
Contact Email
Support Phone Number
PERSONALISED QUOTE
Tell us the panel type, area, thickness, location and whether you need supply only or installation. We’ll review the details to prepare a tailored proposal.
QUICK REQUEST
Complete the main details and we will prepare a proposal tailored to your project.
PRODUCT DESCRIPTION
The sandwich panel for farms with joint cover is designed for agricultural roofs that require protection against corrosive environments and hidden fixing. The joint cover conceals the fixing system and improves the roof’s external continuity.
This agropanel with joint cover combines profiled outer steel sheet, PUR insulating core, and a reinforced polyester inner face with fibreglass. It is also identified as a agricultural sandwich panel with joint cover or livestock panel with joint cover.
It is suitable for farms and other facilities exposed to humidity, vapours or corrosive agents where an insulating, durable roofing solution is required.
See all sandwich panel for farms models and compare the different agropanel solutions.
Roof panel intended for agricultural facilities or constructions exposed to corrosive environments. The inner fiberglass-reinforced polyester face is designed to improve performance against biochemical corrosion.
| Thicknesses | 30, 40, 50, 60, 80, and 100 mm ±2 mm |
|---|---|
| Effective width | 1,000 mm ±2 mm |
| Length | 4.00 – 14.00 m ±10 mm |
| Maximum recommended length | 12.00 m |

The outer sheet features 25 µm polyester paint as a standard finish. The technical documentation also includes special coatings of 55 µm and 35 µm PVDF.
The represented range includes RAL 9010, 9006, 9004, 7022, 7016, 7012, 6005, 5010, 3009, and 1015.
Screen colors are indicative; when the shade is critical, it must be confirmed with a physical sample.
Installation must be carried out on a correctly dimensioned structure, selecting fasteners and support spacing according to the project’s actual loads.
Important: the current technical documentation consulted does not specify a minimum slope in the data sheet; it must be defined according to the project, overlaps, and watertightness conditions.
DECLARED PERFORMANCE
| Configuration | Agricultural roof panel with hidden fixing under a joint cover |
|---|---|
| Tolerances | According to EN 14509 |
| Thicknesses | 30, 40, 50, 60, 80 and 100 mm (±2 mm) |
| Useful width | 1,000 mm (±2 mm) |
| Length | 4.00 to 14.00 m, made to measure (±10 mm) · recommended up to 12.00 m |
| Rib | 30 mm high, every 333 mm · 65 mm at the base and 34 mm at the crest |
| Outer sheet | S250GD steel (EN 10346), pre-painted (EN 10169+A1) |
| Sheet thicknesses | 0.4 / 0.5 / 0.6 / 0.7 mm |
| Inner face | Fibreglass-reinforced polyester, resistant to biochemical corrosion |
| Core | Polyurethane (PUR) · 40 kg/m³ |
| Thermal conductivity | λ = 0.0207 W/m·K |
| Reaction to fire | PUR: not certified |
| Outer coating | 25 µm polyester · special: 55 µm (RC5) and 35 µm PVDF |
| Colours | RAL 9010, 9006, 9004, 7022, 7016, 7012, 7024, 6005, 5010, 3009 and 1015 · white polyester inner face · other RAL colours on request |
| Thickness | 30 mm | 40 mm | 50 mm | 60 mm | 80 mm | 100 mm |
|---|---|---|---|---|---|---|
| U-value (W/m²·K) | 0,63 | 0,48 | 0,39 | 0,33 | 0,25 | 0,20 |
| Weight, 0.5 sheet (kg/m²) | 5,9 | 6,3 | 6,7 | 7,1 | 7,9 | 8,7 |
Loads from the technical data sheet in kN/m² according to the span between supports (in metres).
The calculation table in the data sheet includes sheets of 0.4 / 0.5 / 0.6 mm. Although the range also supports 0.7 mm sheet, the consulted data sheet does not publish load values for 0.7 mm.
| Sheet | Load | 1.00 m | 1.25 m | 1.50 m | 1.75 m | 2.00 m | 2.25 m | 2.50 m | 2.75 m | 3.00 m | 3.25 m | 3.50 m |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0.4 mm | Upward | 1,31 | 0,85 | 0,60 | 0,44 | 0,33 | — | — | — | — | — | — |
| 0.4 mm | Downward | 1,34 | 0,92 | 0,63 | 0,40 | — | — | — | — | — | — | — |
| 0.5 mm | Upward | 1,65 | 1,08 | 0,76 | 0,56 | 0,43 | 0,34 | — | — | — | — | — |
| 0.5 mm | Downward | 1,89 | 1,28 | 0,88 | 0,58 | — | — | — | — | — | — | — |
| 0.6 mm | Upward | 2,19 | 1,44 | 1,02 | 0,76 | 0,59 | 0,46 | 0,37 | 0,31 | — | — | — |
| 0.6 mm | Downward | 2,81 | 1,89 | 1,30 | 0,87 | 0,47 | — | — | — | — | — | — |
| Sheet | Load | 1.00 m | 1.25 m | 1.50 m | 1.75 m | 2.00 m | 2.25 m | 2.50 m | 2.75 m | 3.00 m | 3.25 m | 3.50 m |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0.4 mm | Upward | 1,06 | 0,84 | 0,63 | 0,45 | 0,34 | — | — | — | — | — | — |
| 0.4 mm | Downward | 1,06 | 0,84 | 0,60 | 0,44 | 0,33 | — | — | — | — | — | — |
| 0.5 mm | Upward | 1,50 | 1,19 | 0,88 | 0,64 | 0,48 | 0,37 | — | — | — | — | — |
| 0.5 mm | Downward | 1,50 | 1,08 | 0,76 | 0,56 | 0,43 | 0,34 | — | — | — | — | — |
| 0.6 mm | Upward | 2,24 | 1,78 | 1,30 | 0,95 | 0,71 | 0,56 | 0,44 | 0,36 | — | — | — |
| 0.6 mm | Downward | 2,19 | 1,44 | 1,02 | 0,76 | 0,59 | 0,46 | 0,37 | 0,31 | — | — | — |
TECHNICAL DATA SHEET
Technical data sheet with dimensions, materials, insulation, weights and load tables.
QUESTIONS
It is a roofing agropanel with a hidden fixing system via a joint cover, PUR core and reinforced polyester inner face.
The joint cover conceals the fixing and protects the external junction, providing continuity and watertightness to the roofing system.
Yes. The technical documentation specifies it for agricultural facilities and corrosive environments.
The technical datasheet specifies a polyurethane PUR core.
Yes. It is one of the main applications of this type of livestock panel or agropanel.
ROOF FLASHINGS
Complete the roof with compatible flashings and accessories. You can also view all sandwich panel for farms models.
LATEST ARTICLES
Explore content on panel selection, insulation, installation, maintenance, refurbishment and real-world applications.
YOU MAY ALSO BE INTERESTED IN
ON-SITE SERVICE
We quote for new builds, refurbishment, roof and facade replacement, flashing installation, and work with sheet metal or skylights.
The quote depends on geometry, height, access, auxiliary equipment, location, fixings and junctions the job must resolve.