info@starmodul.com

E-mail de contacto

973 228 164 / 683 442 608

Teléfono de soporte

PANEL SANDWICH · CONFIGURACIÓN Y PRESUPUESTO

Facade Sandwich Panel · Smooth

Configura tu panel

Selecciona las opciones disponibles. Te prepararemos el precio según medidas, cantidad, transporte y montaje.

Fabricación a medida

Asesoramiento técnico

Transporte a obra

Montaje especializado

PRODUCT DESCRIPTION

Smooth facade sandwich panel

Description

The smooth facade sandwich panel is an insulating panel for building facades with hidden fixing. It is composed of two profiled metal sheets bonded to a rigid core of polyurethane (PUR) or polyisocyanurate (PIR).

The smooth version offers a continuous, clean outer surface, whilst the concealed joint system prevents the main fixings from being visible on the facade. It is a solution particularly suited when a uniform aesthetic and an insulated enclosure are required.

It is manufactured in thicknesses of 40, 50, 60, 80 and 100 mm, with useful widths of 1,000 or 1,080 mm. The stated manufacturing length is 4.00 to 14.00 m, with 8.00 m as the maximum recommended length.

The product is manufactured to EN 14509. The PUR or PIR core has a declared thermal conductivity of 0.0207 W/m·K and a density of 40 kg/m³.

Characteristics

Application

Insulating panel intended for building facades with hidden fixing. The choice of thickness, spacing between supports and sheet configuration must be verified in accordance with the actual loads and conditions of the project.

Smooth finish

The smooth outer face provides a visually continuous surface. The technical documentation also includes microprofiled and ribbed variants within the same facade panel family.

Dimensions

Thicknesses40, 50, 60, 80 and 100 mm ±2 mm
Useful width1,000 or 1,080 mm ±2 mm
Manufacturing length4.00 – 14.00 m ±10 mm
Maximum recommended length8.00 m

Metal substrate

  • Steel sheet grade S250GD to EN 10346.
  • Coated coils with organic coating to EN 10169+A1.
  • Available sheet thicknesses: 0.5 and 0.6 mm.

Insulating core

  • Polyurethane (PUR) or polyisocyanurate (PIR).
  • Thermal conductivity: 0.0207 W/m·K.
  • Density: 40 kg/m³.
  • PUR: B-s2,d0.
  • PIR: B-s2,d0.
  • High-performance PIR: B-s1,d0.

Coatings and colours

The stated standard finish is 25 µm polyester paint. Special 55 µm coatings and 35 µm PVDF finish may also be considered subject to availability.

The stated range includes RAL 9010, RAL 9006, RAL 9004, RAL 7022, RAL 7016, RAL 7012, RAL 6005, RAL 5010, RAL 3009 and RAL 1015.

The datasheet also includes special textured finishes for facade applications.

Colours shown on screen are indicative. When the shade is critical, a real sample must be checked before confirming the order.

Installation

Installation of the smooth facade sandwich panel with hidden fixing must be carried out on a correctly dimensioned and plumb substructure. The joint geometry allows the main fixing to be concealed and maintains a facade with a continuous appearance.

  • Check modulation and spacing between supports according to the wind loads of the project.
  • Position the panels maintaining alignment and plumb.
  • Use fixings suitable for the support and the panel thickness.
  • Execute the joint correctly to maintain the hidden fixing.
  • Resolve corners, copings, plinths, openings and junctions with suitable trims.
  • Avoid damaging the smooth surface during handling and assembly.

Important: admissible spans must be checked using the load tables and the actual conditions of each facade.

DECLARED PERFORMANCE

Insulation, weight and technical data

Technical data

Main characteristics

ConfigurationSmooth facade panel with hidden fixing
Useful width1,000 / 1,080 mm ±2 mm
Total thickness40 / 50 / 60 / 80 / 100 mm
Steel sheetS250GD · EN 10346
Sheet thicknesses0.5 / 0.6 mm
CorePUR or PIR
Core density40 kg/m³
Thermal conductivity0.0207 W/m·K
ApplicationBuilding facades
Manufacturing standardEN 14509

Thermal insulation and weight

Thickness40 mm50 mm60 mm80 mm100 mm
U-value (W/m²·K)0,560,420,340,250,20
Weight 0.5/0.4 (kg/m²)8,58,99,39,710,1
Weight 0.6/0.4 (kg/m²)9,910,310,711,111,5

Load tables for smooth facade panel

The following tables reproduce as actual HTML tables the values declared in the technical datasheet. Loads are expressed in kN/m² and spans in metres.

External suction and external pressure are differentiated for sheets 0.5/0.4 and 0.6/0.4, both in single-span and multi-span conditions.

Sheet 0.5/0.4 · single span

ThicknessLoad1.50 m1.75 m2.00 m2.25 m2.50 m2.75 m3.00 m3.25 m3.50 m3.75 m4.00 m4.25 m4.50 m4.75 m5.00 m
40 mmSuction2,241,621,180,800,50——————————
40 mmPressure2,241,621,180,800,50——————————
50 mmSuction3,362,511,901,451,120,840,580,39———————
50 mmPressure3,362,511,901,451,120,840,580,39———————
60 mmSuction4,393,362,572,031,641,311,050,840,620,450,32————
60 mmPressure4,393,462,682,091,651,311,050,840,620,450,32————
80 mmSuction5,894,553,492,752,231,841,551,321,140,990,870,770,640,510,40
80 mmPressure5,895,054,363,502,842,321,911,581,321,100,920,780,640,510,40
100 mmSuction6,325,424,403,482,822,331,961,671,441,251,100,970,870,780,70
100 mmPressure6,325,424,744,213,783,122,622,241,931,681,481,281,100,950,82

