973 228 164 · 699 147 762

Support Phone Number

Made to measure

Technical advice

Delivery to site

Specialist installation

SANDWICH PANEL · CONFIGURATION AND QUOTE

Facade Sandwich Panel · Exposed Fastening

Configure your panel

Select the available options. We will prepare the price based on dimensions, quantity, transport and installation.

PERSONALISED QUOTE

Request a price for this product

Tell us the panel type, area, thickness, location and whether you need supply only or installation. We’ll review the details to prepare a tailored proposal.

QUICK REQUEST

Tell us what you need

Complete the main details and we will prepare a proposal tailored to your project.

PRODUCT DESCRIPTION

Facade sandwich panel with exposed fastening

Description

The facade sandwich panel with exposed fastening is an insulating panel for walls, prefabricated structures, modular construction, and facades with visible fixing. It consists of two profiled metal sheets joined to a rigid core of polyurethane (PUR) or polyisocyanurate (PIR).

The fastening is visible on the panel, offering a simple and versatile solution for vertical enclosures. It is available with micro-profiled, ribbed, or smooth exterior face.

It is manufactured in thicknesses of 30, 40, 50, 60, 80, and 100 mm, with useful widths of 1,000 or 1,100 mm. The indicated manufacturing length is from 4.00 to 14.00 m, with 8.00 m as the maximum recommended length.

The product is manufactured according to EN 14509. The PUR or PIR core has a declared thermal conductivity of 0.0207 W/m·K and a density of 40 kg/m³.

Features

Application

Insulating panel intended for walls, prefabricated structures, modular construction, and facades with visible fixing. The choice of thickness and spacing between supports must be verified according to wind loads and the actual conditions of each project.

Exterior Finishes

  • Micro-profiled: fine relief of approximately 0.8 mm and approximate pitch of 25 mm.
  • Ribbed: rib of approximately 1.5 mm, with indicated geometry of 38/83 mm.
  • Smooth: continuous surface exterior finish.

Dimensions

Thicknesses30, 40, 50, 60, 80, and 100 mm ±2 mm
Useful Width1,000 or 1,100 mm ±2 mm
Manufacturing Length4.00 – 14.00 m ±10 mm
Maximum Recommended Length8.00 m

Metal Supports

  • S250GD steel sheet according to EN 10346.
  • Lacquered coils with organic coating according to EN 10169+A1.
  • Available sheet thicknesses: 0.4 and 0.5 mm.

Insulating Core

  • Polyurethane (PUR) or Polyisocyanurate (PIR).
  • PUR thermal conductivity: 0.0207 W/m·K.
  • PIR thermal conductivity: 0.0207 W/m·K.
  • Density: 40 kg/m³.
  • Reaction to fire according to EN 13501-1.
  • PUR: not certified.
  • PIR: B-s2,d0.
  • High-performance PIR option: B-s1,d0.

Coatings and Colors

The standard finish indicated in the technical documentation is 25 µm polyester paint. Special coatings of 55 µm and PVDF finish of 35 µm may also be considered depending on availability and supply conditions.

Available colours: RAL 9010, RAL 9006, RAL 7016, RAL 7012, RAL 7022, RAL 7024, RAL 6005, RAL 5019, RAL 3009 and RAL 1015, with the inner face in RAL 9010. Other RAL colours on request.

Colors shown on screen are indicative. When the shade is critical, a real sample should be checked before confirming the order.

Installation

The installation of the facade sandwich panel with exposed fastening must be carried out on a correctly dimensioned and plumb substructure. The fastening remains visible and is applied directly to the panel face at the points defined by the project.

  • Check modulation and spacing between supports according to project wind loads.
  • Install panels maintaining alignment and plumb.
  • Use fasteners appropriate for the support and panel thickness.
  • Correctly distribute fasteners according to loads and geometry.
  • Address corners, copings, plinths, openings, and junctions using appropriate trims.
  • Avoid damaging coatings during handling and assembly.

Important: permissible spans must be verified using load tables and the actual conditions of each facade.

