PRODUCT DESCRIPTION
The RAL 8004 Tile Red Tile Sandwich Panel is an insulating roof panel with a geometry inspired by traditional tiles. It consists of two profiled metal sheets and a rigid core of polyurethane (PUR) or polyisocyanurate (PIR).
The outer sheet incorporates a textured finish that enhances visual similarity to a conventional tiled roof. The color RAL 8004 Tile Red is the primary reference for this product.
It is suitable for roofs with a minimum slope of 10%. The effective width is 1,000 mm and it is manufactured in thicknesses of 30, 40, and 50 mm.
Manufacturing lengths range from 2.10 to 14.00 m in multiples of 0.35 m, with a maximum recommended length of 8.05 m.
The PUR or PIR core has a declared thermal conductivity of 0.0207 W/m·K and a density of 40 kg/m³.
Insulating panel for roofs with a minimum slope of 10%. Its geometry replicates the shape of a tiled roof and combines exterior finish, enclosure, and insulation in a single prefabricated element.
| Thicknesses | 30, 40, and 50 mm ±2 mm |
|---|---|
| Effective width | 1,000 mm ±2 mm |
| Longitudinal Module | 350 mm |
| Approximate Profile Separation | 200 mm |
| Approximate Wave Height | 50 mm |
| Manufacturing Length | 2.10 – 14.00 m, in multiples of 0.35 m |
| Maximum Recommended Length | 8.05 m |
The standard exterior finish is 25 µm textured polyester paint. The main color for this product is RAL 8004 Tile Red.
The technical documentation also includes other exterior finishes such as RAL 8023 Light Tile Red, RAL 9005 Jet Black, and aged finishes with a traditional appearance.
For the interior face, RAL 9010 Pure White, textured wood finish, and other decorative finishes are considered. The possibility of a lacquered aluminum metallic coating is also indicated.
Colors displayed on screen are indicative. When the tone is critical, a real sample should be checked before confirming the order.
The installation of the RAL 8004 Tile-Effect Sandwich Panel must be carried out on a correctly sized structure and with a minimum slope of 10%.
In more severe environments, the technical documentation recommends applying silicone to the panel joint to help prevent condensation.
Important: admissible spans must be checked using the load tables and the actual conditions of each roof.
DECLARED PERFORMANCE
| Configuration | Tile-effect insulated roof panel |
|---|---|
| Manufacturing standard | EN 14509 · CE marking |
| Minimum slope | 10% |
| Thicknesses | 30, 40 and 50 mm (±2 mm) |
| Useful width | 1,000 mm (±2 mm) |
| Length | 2.10 to 14.00 m, made to measure in multiples of 0.35 m · recommended up to 8.05 m |
| Wave | 50 mm high · 200 mm pitch · 350 mm longitudinal module |
| Steel sheet | S250GD, galvanised |
| Sheet thicknesses | 0.4 / 0.5 / 0.6 mm |
| Core | PUR or PIR · 40 kg/m³ |
| Thermal conductivity | λ = 0.0207 W/m·K |
| Reaction to fire | High-performance PIR: B-s1,d0 · PUR: not certified |
| Coating | 25 µm textured polyester · 55 µm special coating |
| Inner face | Ribbed or planked profile · optional 180 µm wood-effect PVC or pre-painted aluminium |
| Colours | RAL 8004 tile red, textured · inner face RAL 9010 or planked wood finish · other RAL colours on request |
| Thickness | U-value Transmittance | Weight 0.5/0.4 | Weight 0.5/0.5 |
|---|---|---|---|
| 30 mm | 0.45 W/m²·K | 10.8 kg/m² | 11.7 kg/m² |
| 40 mm | 0.37 | 11.2 | 12.1 |
| 50 mm | 0.31 | 11.6 | 12.5 |
| Thickness | U-value (W/m²·K) | Weight 0.5/0.4 (kg/m²) | Weight 0.5/0.5 (kg/m²) |
|---|---|---|---|
| 30 mm | 0.45 | 10.8 | 11.7 |
| 40 mm | 0.37 | 11.2 | 12.1 |
| 50 mm | 0.31 | 11.6 | 12.5 |
The technical data sheet includes tables of uniformly distributed loads for spans from 1.05 to 3.50 m, differentiating upward and downward loads, single or multiple support, and sheet configurations of 0.5/0.4 and 0.5/0.5 mm.
These tables are a technical reference and do not replace project calculations. Deben verificarse las cargas reales de viento, nieve, mantenimiento, número de apoyos y condiciones específicas de la cubierta.
