The cold storage sandwich panel for freezing is an insulating panel for industrial cold rooms, consisting of two profiled metal sheets and a rigid polyurethane (PUR) or polyisocyanurate (PIR) core.
It is designed for cold storage room enclosures requiring high insulation thicknesses. The technical datasheet covers thicknesses from 60 to 200 mm and widths of 1,000 or 1,165 mm.
The panel is manufactured in accordance with EN 14509 and the documentation indicates assessment and verification of constancy of performance according to system 1.
The indicated manufacturing length is from 4.00 to 14.00 m, with 8.00 m as the maximum recommended length.
Insulating panel intended for industrial cold rooms and refrigerated enclosures. The choice of thickness must be made according to the working temperature, environmental conditions, and required thermal performance.
| Thicknesses | 60, 80 and 100 mm ±2 mm |
|---|---|
| Higher thicknesses | 120, 150, 180 and 200 mm ±2% |
| Effective widths | 1,000 or 1,165 mm ±2 mm |
| Manufacturing length | 4.00 – 14.00 m ±10 mm |
| Maximum recommended length | 8.00 m |
The documentation covers ribbed/ribbed, smooth/ribbed and smooth/smooth configurations.
The indicated standard finish is 25 µm polyester paint. Special 55 µm coatings and a PVC finish suitable for food applications are also covered.
Available colour: RAL 9010, on both the outer and the inner face. Other RAL colours on request.
Colors shown on screen are for guidance only. When the tone is critical, a real sample should be checked before confirming the order.
The installation of the cold storage sandwich panel for freezing must be carried out on a correctly dimensioned structure, ensuring insulation continuity, joint watertightness, and adequate fixing to the support.
Important: permissible spans must be verified with the load tables and the actual conditions of each project.
DECLARED PERFORMANCE
| Configuration | High-thickness insulated panel for industrial cold rooms |
|---|---|
| Manufacturing standard | EN 14509 · performance assessed under system 1 |
| Thicknesses | 100 mm (±2 mm) and 120, 150, 180 and 200 mm (±2%) · 60 and 80 mm on request |
| Useful width | 1,000 or 1,165 mm (±2 mm) |
| Length | 4.00 to 14.00 m, made to measure (±10 mm) · recommended up to 8.00 m |
| Joint | Tongue and groove · different profile for 60 to 100 mm and for 120 to 200 mm |
| Faces | Ribbed/ribbed, smooth/ribbed or smooth/smooth · 1.5 mm rib |
| Steel sheet | S250GD (EN 10346), pre-painted (EN 10169+A1) |
| Sheet thicknesses | 0.5 mm on both faces |
| Core | PUR or PIR · 40 kg/m³ |
| Thermal conductivity | λ = 0.0207 W/m·K |
| Reaction to fire | PIR: B-s2,d0 · high-performance PIR: B-s1,d0 · PUR: not certified |
| Coating | 25 µm polyester · special: 55 µm (RC5) and PVC suitable for food use |
| Colours | RAL 9010 on both faces · other RAL colours on request |
| Thickness | 60 mm | 80 mm | 100 mm | 120 mm | 150 mm | 180 mm | 200 mm |
|---|---|---|---|---|---|---|---|
| U-value Transmittance (W/m²·K) | 0,34 | 0,25 | 0,20 | 0,17 | 0,13 | 0,11 | 0,10 |
| Weight 0.5/0.5 (kg/m²) | 9,9 | 10,7 | 11,5 | 12,3 | 13,5 | 14,7 | 15,5 |
Loads from the technical data sheet for 0.5/0.5 steel sheet, in kN/m², according to the span between supports (in metres).
