PRODUCT DESCRIPTION
The facade sandwich panel with hidden fastening is an insulating panel for vertical enclosures with concealed fixing. It consists of two profiled metal sheets joined to a rigid core of polyurethane (PUR) or polyisocyanurate (PIR).
The joint between panels conceals the fixing screws, allowing for a continuous and visually cleaner facade. The panel is available with a micro-profiled, ribbed, or smooth exterior face, so it can adapt to different architectural and industrial solutions.
It is manufactured in thicknesses of 40, 50, 60, 80, and 100 mm, with effective widths of 1,000 or 1,080 mm. The indicated manufacturing length is from 4.00 to 14.00 m, with 8.00 m as the maximum recommended length.
The product is manufactured according to EN 14509. The PUR or PIR core has a declared thermal conductivity of 0.0207 W/m·K and a density of 40 kg/m³.
Insulating panel intended for building facades. Its hidden fastening system allows the screws to be concealed in the joint between panels. The choice of thickness and support spacing must be verified according to wind loads and the actual conditions of each project.
| Thicknesses | 40, 50, 60, 80, and 100 mm ±2 mm |
|---|---|
| Effective Width | 1,000 or 1,080 mm ±2 mm |
| Manufacturing Length | 4.00 – 14.00 m ±10 mm |
| Maximum Recommended Length | 8.00 m |
The standard finish indicated in the technical documentation is 25 µm polyester paint. Special coatings of 55 µm and PVDF finish of 35 µm may also be considered, subject to availability and supply conditions.
Available colours: RAL 9010, RAL 9006, RAL 7016, RAL 7012, RAL 7022, RAL 7024, RAL 6005, RAL 5019, RAL 3009 and RAL 1015, with the inner face in RAL 9010. Other RAL colours on request.
The colors shown on screen are indicative. When the shade is critical, a real sample should be checked before confirming the order.
The installation of the facade sandwich panel with hidden fastening must be carried out on a correctly sized and plumbed substructure. The fastening is concealed in the joint between panels, so the positioning and closing of each joint must be executed with precision.
Important: permissible spans must be checked using load tables and the actual conditions of each facade.
DECLARED PERFORMANCE
| Configuration | Insulated facade panel with hidden fixing in the joint |
|---|---|
| Manufacturing standard | EN 14509 · performance assessed under system 1 |
| Application | Building facades |
| Thicknesses | 40, 50, 60, 80 and 100 mm (±2 mm) |
| Useful width | 1,000 or 1,080 mm (±2 mm) |
| Length | 4.00 to 14.00 m, made to measure (±10 mm) · recommended up to 8.00 m |
| Outer face | Micro-profiled, ribbed or smooth |
| Steel sheet | S250GD (EN 10346), pre-painted (EN 10169+A1) |
| Sheet thicknesses | Outer 0.5 or 0.6 mm · inner 0.4 mm |
| Core | PUR or PIR · 40 kg/m³ |
| Thermal conductivity | λ = 0.0207 W/m·K |
| Reaction to fire | PIR: B-s2,d0 · high-performance PIR: B-s1,d0 · PUR: not certified |
| Coating | 25 µm polyester · subject to availability: 55 µm (RC5) and 35 µm PVDF |
| Colours | RAL 9010, 9006, 7016, 7012, 7022, 7024, 6005, 5019, 3009 and 1015 · inner face RAL 9010 · other RAL colours on request |
| Thickness | U-value | Weight 0.5/0.4 | Weight 0.6/0.4 |
|---|---|---|---|
| 40 mm | 0.56 W/m²·K | 8.5 kg/m² | 9.9 kg/m² |
| 50 mm | 0.42 | 8.9 | 10.3 |
| 60 mm | 0.34 | 9.3 | 10.7 |
| 80 mm | 0.25 | 9.7 | 11.1 |
| 100 mm | 0.20 | 10.1 | 11.5 |
| Thickness | U-value (W/m²·K) | Weight 0.5/0.4 (kg/m²) | Weight 0.6/0.4 (kg/m²) |
|---|---|---|---|
| 40 mm | 0.56 | 8.5 | 9.9 |
| 50 mm | 0.42 | 8.9 | 10.3 |
| 60 mm | 0.34 | 9.3 | 10.7 |
| 80 mm | 0.25 | 9.7 | 11.1 |
| 100 mm | 0.20 | 10.1 | 11.5 |
The technical data sheet includes tables of uniformly distributed loads for spans from 1.50 to 5.00 m, differentiating exterior suction and exterior pressure, single or multiple support, and sheet configurations of 0.5/0.4 and 0.6/0.4 mm.