DECLARED PERFORMANCE

Insulation, Weight, and Technical Data

Technical Data

Main Characteristics

ConfigurationInsulated facade panel with visible fixing through the joint
Manufacturing standardEN 14509 · performance assessed under system 1
ApplicationWalls, prefabricated buildings, modular construction and facades
Thicknesses30, 40, 50, 60, 80 and 100 mm (±2 mm)
Useful width1,000 or 1,100 mm (±2 mm)
Length4.00 to 14.00 m, made to measure (±10 mm) · recommended up to 8.00 m
Outer faceMicro-profiled, ribbed or smooth
Steel sheetS250GD (EN 10346), pre-painted (EN 10169+A1)
Sheet thicknesses0.4 / 0.4 or 0.5 / 0.5 mm (outer / inner)
CorePUR or PIR · 40 kg/m³
Thermal conductivityλ = 0.0207 W/m·K
Reaction to fireHigh-performance PIR: B-s1,d0 · PUR: not certified
Coating25 µm polyester · subject to availability: 55 µm (RC5) and 35 µm PVDF
ColoursRAL 9010, 9006, 7016, 7012, 7022, 7024, 6005, 5019, 3009 and 1015 · inner face RAL 9010 · other RAL colours on request

Thermal Insulation and Weight

ThicknessU-value TransmittanceWeight 0.4/0.4Weight 0.5/0.5
30 mm0.69 W/m²·K7.0 kg/m²8.6 kg/m²
40 mm0.517.49.0
50 mm0.407.79.4
60 mm0.348.19.8
80 mm0.25–10.2
100 mm0.20–10.6

Thermal insulation and weight

ThicknessU-value
(W/m²·K)
Weight 0.4/0.4
(kg/m²)
Weight 0.5/0.5
(kg/m²)
30 mm0.697.08.6
40 mm0.517.49.0
50 mm0.407.79.4
60 mm0.348.19.8
80 mm0.25—10.2
100 mm0.20—10.6

Panel Resistance According to Span Distance

The technical data sheet includes uniformly distributed load tables for spans from 1.50 to 5.00 m, differentiating external suction and external pressure, single or multiple support, and 0.4/0.4 and 0.5/0.5 mm sheet configurations.

These tables are a technical reference and do not replace project calculations. The spacing between supports must be verified according to wind pressure and suction, building height, location, modulation, and actual facade conditions.

◄ External suction► External pressureValues in kN/m²“—” no published value for that span

Sheet 0.4/0.4 · single span

Swipe the table

ThicknessLoadPermissible load (kN/m²) by distance between supports L (m)
1.50 m1.75 m2.00 m2.25 m2.50 m2.75 m3.00 m3.25 m3.50 m3.75 m4.00 m4.25 m4.50 m4.75 m5.00 m
30 mm◄1.310.790.41————————————
►1.310.790.41————————————
40 mm◄2.341.671.220.860.540.33—————————
►2.341.671.220.860.540.33—————————
50 mm◄3.452.561.921.461.120.870.610.41———————
►3.452.561.921.461.120.870.610.41———————
60 mm◄4.253.122.391.891.531.261.030.830.630.460.33————
►4.253.122.391.891.531.261.030.830.630.460.33————
80 mm◄5.724.213.222.542.061.701.431.221.050.920.800.710.630.500.39
►5.724.213.222.542.061.701.431.221.050.920.800.710.630.500.39
100 mm◄6.355.294.053.202.592.141.801.531.321.151.010.900.800.720.65
►6.355.294.053.202.592.141.801.531.321.151.010.900.800.720.65

Sheet 0.4/0.4 · multi-span

Swipe the table

ThicknessLoadPermissible load (kN/m²) by distance between supports L (m)
1.50 m1.75 m2.00 m2.25 m2.50 m2.75 m3.00 m3.25 m3.50 m3.75 m4.00 m4.25 m4.50 m4.75 m5.00 m
30 mm◄2.021.491.140.900.730.600.510.430.370.32—————
►2.021.491.140.900.730.600.510.430.370.32—————
40 mm◄2.772.031.561.231.000.820.690.590.510.440.390.340.31——
►2.772.031.561.231.000.820.690.590.510.440.390.340.31——
50 mm◄3.152.581.971.561.261.040.880.750.640.560.490.440.390.350.32
►3.152.581.971.561.261.040.880.750.640.560.490.440.390.350.32
60 mm◄3.362.882.391.891.531.261.060.900.780.680.600.530.470.420.38
►3.362.882.391.891.531.261.060.900.780.680.600.530.470.420.38
80 mm◄3.793.252.842.522.061.701.431.221.050.920.800.710.640.570.52
►3.793.252.842.522.061.701.431.221.050.920.800.710.640.570.52
100 mm◄4.213.613.162.812.532.141.801.531.321.151.010.900.800.720.65
►4.213.613.162.812.532.141.801.531.321.151.010.900.800.720.65