In walls, external suction and external pressure are differentiated. The values must be used together with the applicable calculation and project conditions.
| Thickness | Load | 1.50 m | 1.75 m | 2.00 m | 2.25 m | 2.50 m | 2.75 m | 3.00 m | 3.25 m | 3.50 m | 3.75 m | 4.00 m | 4.25 m | 4.50 m | 4.75 m | 5.00 m |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 60 mm | Suction | 3,09 | 2,43 | 1,94 | 1,56 | 1,27 | 1,04 | 0,85 | 0,70 | 0,55 | 0,41 | 0,30 | — | — | — | — |
| 60 mm | Pressure | 3,09 | 2,43 | 1,94 | 1,56 | 1,27 | 1,04 | 0,85 | 0,70 | 0,55 | 0,41 | 0,30 | — | — | — | — |
| 80 mm | Suction | 4,59 | 3,69 | 3,01 | 2,48 | 2,07 | 1,73 | 1,46 | 1,24 | 1,05 | 0,90 | 0,77 | 0,66 | 0,57 | 0,46 | 0,37 |
| 80 mm | Pressure | 4,59 | 3,69 | 3,01 | 2,48 | 2,07 | 1,73 | 1,46 | 1,24 | 1,05 | 0,90 | 0,77 | 0,66 | 0,57 | 0,46 | 0,37 |
| 100 mm | Suction | 6,11 | 4,97 | 4,11 | 3,45 | 2,91 | 2,48 | 2,12 | 1,82 | 1,58 | 1,37 | 1,19 | 1,04 | 0,91 | 0,79 | 0,70 |
| 100 mm | Pressure | 6,11 | 4,97 | 4,11 | 3,45 | 2,91 | 2,48 | 2,12 | 1,82 | 1,58 | 1,37 | 1,19 | 1,04 | 0,91 | 0,79 | 0,70 |
| 120 mm | Suction | 7,62 | 6,28 | 5,24 | 4,43 | 3,78 | 3,25 | 2,81 | 2,44 | 2,13 | 1,87 | 1,64 | 1,45 | 1,28 | 1,13 | 1,01 |
| 120 mm | Pressure | 7,62 | 6,28 | 5,24 | 4,43 | 3,78 | 3,25 | 2,81 | 2,44 | 2,13 | 1,87 | 1,64 | 1,45 | 1,28 | 1,13 | 1,01 |
| 150 mm | Suction | 8,26 | 7,08 | 6,20 | 5,51 | 4,96 | 4,44 | 3,85 | 3,28 | 2,83 | 2,47 | 2,17 | 1,92 | 1,71 | 1,54 | 1,39 |
| 150 mm | Pressure | 8,26 | 7,08 | 6,20 | 5,51 | 4,96 | 4,44 | 3,85 | 3,28 | 2,83 | 2,47 | 2,17 | 1,92 | 1,71 | 1,54 | 1,39 |
| 180 mm | Suction | 8,90 | 7,63 | 6,68 | 5,94 | 5,34 | 4,86 | 4,45 | 3,95 | 3,41 | 2,97 | 2,61 | 2,31 | 2,06 | 1,85 | 1,67 |
| 180 mm | Pressure | 8,90 | 7,63 | 6,68 | 5,94 | 5,34 | 4,86 | 4,45 | 3,95 | 3,41 | 2,97 | 2,61 | 2,31 | 2,06 | 1,85 | 1,67 |
| 200 mm | Suction | 9,33 | 8,00 | 7,00 | 6,22 | 5,60 | 5,09 | 4,67 | 4,31 | 3,79 | 3,30 | 2,90 | 2,57 | 2,29 | 2,06 | 1,86 |
| 200 mm | Pressure | 9,33 | 8,00 | 7,00 | 6,22 | 5,60 | 5,09 | 4,67 | 4,31 | 3,79 | 3,30 | 2,90 | 2,57 | 2,29 | 2,06 | 1,86 |
| Thickness | Load | 1.50 m | 1.75 m | 2.00 m | 2.25 m | 2.50 m | 2.75 m | 3.00 m | 3.25 m | 3.50 m | 3.75 m | 4.00 m | 4.25 m | 4.50 m | 4.75 m | 5.00 m |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 60 mm | Suction | 3,36 | 2,75 | 2,30 | 1,96 | 1,68 | 1,46 | 1,28 | 1,13 | 1,00 | 0,90 | 0,80 | 0,72 | 0,65 | 0,58 | 0,53 |
