973 228 164 · 699 147 762

Support Phone Number

Made to measure

Technical advice

Delivery to site

Specialist installation

SANDWICH PANEL · CONFIGURATION AND QUOTE

Tile-Effect Sandwich Panel – Slate

Configure your panel

Select the available options. We will prepare the price based on dimensions, quantity, transport and installation.

PERSONALISED QUOTE

Request a price for this product

Tell us the panel type, area, thickness, location and whether you need supply only or installation. We’ll review the details to prepare a tailored proposal.

QUICK REQUEST

Tell us what you need

Complete the main details and we will prepare a proposal tailored to your project.

PRODUCT DESCRIPTION

Slate Tile Effect Sandwich Panel

Slate tile effect sandwich panel

The slate tile effect sandwich panel is an insulating roof panel whose exterior face visually reproduces the rectangular layout of traditional slate. It integrates exterior finish, insulation, and enclosure into a single prefabricated element.

The technical datasheet indicates horizontal assembly, transverse to the water drainage slope, a minimum slope of 30%, a slate step of 125 mm, and a useful width of 1,000 mm.

It is available in nominal thicknesses of 40, 50, 60, 80, 100, and 120 mm. The documentation identifies 60 mm as the standard average manufacturing thickness and recommends sealing the joint during assembly.

Characteristics of the slate effect sandwich panel

Application

Insulating panel for roofs with a slate aesthetic. Unlike conventional longitudinal roof panels, its assembly is carried out horizontally and transverse to the roof slope.

Dimensions and configuration

CharacteristicValue
Effective width1,000 mm
Slate step125 mm
Nominal thicknesses40 / 50 / 60 / 80 / 100 / 120 mm
Indicated standard thickness60 mm
Minimum slope30%
AssemblyHorizontal, transverse to the slope

Sheets

The load table for the steel/steel configuration is published with an exterior support of 0.50 mm and an interior support of 0.40 mm.

Slate finish and profiling

The exterior geometry is designed to create a visual reading similar to a slate roof, with rectangular joints and modulations. The dark finish reinforces this aesthetic and allows it to be differentiated from the traditional tile effect sandwich panel.

Technical documentation shows different profiling possibilities for the interior face, including smooth finish, profiled ribbed, mini-diamond micro-profiling, and wood-type micro-profiled batten. The availability of each combination must be confirmed when requesting a quote.

Installation of the slate tile sandwich panel

Installation must be carried out with the panels in a horizontal direction and transverse to the water fall slope. The technical datasheet establishes a minimum slope of 30%.

  • Plan the structure specifically for horizontal assembly.
  • Respect the useful width of 1,000 mm and the panel modulation.
  • The documentation recommends always sealing the joint during assembly.
  • The load table uses an effective support width of 100 mm.
  • Correctly resolve ridges, sides, eaves, and joints.

Admissible spans must be checked against the load table and the actual project conditions.

DECLARED PERFORMANCE

Technical data of the slate tile effect sandwich panel

Insulation, weight, and technical data

Nominal thickness (mm)U-value (W/m²·K)Nominal weight (kg/m²)
400.568.4
500.458.8
600.389.2
800.2810.0
1000.2310.8
1200.1911.6

Declared thermal transmittances according to UNE EN 14509 A.10. Weights correspond to the steel/steel configuration used in the load table.

Slate sandwich panel load table

Uniformly distributed admissible overloads in kg/m² for an effective support width of 100 mm. The technical datasheet limits the deflection to L/200.

Thickness (mm)1.50 m1.75 m2.00 m2.25 m2.50 m2.75 m3.00 m3.25 m3.50 m3.75 m4.00 m4.25 m4.50 m4.75 m5.00 m
40180140110857055
50230185145120100806555
6028022518515012510590756050
803602952452051751501301109580706055
10043536030025522019016514512511010085756560
120495410350300260225200175155140120110958575

Important: these values are a reference for the published configuration. The project must check wind loads, snow, maintenance, number of supports, and other applicable actions.

TECHNICAL DATA SHEET

Technical datasheet · Slate Tile Effect Sandwich Panel

Download the technical datasheet with dimensions, thicknesses, thermal transmittance, available profiles, joint detail, assembly, and load table.

TECHNICAL IMAGES

Details of the slate effect sandwich panel

QUESTIONS

Frequently asked questions about slate tile effect sandwich panel

It is an insulating roof panel whose exterior sheet visually reproduces a traditional slate roof through rectangular modulation.

The technical datasheet establishes a minimum slope of 30%.

Assembly is horizontal and transverse to the water fall slope, so the structure must be prepared for this arrangement.

The documentation covers 40, 50, 60, 80, 100, and 120 mm. The indicated standard average manufacturing thickness is 60 mm.

The useful width is 1,000 mm and the indicated slate step is 125 mm.

The declared thermal transmittance ranges from 0.56 W/m²·K at 40 mm to 0.19 W/m²·K at 120 mm.

ROOF FLASHINGS

Flashings and accessories for Slate Tile Sandwich Panel

Complete the roof with compatible flashings and accessories or consult all tile sandwich panel models.

LATEST ARTICLES

Guides and advice on sandwich panels

Explore content on panel selection, insulation, installation, maintenance, refurbishment and real-world applications.

ON-SITE SERVICE

Specialist team for sandwich panel installation

We quote for new builds, refurbishment, roof and facade replacement, flashing installation, and work with sheet metal or skylights.

The quote depends on geometry, height, access, auxiliary equipment, location, fixings and junctions the job must resolve.

Sandwich panel installation on site