These tables are a technical reference and do not replace project calculations. The spacing between supports must be verified according to wind pressure and suction, building height, location, modulation, and actual facade conditions.
Swipe the table
| Thickness | Load | Permissible load (kN/m²) by distance between supports L (m) | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.50 m | 1.75 m | 2.00 m | 2.25 m | 2.50 m | 2.75 m | 3.00 m | 3.25 m | 3.50 m | 3.75 m | 4.00 m | 4.25 m | 4.50 m | 4.75 m | 5.00 m | ||
| 40 mm | ◄ | 2.24 | 1.62 | 1.18 | 0.80 | 0.50 | — | — | — | — | — | — | — | — | — | — |
| ► | 2.24 | 1.62 | 1.18 | 0.80 | 0.50 | — | — | — | — | — | — | — | — | — | — | |
| 50 mm | ◄ | 3.36 | 2.51 | 1.90 | 1.45 | 1.12 | 0.84 | 0.58 | 0.39 | — | — | — | — | — | — | — |
| ► | 3.36 | 2.51 | 1.90 | 1.45 | 1.12 | 0.84 | 0.58 | 0.39 | — | — | — | — | — | — | — | |
| 60 mm | ◄ | 4.39 | 3.36 | 2.57 | 2.03 | 1.64 | 1.31 | 1.05 | 0.84 | 0.62 | 0.45 | 0.32 | — | — | — | — |
| ► | 4.39 | 3.46 | 2.68 | 2.09 | 1.65 | 1.31 | 1.05 | 0.84 | 0.62 | 0.45 | 0.32 | — | — | — | — | |
| 80 mm | ◄ | 5.89 | 4.55 | 3.49 | 2.75 | 2.23 | 1.84 | 1.55 | 1.32 | 1.14 | 0.99 | 0.87 | 0.77 | 0.64 | 0.51 | 0.40 |
| ► | 5.89 | 5.05 | 4.36 | 3.50 | 2.84 | 2.32 | 1.91 | 1.58 | 1.32 | 1.10 | 0.92 | 0.78 | 0.64 | 0.51 | 0.40 | |
| 100 mm | ◄ | 6.32 | 5.42 | 4.40 | 3.48 | 2.82 | 2.33 | 1.96 | 1.67 | 1.44 | 1.25 | 1.10 | 0.97 | 0.87 | 0.78 | 0.70 |
| ► | 6.32 | 5.42 | 4.74 | 4.21 | 3.78 | 3.12 | 2.62 | 2.24 | 1.93 | 1.68 | 1.48 | 1.28 | 1.10 | 0.95 | 0.82 | |
Swipe the table
| Thickness | Load | Permissible load (kN/m²) by distance between supports L (m) | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.50 m | 1.75 m | 2.00 m | 2.25 m | 2.50 m | 2.75 m | 3.00 m | 3.25 m | 3.50 m | 3.75 m | 4.00 m | 4.25 m | 4.50 m | 4.75 m | 5.00 m | ||
| 40 mm | ◄ | 2.83 | 2.16 | 1.65 | 1.31 | 1.06 | 0.88 | 0.74 | 0.63 | 0.54 | 0.47 | 0.41 | 0.37 | 0.33 | — | — |
| ► | — | 2.34 | 1.90 | 1.57 | 1.31 | 1.10 | 0.93 | 0.79 | 0.68 | 0.58 | 0.50 | 0.44 | 0.38 | 0.33 | — | |
| 50 mm | ◄ | 3.12 | 2.67 | 2.11 | 1.67 | 1.35 | 1.12 | 0.94 | 0.80 | 0.69 | 0.60 | 0.53 | 0.47 | 0.42 | 0.37 | 0.34 |
| ► | 3.12 | 2.67 | 2.34 | 2.08 | 1.81 | 1.50 | 1.26 | 1.07 | 0.93 | 0.81 | 0.71 | 0.63 | 0.55 | 0.48 | 0.43 | |
| 60 mm | ◄ | 3.33 | 2.86 | 2.50 | 2.03 | 1.64 | 1.36 | 1.14 | 0.97 | 0.84 | 0.73 | 0.64 | 0.57 | 0.51 | 0.46 | 0.41 |