Sheet 0.5/0.5 · single span

Swipe the table

ThicknessLoadPermissible load (kN/m²) by distance between supports L (m)
1.50 m1.75 m2.00 m2.25 m2.50 m2.75 m3.00 m3.25 m3.50 m3.75 m4.00 m4.25 m4.50 m4.75 m5.00 m
30 mm◄1.400.850.44————————————
►1.400.850.44————————————
40 mm◄2.471.791.310.930.600.36—————————
►2.471.791.310.930.600.36—————————
50 mm◄3.622.712.061.581.220.950.670.460.30——————
►3.622.712.061.581.220.950.670.460.30——————
60 mm◄4.493.682.832.231.771.411.130.920.700.520.37————
►4.493.682.832.231.771.411.130.920.700.520.37————
80 mm◄5.924.983.813.012.442.011.691.441.241.080.950.830.700.560.44
►5.924.983.813.012.442.011.691.441.241.080.950.830.700.560.44
100 mm◄6.345.444.763.793.072.542.131.821.571.361.201.060.950.850.77
►6.345.444.763.793.072.542.131.821.571.361.201.060.950.850.77

Sheet 0.5/0.5 · multi-span

Swipe the table

ThicknessLoadPermissible load (kN/m²) by distance between supports L (m)
1.50 m1.75 m2.00 m2.25 m2.50 m2.75 m3.00 m3.25 m3.50 m3.75 m4.00 m4.25 m4.50 m4.75 m5.00 m
30 mm◄2.081.631.311.060.860.710.600.500.430.360.31————
►2.081.631.311.060.860.710.600.500.430.360.31————
40 mm◄2.932.401.841.451.180.970.820.700.600.520.460.410.360.33—
►2.932.401.841.451.180.970.820.700.600.520.460.410.360.33—
50 mm◄3.142.702.331.841.491.231.040.880.760.660.580.520.460.410.37
►3.142.702.331.841.491.231.040.880.760.660.580.520.460.410.37
60 mm◄3.362.882.522.231.811.491.261.070.920.800.710.630.560.500.45
►3.362.882.522.231.811.491.261.070.920.800.710.630.560.500.45
80 mm◄3.783.242.842.522.272.011.691.441.241.080.950.840.750.680.61
►3.783.242.842.522.272.011.691.441.241.080.950.840.750.680.61
100 mm◄4.213.613.162.812.532.302.111.821.571.361.201.060.950.850.77
►4.213.613.162.812.532.302.111.821.571.361.201.060.950.850.77

TECHNICAL DATA SHEET

Download the panel technical data sheet

Download the complete technical data sheet for the facade sandwich panel with exposed fastening to consult finishes, dimensions, thicknesses, visible fixing, thermal performance, weights, colors, and load tables.

The document should be used as a technical reference along with the specific conditions of each project.

TECHNICAL IMAGES

Details of the facade panel with visible fixing

QUESTIONS

Frequently Asked Questions about facade sandwich panel with visible fixing

It is an insulating panel for walls and facades whose fastening remains visible on the panel face. It consists of two metal sheets and an insulating PUR or PIR core.

The technical data sheet includes micro-profiled, ribbed, and smooth finishes, allowing the exterior appearance to be adapted to different types of facades and modular construction.

Thicknesses of 30, 40, 50, 60, 80, and 100 mm are available, with an indicated tolerance of ±2 mm.

The declared thermal transmittance ranges from 0.69 W/m²·K for 30 mm to 0.20 W/m²·K for 100 mm. The declared thermal conductivity of the PUR and PIR core is 0.0207 W/m·K.

The technical documentation includes useful widths of 1,000 and 1,100 mm, both with a tolerance of ±2 mm.

It is suitable for walls, prefabricated structures, modular construction, and facades with visible fixing.

LATEST ARTICLES

Guides and Tips on Sandwich Panel

Consult content on panel selection, insulation, assembly, maintenance, rehabilitation, and real applications.

ON-SITE SERVICE

Specialist team for sandwich panel installation

We quote for new builds, refurbishment, roof and facade replacement, flashing installation, and work with sheet metal or skylights.

The quote depends on geometry, height, access, auxiliary equipment, location, fixings and junctions the job must resolve.

Sandwich panel installation on site