet and is very hard to remove. <\/p>\n<h2 style=\"color: #101828; font-size: 1.6rem; margin-top: 40px; margin-bottom: 20px; border-bottom: 2px solid #eee; padding-bottom: 10px; font-weight: 700;\">8. Unsealed Flashing or a different colour<\/h2>\n<p style=\"margin-bottom: 18px; color: #444;\">Junctions with walls, chimneys, skylights, and the ridge are where water gets in most often. Use <a href=\"https:\/\/panelsandwich.org\/en\/sandwich-panel-trim\/\" style=\"color: #101828; text-decoration: none; border-bottom: 2px solid #fba905; font-weight: 600;\">sheet-metal Flashing<\/a> in the same colour as the panel, seal the junctions, and fit a <a href=\"https:\/\/panelsandwich.org\/en\/mounting-accessory-chimney-cap\/\" style=\"color: #101828; text-decoration: none; border-bottom: 2px solid #fba905; font-weight: 600;\">chimney cap<\/a> on chimneys. <\/p>\n<h2 style=\"color: #101828; font-size: 1.6rem; margin-top: 40px; margin-bottom: 20px; border-bottom: 2px solid #eee; padding-bottom: 10px; font-weight: 700;\">9. Using single sheet where a panel is needed<\/h2>\n<p style=\"margin-bottom: 18px; color: #444;\">A single sheet without insulation will drip from condensation in livestock buildings, kitchens, or damp warehouses. In those cases you need <a href=\"https:\/\/panelsandwich.org\/en\/sandwich-panel-for-roofing\/\" style=\"color: #101828; text-decoration: none; border-bottom: 2px solid #fba905; font-weight: 600;\">roof sandwich panels<\/a> or <a href=\"https:\/\/panelsandwich.org\/en\/sandwich-panel-for-farms-agropanel\/\" style=\"color: #101828; text-decoration: none; border-bottom: 2px solid #fba905; font-weight: 600;\">agropanel<\/a>. <\/p>\n<h2 style=\"color: #101828; font-size: 1.6rem; margin-top: 40px; margin-bottom: 20px; border-bottom: 2px solid #eee; padding-bottom: 10px; font-weight: 700;\">Checklist before installing<\/h2>\n<div style=\"overflow-x: auto;\">\n<table style=\"width: 100%; border-collapse: collapse; margin: 30px 0; border-radius: 6px; overflow: hidden; box-shadow: 0 2px 10px rgba(0,0,0,0.05); background-color: #fff;\">\n<thead>\n<tr style=\"background-color: #101828; color: #ffffff;\">\n<th style=\"padding: 15px; text-align: left; text-transform: uppercase; font-size: 0.85rem; letter-spacing: 0.5px;\">Item<\/th>\n<th style=\"padding: 15px; text-align: left; text-transform: uppercase; font-size: 0.85rem; letter-spacing: 0.5px;\">What to check<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr style=\"border-bottom: 1px solid #eee;\">\n<td style=\"padding: 15px; color: #101828; font-weight: bold;\">Slope<\/td>\n<td style=\"padding: 15px; color: #333;\">Equal to or greater than the model\u2019s minimum.<\/td>\n<\/tr>\n<tr style=\"border-bottom: 1px solid #eee;\">\n<td style=\"padding: 15px; color: #101828; font-weight: bold;\">Structure<\/td>\n<td style=\"padding: 15px; color: #333;\">Purlins in the same plane and spacing as per the datasheet.<\/td>\n<\/tr>\n<tr style=\"border-bottom: 1px solid #eee;\">\n<td style=\"padding: 15px; color: #101828; font-weight: bold;\">Screws<\/td>\n<td style=\"padding: 15px; color: #333;\">Correct type for the substrate, with EPDM washer and enough of them.<\/td>\n<\/tr>\n<tr style=\"border-bottom: 1px solid #eee;\">\n<td style=\"padding: 15px; color: #101828; font-weight: bold;\">Installation direction<\/td>\n<td style=\"padding: 15px; color: #333;\">Bottom to top and against the wind.<\/td>\n<\/tr>\n<tr style=\"border-bottom: 1px solid #eee;\">\n<td style=\"padding: 15px; color: #101828; font-weight: bold;\">Tools<\/td>\n<td style=\"padding: 15px; color: #333;\">Cold-cut saw and torque-controlled screwdriver.<\/td>\n<\/tr>\n<tr style=\"border-bottom: 1px solid #eee;\">\n<td style=\"padding: 15px; color: #101828; font-weight: bold;\">Flashing<\/td>\n<td style=\"padding: 15px; color: #333;\">Ordered at the same time as the panels, in the same colour.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2 style=\"color: #101828; font-size: 1.6rem; margin-top: 40px; margin-bottom: 20px; border-bottom: 2px solid #eee; padding-bottom: 10px; font-weight: 700;\">Frequently asked questions<\/h2>\n<div style=\"background-color: #f8f9fa; border-left: 4px solid #fba905; padding: 20px; margin-bottom: 15px; border-radius: 0 6px 6px 0;\">\n<h3 style=\"display: block; font-weight: bold; color: #101828; margin: 0 0 8px 0; font-size: 1rem; line-height: 1.6;\">What are the drawbacks of sandwich panels?