| ► | 3.33 | 2.86 | 2.50 | 2.22 | 2.00 | 1.82 | 1.53 | 1.31 | 1.13 | 0.98 | 0.86 | 0.76 | 0.68 | 0.61 | 0.54 | |
| 80 mm | ◄ | 3.76 | 3.22 | 2.82 | 2.51 | 2.23 | 1.84 | 1.55 | 1.32 | 1.14 | 0.99 | 0.87 | 0.77 | 0.69 | 0.62 | 0.56 |
| ► | 3.76 | 3.22 | 2.82 | 2.51 | 2.25 | 2.05 | 1.88 | 1.73 | 1.53 | 1.33 | 1.17 | 1.04 | 0.92 | 0.83 | 0.75 | |
| 100 mm | ◄ | 4.18 | 3.59 | 3.14 | 2.79 | 2.51 | 2.28 | 1.96 | 1.67 | 1.44 | 1.25 | 1.10 | 0.97 | 0.87 | 0.78 | 0.70 |
| ► | 4.18 | 3.59 | 3.14 | 2.79 | 2.51 | 2.28 | 2.09 | 1.93 | 1.79 | 1.67 | 1.48 | 1.31 | 1.17 | 1.05 | 0.94 | |
Swipe the table
| Thickness | Load | Permissible load (kN/m²) by distance between supports L (m) | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.50 m | 1.75 m | 2.00 m | 2.25 m | 2.50 m | 2.75 m | 3.00 m | 3.25 m | 3.50 m | 3.75 m | 4.00 m | 4.25 m | 4.50 m | 4.75 m | 5.00 m | ||
| 40 mm | ◄ | 2.30 | 1.67 | 1.23 | 0.83 | 0.52 | 0.30 | — | — | — | — | — | — | — | — | — |
| ► | 2.30 | 1.67 | 1.23 | 0.83 | 0.52 | 0.30 | — | — | — | — | — | — | — | — | — | |
| 50 mm | ◄ | 3.44 | 2.58 | 1.96 | 1.51 | 1.17 | 0.88 | 0.61 | 0.41 | — | — | — | — | — | — | — |
| ► | 3.44 | 2.58 | 1.96 | 1.51 | 1.17 | 0.88 | 0.61 | 0.41 | — | — | — | — | — | — | — | |
| 60 mm | ◄ | 4.39 | 3.35 | 2.57 | 2.03 | 1.64 | 1.36 | 1.10 | 0.89 | 0.66 | 0.48 | 0.34 | — | — | — | — |
| ► | 4.39 | 3.55 | 2.76 | 2.17 | 1.72 | 1.37 | 1.10 | 0.89 | 0.66 | 0.48 | 0.34 | — | — | — | — | |
| 80 mm | ◄ | 5.89 | 4.55 | 3.48 | 2.75 | 2.23 | 1.84 | 1.55 | 1.32 | 1.14 | 0.99 | 0.87 | 0.77 | 0.68 | 0.54 | 0.43 |
| ► | 5.89 | 5.05 | 4.42 | 3.61 | 2.94 | 2.41 | 1.99 | 1.66 | 1.38 | 1.16 | 0.98 | 0.82 | 0.68 | 0.54 | 0.43 | |
| 100 mm | ◄ | 6.32 | 5.41 | 4.40 | 3.48 | 2.82 | 2.33 | 1.96 | 1.67 | 1.44 | 1.25 | 1.10 | 0.97 | 0.87 | 0.78 | 0.70 |
| ► | 6.32 | 5.41 | 4.74 | 4.21 | 3.79 | 3.45 | 3.00 | 2.53 | 2.15 | 1.83 | 1.57 | 1.34 | 1.16 | 1.00 | 0.87 | |
Swipe the table
| Thickness | Load | Permissible load (kN/m²) by distance between supports L (m) | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.50 m | 1.75 m | 2.00 m | 2.25 m | 2.50 m | 2.75 m | 3.00 m | 3.25 m | 3.50 m | 3.75 m | 4.00 m | 4.25 m | 4.50 m | 4.75 m | 5.00 m | ||
| 40 mm | ◄ | 2.82 | 2.16 | 1.65 | 1.31 | 1.06 | 0.87 | 0.73 | 0.63 | 0.54 | 0.47 | 0.41 | 0.37 | 0.33 | — | — |
| ► | 2.82 | 2.37 | 1.93 | 1.60 | 1.34 | 1.13 | 0.96 | 0.82 | 0.67 | 0.55 | 0.47 | 0.40 | 0.35 | 0.30 | — | |
| 50 mm | ◄ | 3.12 | 2.67 | 2.11 | 1.67 | 1.35 | 1.12 | 0.94 | 0.80 | 0.69 | 0.60 | 0.53 | 0.47 | 0.42 | 0.37 | 0.34 |
