PRODUCT DESCRIPTION
The natural wood facade sandwich panel with fir frieze combines thermal insulation with an exposed authentic natural wood face. The technical configuration used in this datasheet incorporates a 10 mm fir frieze, an insulating core, and a water-repellent top substrate.
This is a particularly interesting solution when seeking an enclosure or cladding with the aesthetic of real wood and the performance characteristics of a prefabricated insulating panel. The manufacturer’s documentation considers the use of this panel family for walls, ceilings, floors, and roofs; for specific facade applications, the structural arrangement, fixings, orientation, and exterior exposure of the project must be verified.
The available composition includes a 16 or 19 mm water-repellent chipboard top substrate, an extruded polystyrene, expanded polystyrene, or rock wool core, and a 10 mm natural fir frieze exposed face.
| Element | Configuration |
|---|---|
| Top Face | 16 or 19 mm Water-Repellent Chipboard |
| Insulating Core | Extruded Polystyrene, Expanded Polystyrene, or Rock Wool |
| Exposed Face | 10 mm Natural Fir Frieze |
| Nominal Width | 600 mm |
| Top Face Width | 598 mm |
The main difference compared to a wood-imitation metal panel is that this solution uses natural fir wood on its exposed face. The grain, knots, and tonal variations are part of the authentic wood appearance.
The finish can be supplied in natural colorless or treated with different water-based varnishes, color tones, and pickled finishes. When the final appearance is critical for a facade or visible cladding, we recommend checking a real sample beforehand.
For use as a natural wood facade sandwich panel, the orientation, weather protection, fixings, trims, and joints must be specifically resolved for the project. The base technical datasheet is particularly documented for wood panels used in interior ceilings and roofs.
The natural wood facade sandwich panel must be installed on a correctly sized structure or substructure. Before using it as a vertical enclosure, the panel’s fixing, wind loads, perimeter joints, and wood protection against exterior exposure must be verified.
The technical datasheet publishes support separations for different panel lengths. These values are a mechanical reference for the product and do not replace the specific calculation for a facade.
| Panel Size | Indicated Support Separation |
|---|---|
| 2490 × 600 mm | 620 – 830 – 1245 mm |
| 2990 × 600 mm | 745 – 990 – 1495 mm |
| 3290 × 600 mm | 822 – 1010 – 1645 mm |
| 3590 × 600 mm | 718 – 898 – 1197 – 1795 mm |
DECLARED PERFORMANCE
| Core Thickness (mm) | U H-16 (W/m²K) | U H-19 (W/m²K) | Weight (kg/m²) |
|---|---|---|---|
| 30 | 0.797 | 0.784 | 16.18 |
| 40 | 0.642 | 0.633 | 16.48 |
| 50 | 0.564 | 0.557 | 16.78 |
| 60 | 0.486 | 0.481 | 17.08 |
| 80 | 0.381 | 0.377 | 17.68 |
| 100 | 0.328 | 0.326 | 18.28 |
| 120 | 0.279 | 0.277 | 18.88 |
| 140 | 0.230 | 0.229 | 19.48 |
| 160 | 0.203 | 0.203 | 20.08 |
| 180 | 0.187 | 0.186 | 20.68 |
| 200 | 0.174 | 0.173 | 21.28 |
Values published for the technical datasheet configuration. Transmittance is identified as XPS in the manufacturer’s table.
The technical datasheet provides design loads for a 3-support configuration with a maximum deflection of L/300. The following values are expressed in kg/m².
| Core Thickness (mm) | 2490 mm Panel / 1245 Span | 2990 mm Panel / 1495 Span | 3290 mm Panel / 1645 Span | 3590 mm Panel / 1795 Span |
|---|---|---|---|---|
| 30 | 206 | 172 | 158 | — |
| 40 | 277 | 230 | 210 | — |
| 50 | 348 | 290 | 264 | 235 |
| 60 | 416 | 345 | 315 | 290 |
| 80 | 558 | 464 | 420 | 385 |
| 100 | 692 | 575 | 528 | 478 |
| 120 | 830 | 690 | 630 | 580 |
| 140 | 970 | 808 | 735 | 673 |
| 160 | 1110 | 925 | 840 | 768 |
| 180 | 1250 | 1040 | 950 | 870 |
| 200 | 1380 | 1130 | 1050 | 960 |
Important: loads are understood as design loads. The solution must be verified for each project, especially when spans, number of supports, core, or composition change.
TECHNICAL DATA SHEET
Consult the technical datasheet for the natural fir frieze panel used as the basis for this reference. It includes composition, dimensions, acoustic insulation, reaction to fire, finishes, support separation, design loads, thermal transmittance, and weights.
For its specific use as a facade, the complete constructive solution of the project must be checked.
QUESTIONS
It is a prefabricated insulating panel with an exposed natural wood face. This reference uses a 10 mm fir frieze, an insulating core, and a water-repellent top substrate.
It is authentic natural fir wood. It is not a metal sheet painted or printed with a wood effect.
The family of wood panels can be integrated into walls and enclosures, but for a specific facade application, fixings, support structure, wind loads, trims, and wood protection against exterior exposure must be verified.
The datasheet includes extruded polystyrene, expanded polystyrene, or rock wool cores. Thermal performance depends on the selected core and thickness.
The documentation declares 32.7 dBA of airborne sound insulation and Rw (C, Ctr)=33 (-1,-3).
It can be supplied in a natural colorless finish or with different water-based varnishes, color tones, and pickled finishes. As it is authentic wood, natural variations in grain and tone exist.
FACADE AND WOOD PANELS
LATEST ARTICLES
Explore content on panel selection, insulation, installation, maintenance, refurbishment and real-world applications.
TAMBIÉN TE PUEDE INTERESAR

SERVICIO DE OBRA
Valoramos obra nueva, rehabilitación, sustitución de cubiertas y fachadas, colocación de rematería y trabajos con chapa o lucernarios.
El presupuesto depende de la geometría, altura, accesos, medios auxiliares, ubicación, fijaciones y encuentros que deba resolver la obra.
PRESUPUESTO PERSONALIZADO
Indica tipo de panel, superficie, espesor, localidad y si necesitas suministro o montaje. Revisaremos los datos para preparar una propuesta ajustada.
SOLICITUD RÁPIDA
Completa los datos principales y prepararemos una propuesta ajustada a tu proyecto.