Cold Storage Sandwich Panel – Cold Rooms

Configura tu panel

Selecciona las opciones disponibles. Te prepararemos el precio según medidas, cantidad, transporte y montaje.

Fabricación a medida

Asesoramiento técnico

Transporte a obra

Montaje especializado

PRODUCT DESCRIPTION

Cold storage sandwich panel for freezing

Description

The cold storage sandwich panel for freezing is an insulating panel for industrial cold rooms, consisting of two profiled metal sheets and a rigid polyurethane (PUR) or polyisocyanurate (PIR) core.

It is designed for cold storage room enclosures requiring high insulation thicknesses. The technical datasheet covers thicknesses from 60 to 200 mm and widths of 1,000 or 1,165 mm.

The panel is manufactured in accordance with EN 14509 and the documentation indicates assessment and verification of constancy of performance according to system 1.

The indicated manufacturing length is from 4.00 to 14.00 m, with 8.00 m as the maximum recommended length.

Characteristics

Application

Insulating panel intended for industrial cold rooms and refrigerated enclosures. The choice of thickness must be made according to the working temperature, environmental conditions, and required thermal performance.

Dimensions

Thicknesses60, 80 and 100 mm ±2 mm
Higher thicknesses120, 150, 180 and 200 mm ±2%
Effective widths1,000 or 1,165 mm ±2 mm
Manufacturing length4.00 – 14.00 m ±10 mm
Maximum recommended length8.00 m

Metal support

  • Steel sheet quality S250GD according to EN 10346.
  • Pre-painted coils with organic coating according to EN 10169+A1.
  • Indicated sheet thickness: 0.5 mm.

Insulating core

  • Polyurethane (PUR) or polyisocyanurate (PIR).
  • Declared thermal conductivity: 0.0207 W/m·K.
  • Density: 40 kg/m³.
  • PUR reaction to fire: B-s2,d0.
  • PIR reaction to fire: B-s2,d0.
  • High-performance PIR: B-s1,d0.

Surface finishes

The documentation covers ribbed/ribbed, smooth/ribbed and smooth/smooth configurations.

Coatings and colors

The indicated standard finish is 25 µm polyester paint. Special 55 µm coatings and a PVC finish suitable for food applications are also covered.

The represented color range includes RAL 9010, RAL 9006, RAL 9004, RAL 7022, RAL 7016, RAL 7012, RAL 6005, RAL 5010, RAL 3009 and RAL 1015.

Colors shown on screen are for guidance only. When the tone is critical, a real sample should be checked before confirming the order.

Installation

The installation of the cold storage sandwich panel for freezing must be carried out on a correctly dimensioned structure, ensuring insulation continuity, joint watertightness, and adequate fixing to the support.

  • Check the modulation and the spacing between supports according to the project loads.
  • Select the thickness based on the internal temperature and the required insulation level.
  • Execute the joints avoiding thermal bridges and loss of watertightness.
  • Use fixings suitable for the support, the panel thickness, and the planned loads.
  • Correctly resolve corners, junctions, plinths, ceilings, and installation passages.
  • Avoid damage to the coating during handling and assembly.

Important: permissible spans must be verified with the load tables and the actual conditions of each project.

DECLARED PERFORMANCE

Insulation, weight and technical data

Technical data

Main characteristics

ApplicationIndustrial cold rooms
Effective width1,000 / 1,165 mm ±2 mm
Total thickness60 / 80 / 100 / 120 / 150 / 180 / 200 mm
Steel sheetS250GD · EN 10346
Sheet thickness0.5 mm
CorePUR or PIR
Core density40 kg/m³
Thermal conductivity0.0207 W/m·K
Manufacturing standardEN 14509

Thermal behavior and weight

Thickness60 mm80 mm100 mm120 mm150 mm180 mm200 mm
U-value Transmittance (W/m²·K)0,340,250,200,170,130,110,10
Weight 0.5/0.5 (kg/m²)9,910,711,512,313,514,715,5

Cold storage panel load tables

The following tables reproduce as actual HTML tables the values from the technical datasheet for 0.5/0.5 steel sheet. Loads are expressed in kN/m² and spans in meters.

In walls, external suction and external pressure are differentiated. The values must be used together with the applicable calculation and project conditions.

Wall application – single support condition

ThicknessLoad1.50 m1.75 m2.00 m2.25 m2.50 m2.75 m3.00 m3.25 m3.50 m3.75 m4.00 m4.25 m4.50 m4.75 m5.00 m
60 mmSuction3,092,431,941,561,271,040,850,700,550,410,30————
60 mmPressure3,092,431,941,561,271,040,850,700,550,410,30————
80 mmSuction4,593,693,012,482,071,731,461,241,050,900,770,660,570,460,37
80 mmPressure4,593,693,012,482,071,731,461,241,050,900,770,660,570,460,37
100 mmSuction6,114,974,113,452,912,482,121,821,581,371,191,040,910,790,70
100 mmPressure6,114,974,113,452,912,482,121,821,581,371,191,040,910,790,70
120 mmSuction7,626,285,244,433,783,252,812,442,131,871,641,451,281,131,01
120 mmPressure7,626,285,244,433,783,252,812,442,131,871,641,451,281,131,01
150 mmSuction8,267,086,205,514,964,443,853,282,832,472,171,921,711,541,39
150 mmPressure8,267,086,205,514,964,443,853,282,832,472,171,921,711,541,39
180 mmSuction8,907,636,685,945,344,864,453,953,412,972,612,312,061,851,67
180 mmPressure8,907,636,685,945,344,864,453,953,412,972,612,312,061,851,67
200 mmSuction9,338,007,006,225,605,094,674,313,793,302,902,572,292,061,86
200 mmPressure9,338,007,006,225,605,094,674,313,793,302,902,572,292,061,86