| 60 mm | Pressure | 3,36 | 2,75 | 2,30 | 1,96 | 1,68 | 1,46 | 1,28 | 1,13 | 1,00 | 0,90 | 0,80 | 0,72 | 0,65 | 0,58 | 0,53 |
| 80 mm | Suction | 4,21 | 3,61 | 3,16 | 2,81 | 2,49 | 2,18 | 1,93 | 1,71 | 1,49 | 1,29 | 1,14 | 1,01 | 0,90 | 0,81 | 0,73 |
| 80 mm | Pressure | 4,21 | 3,61 | 3,16 | 2,81 | 2,49 | 2,18 | 1,93 | 1,71 | 1,49 | 1,29 | 1,14 | 1,01 | 0,90 | 0,81 | 0,73 |
| 100 mm | Suction | 4,64 | 3,98 | 3,48 | 3,09 | 2,78 | 2,53 | 2,32 | 2,14 | 1,87 | 1,63 | 1,43 | 1,27 | 1,13 | 1,02 | 0,92 |
| 100 mm | Pressure | 4,64 | 3,98 | 3,48 | 3,09 | 2,78 | 2,53 | 2,32 | 2,14 | 1,87 | 1,63 | 1,43 | 1,27 | 1,13 | 1,02 | 0,92 |
| 120 mm | Suction | 5,06 | 4,34 | 3,80 | 3,38 | 3,04 | 2,76 | 2,53 | 2,34 | 2,17 | 1,96 | 1,73 | 1,53 | 1,36 | 1,22 | 1,10 |
| 120 mm | Pressure | 5,06 | 4,34 | 3,80 | 3,38 | 3,04 | 2,76 | 2,53 | 2,34 | 2,17 | 1,96 | 1,73 | 1,53 | 1,36 | 1,22 | 1,10 |
| 150 mm | Suction | 5,70 | 4,89 | 4,28 | 3,80 | 3,42 | 3,11 | 2,85 | 2,63 | 2,44 | 2,28 | 2,14 | 1,92 | 1,71 | 1,54 | 1,39 |
| 150 mm | Pressure | 5,70 | 4,89 | 4,28 | 3,80 | 3,42 | 3,11 | 2,85 | 2,63 | 2,44 | 2,28 | 2,14 | 1,92 | 1,71 | 1,54 | 1,39 |
| 180 mm | Suction | 6,34 | 5,44 | 4,76 | 4,23 | 3,81 | 3,46 | 3,17 | 2,93 | 2,72 | 2,54 | 2,38 | 2,24 | 2,06 | 1,85 | 1,67 |
| 180 mm | Pressure | 6,34 | 5,44 | 4,76 | 4,23 | 3,81 | 3,46 | 3,17 | 2,93 | 2,72 | 2,54 | 2,38 | 2,24 | 2,06 | 1,85 | 1,67 |
| 200 mm | Suction | 6,77 | 5,80 | 5,08 | 4,51 | 4,06 | 3,69 | 3,39 | 3,13 | 2,90 | 2,71 | 2,54 | 2,39 | 2,26 | 2,06 | 1,86 |
| 200 mm | Pressure | 6,77 | 5,80 | 5,08 | 4,51 | 4,06 | 3,69 | 3,39 | 3,13 | 2,90 | 2,71 | 2,54 | 2,39 | 2,26 | 2,06 | 1,86 |
| Thickness | 1.50 m | 1.75 m | 2.00 m | 2.25 m | 2.50 m | 2.75 m | 3.00 m | 3.25 m | 3.50 m | 3.75 m | 4.00 m | 4.25 m | 4.50 m | 4.75 m | 5.00 m |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 60 mm | 3,29 | 2,61 | 2,11 | 1,71 | 1,41 | 1,16 | 0,96 | 0,80 | 0,67 | 0,56 | 0,47 | 0,39 | 0,33 | 0,27 | 0,22 |
| 80 mm | 4,79 | 3,88 | 3,19 | 2,65 | 2,22 | 1,88 | 1,59 | 1,36 | 1,16 | 1,00 | 0,86 | 0,74 | 0,63 | 0,55 | 0,47 |
| 100 mm | 6,13 | 4,99 | 4,13 | 3,46 | 2,92 | 2,48 | 2,12 | 1,82 | 1,57 | 1,35 | 1,17 | 1,01 | 0,88 | 0,77 | 0,67 |