| ► | 3.12 | 2.67 | 2.34 | 2.08 | 1.87 | 1.64 | 1.41 | 1.15 | 0.93 | 0.77 | 0.64 | 0.55 | 0.47 | 0.41 | 0.36 | |
| 60 mm | ◄ | 3.33 | 2.85 | 2.50 | 2.03 | 1.64 | 1.36 | 1.14 | 0.97 | 0.84 | 0.73 | 0.64 | 0.57 | 0.51 | 0.46 | 0.41 |
| ► | 3.33 | 2.85 | 2.50 | 2.22 | 2.00 | 1.82 | 1.67 | 1.50 | 1.22 | 1.00 | 0.84 | 0.71 | 0.61 | 0.53 | 0.46 | |
| 80 mm | ◄ | 3.76 | 3.22 | 2.82 | 2.50 | 2.23 | 1.84 | 1.55 | 1.32 | 1.14 | 0.99 | 0.87 | 0.77 | 0.69 | 0.62 | 0.56 |
| ► | 3.76 | 3.22 | 2.82 | 2.50 | 2.25 | 2.05 | 1.88 | 1.73 | 1.61 | 1.50 | 1.29 | 1.08 | 0.92 | 0.79 | 0.69 | |
| 100 mm | ◄ | 4.18 | 3.59 | 3.14 | 2.79 | 2.51 | 2.28 | 1.96 | 1.67 | 1.44 | 1.25 | 1.10 | 0.97 | 0.87 | 0.78 | 0.70 |
| ► | 4.18 | 3.59 | 3.14 | 2.79 | 2.51 | 2.28 | 2.09 | 1.93 | 1.79 | 1.67 | 1.57 | 1.48 | 1.28 | 1.09 | 0.94 | |
TECHNICAL DATA SHEET
Download the complete technical data sheet for the facade sandwich panel with hidden fastening to consult finishes, dimensions, thicknesses, hidden fastening, thermal performance, weights, colors, and load tables.
The document should be used as a technical reference along with the specific conditions of each project.
QUESTIONS
It is an insulating panel for facades whose fastening is concealed in the joint between panels. It consists of two metal sheets and a PUR or PIR insulating core.
The technical data sheet includes three exterior finishes: micro-profiled, ribbed, and smooth. The choice depends on the aesthetic and design of the facade.
Thicknesses of 40, 50, 60, 80, and 100 mm are available, with an indicated tolerance of ±2 mm.
The declared thermal transmittance ranges from 0.56 W/m²·K at 40 mm to 0.20 W/m²·K at 100 mm. The declared thermal conductivity of the PUR and PIR core is 0.0207 W/m·K.
The technical documentation includes effective widths of 1,000 and 1,080 mm, both with a tolerance of ±2 mm.
The screws are hidden in the joint between panels, providing a more continuous and visually cleaner exterior facade.
FACADE TRIMS
LATEST ARTICLES
Consult content on panel selection, insulation, assembly, maintenance, rehabilitation, and real applications.
YOU MAY ALSO BE INTERESTED IN
ON-SITE SERVICE
We quote for new builds, refurbishment, roof and facade replacement, flashing installation, and work with sheet metal or skylights.
The quote depends on geometry, height, access, auxiliary equipment, location, fixings and junctions the job must resolve.