Wall application – multiple support condition

ThicknessLoad1.50 m1.75 m2.00 m2.25 m2.50 m2.75 m3.00 m3.25 m3.50 m3.75 m4.00 m4.25 m4.50 m4.75 m5.00 m
60 mmSuction3,362,752,301,961,681,461,281,131,000,900,800,720,650,580,53
60 mmPressure3,362,752,301,961,681,461,281,131,000,900,800,720,650,580,53
80 mmSuction4,213,613,162,812,492,181,931,711,491,291,141,010,900,810,73
80 mmPressure4,213,613,162,812,492,181,931,711,491,291,141,010,900,810,73
100 mmSuction4,643,983,483,092,782,532,322,141,871,631,431,271,131,020,92
100 mmPressure4,643,983,483,092,782,532,322,141,871,631,431,271,131,020,92
120 mmSuction5,064,343,803,383,042,762,532,342,171,961,731,531,361,221,10
120 mmPressure5,064,343,803,383,042,762,532,342,171,961,731,531,361,221,10
150 mmSuction5,704,894,283,803,423,112,852,632,442,282,141,921,711,541,39
150 mmPressure5,704,894,283,803,423,112,852,632,442,282,141,921,711,541,39
180 mmSuction6,345,444,764,233,813,463,172,932,722,542,382,242,061,851,67
180 mmPressure6,345,444,764,233,813,463,172,932,722,542,382,242,061,851,67
200 mmSuction6,775,805,084,514,063,693,393,132,902,712,542,392,262,061,86
200 mmPressure6,775,805,084,514,063,693,393,132,902,712,542,392,262,061,86

Roof application – single support condition (span 1.50 to 5.00 m)

Thickness1.50 m1.75 m2.00 m2.25 m2.50 m2.75 m3.00 m3.25 m3.50 m3.75 m4.00 m4.25 m4.50 m4.75 m5.00 m
60 mm3,292,612,111,711,411,160,960,800,670,560,470,390,330,270,22
80 mm4,793,883,192,652,221,881,591,361,161,000,860,740,630,550,47
100 mm6,134,994,133,462,922,482,121,821,571,351,171,010,880,770,67
120 mm7,536,295,254,443,793,252,812,442,121,861,631,431,251,110,98
150 mm8,166,986,105,414,684,023,473,012,622,282,001,751,541,351,19
180 mm8,797,526,575,835,234,754,343,843,302,862,502,201,951,741,56
200 mm9,187,856,856,075,454,944,524,163,643,152,752,422,141,911,71

Roof application – continued (span 5.25 to 9.00 m)

Thickness5.25 m5.50 m5.75 m6.00 m6.25 m6.50 m6.75 m7.00 m7.25 m7.50 m7.75 m8.00 m8.25 m8.50 m8.75 m9.00 m
60 mm————————————————
80 mm0,410,350,300,260,22———————————
100 mm0,580,500,440,380,330,290,250,20————————
120 mm0,860,760,670,600,530,470,410,360,320,280,250,22————
150 mm1,040,920,780,640,520,420,330,25————————
180 mm1,401,271,151,050,960,860,770,650,550,460,380,310,24———
200 mm1,531,381,251,141,040,950,870,800,730,670,580,490,410,340,280,22

TECHNICAL DATASHEET

Technical datasheet for freezing cold storage sandwich panel

Consult the technical datasheet with dimensions, materials, thermal behavior, weights, finishes and product load tables.

The button link can be replaced by the final PDF URL once uploaded to the WordPress library.

TECHNICAL IMAGES

Details of the cold storage sandwich panel

QUESTIONS

Frequently asked questions about cold storage sandwich panel

The technical datasheet destines it for industrial cold rooms and refrigerated enclosures.

The documentation covers 60, 80, 100, 120, 150, 180 and 200 mm.

The indicated widths are 1,000 and 1,165 mm, with a tolerance of ±2 mm.

The declared transmittance ranges from 0.34 W/m²·K for 60 mm to 0.10 W/m²·K for 200 mm.

The datasheet covers a special PVC coating suitable for food applications.

Yes. The values from the technical datasheet have been transferred to actual HTML tables for walls and roofs, avoiding the use of screenshots.

ACCESSORIES FOR COLD STORAGE PANEL

Accessories and flashings for cold storage sandwich panel

You may also like…

LATEST ARTICLES

Guides and tips on sandwich panel

Consult content on panel selection, insulation, assembly, maintenance, rehabilitation and real applications.

TAMBIÉN TE PUEDE INTERESAR

Productos relacionados

SERVICIO DE OBRA

Equipo especializado para el montaje de panel sandwich

Valoramos obra nueva, rehabilitación, sustitución de cubiertas y fachadas, colocación de rematería y trabajos con chapa o lucernarios.

El presupuesto depende de la geometría, altura, accesos, medios auxiliares, ubicación, fijaciones y encuentros que deba resolver la obra.

PRESUPUESTO PERSONALIZADO

Solicita precio de panel sandwich

Indica tipo de panel, superficie, espesor, localidad y si necesitas suministro o montaje. Revisaremos los datos para preparar una propuesta ajustada.

SOLICITUD RÁPIDA

Cuéntanos qué necesitas

Completa los datos principales y prepararemos una propuesta ajustada a tu proyecto.

Datos de contacto¿Con quién debemos hablar?
Datos del proyectoTipo de panel, servicio y cantidades.
Detalles y documentaciónAñade la información necesaria para valorar correctamente.