| 120 mm | 7,53 | 6,29 | 5,25 | 4,44 | 3,79 | 3,25 | 2,81 | 2,44 | 2,12 | 1,86 | 1,63 | 1,43 | 1,25 | 1,11 | 0,98 |
| 150 mm | 8,16 | 6,98 | 6,10 | 5,41 | 4,68 | 4,02 | 3,47 | 3,01 | 2,62 | 2,28 | 2,00 | 1,75 | 1,54 | 1,35 | 1,19 |
| 180 mm | 8,79 | 7,52 | 6,57 | 5,83 | 5,23 | 4,75 | 4,34 | 3,84 | 3,30 | 2,86 | 2,50 | 2,20 | 1,95 | 1,74 | 1,56 |
| 200 mm | 9,18 | 7,85 | 6,85 | 6,07 | 5,45 | 4,94 | 4,52 | 4,16 | 3,64 | 3,15 | 2,75 | 2,42 | 2,14 | 1,91 | 1,71 |
| Thickness | 5.25 m | 5.50 m | 5.75 m | 6.00 m | 6.25 m | 6.50 m | 6.75 m | 7.00 m | 7.25 m | 7.50 m | 7.75 m | 8.00 m | 8.25 m | 8.50 m | 8.75 m | 9.00 m |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 60 mm | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 80 mm | 0,41 | 0,35 | 0,30 | 0,26 | 0,22 | — | — | — | — | — | — | — | — | — | — | — |
| 100 mm | 0,58 | 0,50 | 0,44 | 0,38 | 0,33 | 0,29 | 0,25 | 0,20 | — | — | — | — | — | — | — | — |
| 120 mm | 0,86 | 0,76 | 0,67 | 0,60 | 0,53 | 0,47 | 0,41 | 0,36 | 0,32 | 0,28 | 0,25 | 0,22 | — | — | — | — |
| 150 mm | 1,04 | 0,92 | 0,78 | 0,64 | 0,52 | 0,42 | 0,33 | 0,25 | — | — | — | — | — | — | — | — |
| 180 mm | 1,40 | 1,27 | 1,15 | 1,05 | 0,96 | 0,86 | 0,77 | 0,65 | 0,55 | 0,46 | 0,38 | 0,31 | 0,24 | — | — | — |
| 200 mm | 1,53 | 1,38 | 1,25 | 1,14 | 1,04 | 0,95 | 0,87 | 0,80 | 0,73 | 0,67 | 0,58 | 0,49 | 0,41 | 0,34 | 0,28 | 0,22 |
TECHNICAL DATASHEET
Consult the technical datasheet with dimensions, materials, thermal behavior, weights, finishes and product load tables.
QUESTIONS
The technical datasheet destines it for industrial cold rooms and refrigerated enclosures.
The documentation covers 60, 80, 100, 120, 150, 180 and 200 mm.
The indicated widths are 1,000 and 1,165 mm, with a tolerance of ±2 mm.
The declared transmittance ranges from 0.34 W/m²·K for 60 mm to 0.10 W/m²·K for 200 mm.
The datasheet covers a special PVC coating suitable for food applications.
ACCESSORIES FOR COLD STORAGE PANEL
LATEST ARTICLES
Consult content on panel selection, insulation, assembly, maintenance, rehabilitation and real applications.
YOU MAY ALSO BE INTERESTED IN
ON-SITE SERVICE
We quote for new builds, refurbishment, roof and facade replacement, flashing installation, and work with sheet metal or skylights.
The quote depends on geometry, height, access, auxiliary equipment, location, fixings and junctions the job must resolve.