Sheet 0.5/0.4 · multi-span

ThicknessLoad1.50 m1.75 m2.00 m2.25 m2.50 m2.75 m3.00 m3.25 m3.50 m3.75 m4.00 m4.25 m4.50 m4.75 m5.00 m
40 mmSuction2,832,161,651,311,060,880,740,630,540,470,410,370,33——
40 mmPressure2,341,901,571,311,100,930,790,680,580,500,440,380,33——
50 mmSuction3,122,672,111,671,351,120,940,800,690,600,530,470,420,370,34
50 mmPressure3,122,672,342,081,811,501,261,070,930,810,710,630,550,480,43
60 mmSuction3,332,862,502,031,641,361,140,970,840,730,640,570,510,460,41
60 mmPressure3,332,862,502,222,001,821,531,311,130,980,860,760,680,610,54
80 mmSuction3,763,222,822,512,231,841,551,321,140,990,870,770,690,620,56
80 mmPressure3,763,222,822,512,252,051,881,731,531,331,171,040,920,830,75
100 mmSuction4,183,593,142,792,512,281,961,671,441,251,100,970,870,780,70
100 mmPressure4,183,593,142,792,512,282,091,931,791,671,481,311,171,050,94

Sheet 0.6/0.4 · single span

ThicknessLoad1.50 m1.75 m2.00 m2.25 m2.50 m2.75 m3.00 m3.25 m3.50 m3.75 m4.00 m4.25 m4.50 m4.75 m5.00 m
40 mmSuction2,301,671,230,830,520,30—————————
40 mmPressure2,301,671,230,830,520,30—————————
50 mmSuction3,442,581,961,511,170,880,610,41———————
50 mmPressure3,442,581,961,511,170,880,610,41———————
60 mmSuction4,393,352,572,031,641,361,100,890,660,480,34————
60 mmPressure4,393,552,762,171,721,371,100,890,660,480,34————
80 mmSuction5,894,553,482,752,231,841,551,321,140,990,870,770,680,540,43
80 mmPressure5,895,054,423,612,942,411,991,661,381,160,980,820,680,540,43
100 mmSuction6,325,414,403,482,822,331,961,671,441,251,100,970,870,780,70
100 mmPressure6,325,414,744,213,793,453,002,532,151,831,571,341,161,000,87

Sheet 0.6/0.4 · multi-span

ThicknessLoad1.50 m1.75 m2.00 m2.25 m2.50 m2.75 m3.00 m3.25 m3.50 m3.75 m4.00 m4.25 m4.50 m4.75 m5.00 m
40 mmSuction2,822,161,651,311,060,870,730,630,540,470,410,370,33——
40 mmPressure2,822,371,931,601,341,130,960,820,670,550,470,400,350,30—
50 mmSuction3,122,672,111,671,351,120,940,800,690,600,530,470,420,370,34
50 mmPressure3,122,672,342,081,871,641,411,150,930,770,640,550,470,410,36
60 mmSuction3,332,852,502,031,641,361,140,970,840,730,640,570,510,460,41
60 mmPressure3,332,852,502,222,001,821,671,501,221,000,840,710,610,530,46
80 mmSuction3,763,222,822,502,231,841,551,321,140,990,870,770,690,620,56
80 mmPressure3,763,222,822,502,252,051,881,731,611,501,291,080,920,790,69
100 mmSuction4,183,593,142,792,512,281,961,671,441,251,100,970,870,780,70
100 mmPressure4,183,593,142,792,512,282,091,931,791,671,571,481,281,090,94

TECHNICAL DATASHEET

Technical datasheet for smooth facade sandwich panel

Consult the technical datasheet with dimensions, materials, thermal insulation, weights, finishes and load tables for the panel.

TECHNICAL IMAGES

Details of the smooth facade panel

QUESTIONS

Frequently asked questions about smooth facade sandwich panel

It is an insulating panel for facades with a smooth-finish outer face and a PUR or PIR insulating core.

No. This solution uses a hidden fixing system, so that the main fixing is protected by the joint geometry.

The technical datasheet includes 40, 50, 60, 80 and 100 mm.

The declared widths are 1,000 and 1,080 mm, with a tolerance of ±2 mm.

The declared U-value ranges from 0.56 W/m²·K at 40 mm to 0.20 W/m²·K at 100 mm.

No. The values from the technical datasheet have been converted into actual HTML tables to facilitate consultation, reading and indexing.

FACADE TRIMS

Trims for smooth facade sandwich panel

You may also like…

LATEST ARTICLES

Guides and advice on sandwich panel

Consult content on panel selection, insulation, installation, maintenance, refurbishment and real applications.

TAMBIÉN TE PUEDE INTERESAR

Productos relacionados

SERVICIO DE OBRA

Equipo especializado para el montaje de panel sandwich

Valoramos obra nueva, rehabilitación, sustitución de cubiertas y fachadas, colocación de rematería y trabajos con chapa o lucernarios.

El presupuesto depende de la geometría, altura, accesos, medios auxiliares, ubicación, fijaciones y encuentros que deba resolver la obra.

PRESUPUESTO PERSONALIZADO

Solicita precio de panel sandwich

Indica tipo de panel, superficie, espesor, localidad y si necesitas suministro o montaje. Revisaremos los datos para preparar una propuesta ajustada.

SOLICITUD RÁPIDA

Cuéntanos qué necesitas

Completa los datos principales y prepararemos una propuesta ajustada a tu proyecto.

Datos de contacto¿Con quién debemos hablar?
Datos del proyectoTipo de panel, servicio y cantidades.
Detalles y documentaciónAñade la información necesaria para valorar correctamente.