<\/h3>\n<p style=\"margin: 0; color: #555;\">When installed properly, there are few: they insulate less against rain noise than a heavy roof (except rock wool), and aesthetically they\u2019re not everyone\u2019s taste. Most issues blamed on them\u2014like leaks, rust, or condensation\u2014are installation mistakes. We explain it in <a href=\"https:\/\/panelsandwich.org\/en\/advantages-of-sandwich-panels-over-other-traditional-enclosures\/\" style=\"color: #101828; text-decoration: none; border-bottom: 2px solid #fba905; font-weight: 600;\">advantages and disadvantages of sandwich panels<\/a>.  <\/p>\n<\/div>\n<div style=\"background-color: #f8f9fa; border-left: 4px solid #fba905; padding: 20px; margin-bottom: 15px; border-radius: 0 6px 6px 0;\">\n<h3 style=\"display: block; font-weight: bold; color: #101828; margin: 0 0 8px 0; font-size: 1rem; line-height: 1.6;\">Why does a sandwich panel roof drip?<\/h3>\n<p style=\"margin: 0; color: #555;\">Almost always for one of these reasons: insufficient slope, screws in the valley or not tightened correctly, overlaps the wrong way round, or unsealed Flashing.<\/p>\n<\/div>\n<div style=\"background-color: #f8f9fa; border-left: 4px solid #fba905; padding: 20px; margin-bottom: 15px; border-radius: 0 6px 6px 0;\">\n<h3 style=\"display: block; font-weight: bold; color: #101828; margin: 0 0 8px 0; font-size: 1rem; line-height: 1.6;\">Can a poorly installed roof be fixed?<\/h3>\n<p style=\"margin: 0; color: #555;\">Yes, in many cases: screws are replaced, overlaps are sealed, and the missing Flashing is installed. If the slope is insufficient, the solution is more expensive. <\/p>\n<\/div>\n<div style=\"background-color: #f8f9fa; border-left: 4px solid #101828; padding: 20px; margin: 30px 0; border-radius: 0 6px 6px 0;\"><span style=\"display: block; font-weight: bold; color: #101828; margin-bottom: 5px; text-transform: uppercase; font-size: 0.85rem; letter-spacing: 0.5px;\">Need a quote?<\/span><\/p>\n<p style=\"margin: 0; color: #555;\">If you\u2019re installing it yourself, send us the measurements and we\u2019ll prepare made-to-measure panels, Flashing, and fixings. If you\u2019d rather not take the risk, we offer an <a href=\"https:\/\/panelsandwich.org\/en\/assembly-service-starmodul\/\" style=\"color: #101828; text-decoration: none; border-bottom: 2px solid #fba905; font-weight: 600;\">installation service<\/a>. <a href=\"https:\/\/panelsandwich.org\/en\/contact\/\" style=\"color: #101828; text-decoration: none; border-bottom: 2px solid #fba905; font-weight: 600;\">Request a quote<\/a> or call us on 699 147 762. <\/p>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Almost all problems with a sandwich panel roof or facade come from installation, not the material: insufficient slope, an uneven structure, wrongly chosen or overtightened screws, overlaps the wrong way round, cuts made with an angle grinder, and unsealed Flashing. These 9 mistakes explain most leaks, condensation, and rust stains. For each one, here\u2019s how [&hellip;]<\/p>\n","protected":false},"author":5963,"featured_media":72370,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[2977],"tags":[],"class_list":["post-72369","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-sandwich-panels-en"],"_links":{"self":[{"href":"https:\/\/panelsandwich.org\/en\/wp-json\/wp\/v2\/posts\/72369","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/panelsandwich.org\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/panelsandwich.org\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/panelsandwich.org\/en\/wp-json\/wp\/v2\/users\/5963"}],"replies":[{"embeddable":true,"href":"https:\/\/panelsandwich.org\/en\/wp-json\/wp\/v2\/comments?post=72369"}],"version-history":[{"count":0,"href":"https:\/\/panelsandwich.org\/en\/wp-json\/wp\/v2\/posts\/72369\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/panelsandwich.org\/en\/wp-json\/wp\/v2\/media\/72370"}],"wp:attachment":[{"href":"https:\/\/panelsandwich.org\/en\/wp-json\/wp\/v2\/media?parent=72369"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/panelsandwich.org\/en\/wp-json\/wp\/v2\/categories?post=72369"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/panelsandwich.org\/en\/wp-json\/wp\/v2\/tags?post=72369"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}