Swipe the table
| Thickness | Load | Permissible load (kN/m²) by distance between supports L (m) | |||||||
|---|---|---|---|---|---|---|---|---|---|
| 1.05 m | 1.40 m | 1.75 m | 2.10 m | 2.45 m | 2.80 m | 3.15 m | 3.50 m | ||
| 30 mm | ▲ | 2.52 | 1.55 | 1.08 | 0.81 | 0.64 | 0.52 | 0.44 | 0.37 |
| ▼ | 1.86 | 1.10 | 0.73 | 0.51 | 0.37 | — | — | — | |
| 40 mm | ▲ | 2.69 | 1.70 | 1.21 | 0.92 | 0.73 | 0.60 | 0.51 | 0.43 |
| ▼ | 1.98 | 1.20 | 0.81 | 0.59 | 0.44 | 0.33 | — | — | |
| 50 mm | ▲ | 2.86 | 1.85 | 1.35 | 1.04 | 0.84 | 0.69 | 0.58 | 0.50 |
| ▼ | 2.11 | 1.32 | 0.91 | 0.67 | 0.50 | 0.39 | 0.30 | — | |
Swipe the table
| Thickness | Load | Permissible load (kN/m²) by distance between supports L (m) | |||||||
|---|---|---|---|---|---|---|---|---|---|
| 1.05 m | 1.40 m | 1.75 m | 2.10 m | 2.45 m | 2.80 m | 3.15 m | 3.50 m | ||
| 30 mm | ▲ | 2.52 | 1.53 | 0.96 | 0.67 | 0.50 | 0.40 | 0.33 | — |
| ▼ | 1.86 | 1.10 | 0.73 | 0.51 | 0.37 | — | — | — | |
| 40 mm | ▲ | 2.69 | 1.68 | 1.07 | 0.73 | 0.54 | 0.43 | 0.35 | — |
| ▼ | 1.86 | 1.10 | 0.73 | 0.51 | 0.37 | — | — | — | |
| 50 mm | ▲ | 2.86 | 1.85 | 1.20 | 0.82 | 0.63 | 0.50 | 0.40 | — |
| ▼ | 1.86 | 1.10 | 0.73 | 0.51 | 0.37 | — | — | — | |
Swipe the table
| Thickness | Load | Permissible load (kN/m²) by distance between supports L (m) | |||||||
|---|---|---|---|---|---|---|---|---|---|
| 1.05 m | 1.40 m | 1.75 m | 2.10 m | 2.45 m | 2.80 m | 3.15 m | 3.50 m | ||
| 30 mm | ▲ | 2.52 | 1.55 | 1.08 | 0.81 | 0.64 | 0.53 | 0.44 | 0.38 |
| ▼ | 1.86 | 1.10 | 0.73 | 0.51 | 0.38 | — | — | — | |
| 40 mm | ▲ | 2.69 | 1.70 | 1.21 | 0.93 | 0.74 | 0.61 | 0.51 | 0.44 |
| ▼ | 1.98 | 1.21 | 0.82 | 0.59 | 0.44 | 0.33 | — | — | |
| 50 mm | ▲ | 2.87 | 1.86 | 1.35 | 1.05 | 0.84 | 0.70 | 0.59 | 0.51 |
| ▼ | 2.11 | 1.32 | 0.92 | 0.67 | 0.51 | 0.39 | 0.30 | — | |
Swipe the table
| Thickness | Load | Permissible load (kN/m²) by distance between supports L (m) | |||||||
|---|---|---|---|---|---|---|---|---|---|
| 1.05 m | 1.40 m | 1.75 m | 2.10 m | 2.45 m | 2.80 m | 3.15 m | 3.50 m | ||
| 30 mm | ▲ | 2.52 | 1.54 | 0.97 | 0.68 | 0.50 | 0.40 | 0.33 | — |
| ▼ | 1.86 | 1.10 | 0.73 | 0.51 | 0.38 | — | — | — | |
| 40 mm | ▲ | 2.69 | 1.69 | 1.08 | 0.73 | 0.54 | 0.43 | 0.35 | — |
| ▼ | 1.98 | 1.21 | 0.82 | 0.59 | 0.44 | 0.33 | — | — | |
| 50 mm | ▲ | 2.87 | 1.86 | 1.21 | 0.82 | 0.63 | 0.50 | 0.40 | 0.30 |
| ▼ | 2.11 | 1.32 | 0.92 | 0.67 | 0.51 | 0.39 | 0.30 | — | |
TECHNICAL DATA SHEET
Download the complete technical data sheet for the RAL 8004 Tile-Effect Sandwich Panel to consult dimensions, thicknesses, modulation, thermal performance, weights, colors, finishes, and load tables.
The document should be used as a technical reference in conjunction with the specific conditions of each project.
QUESTIONS
It is an insulating roof panel with a geometry inspired by traditional tiles and a textured exterior finish. The RAL 8004 reference corresponds to the Tile Red color.
The minimum slope indicated in the technical data sheet is 10%. The project must also consider the geometry, junctions, flashings, and climatic conditions of the site.
The technical documentation includes thicknesses of 30, 40, and 50 mm, with an indicated tolerance of ±2 mm.
The declared thermal transmittance is 0.45 W/m²·K for 30 mm, 0.37 W/m²·K for 40 mm, and 0.31 W/m²·K for 50 mm.
Manufacturing lengths range from 2.10 to 14.00 m in multiples of 0.35 m. The maximum recommended length indicated in the data sheet is 8.05 m.
In addition to RAL 8004 Tile Red, the data sheet includes RAL 8023 Light Tile Red, RAL 9005 Jet Black, and various aged or decorative finishes. For the interior face, RAL 9010 Pure White and textured wood finish are included.
FLASHINGS FOR TILE PANEL
LATEST ARTICLES
Explore content on panel selection, insulation, installation, maintenance, refurbishment and real-world applications.
YOU MAY ALSO BE INTERESTED IN
ON-SITE SERVICE
We quote for new builds, refurbishment, roof and facade replacement, flashing installation, and work with sheet metal or skylights.
The quote depends on geometry, height, access, auxiliary equipment, location, fixings and junctions the job must resolve.