973 228 164 · 699 147 762

Support Phone Number

Made to measure

Technical advice

Delivery to site

Specialist installation

SANDWICH PANEL · CONFIGURATION AND QUOTE

Single Facade Sheet – Stepped Profile

Configure your panel

Select the available options. We will prepare the price based on dimensions, quantity, transport and installation.

PERSONALISED QUOTE

Request a price for this product

Tell us the panel type, area, thickness, location and whether you need supply only or installation. We’ll review the details to prepare a tailored proposal.

QUICK REQUEST

Tell us what you need

Complete the main details and we will prepare a proposal tailored to your project.

Description: Single Facade Sheet – Stepped Profile

The use of profiled sheet for roof and facade cladding is a technically and economically competitive solution.
By varying the thickness of the plate and the geometrical characteristics of the section, we can obtain lightweight components capable of overcoming different spans.

The different profiles are obtained by roll-forming coils of pre-painted or galvanized cold-rolled sheet metal.
The profiled sheet can be corrugated or trapezoidal, with variable profile heights, spacing, dimensions and may or may not have rigid ribs.

In order to provide better thermal and acoustic insulation, a layer of insulation is used between the two cladding sheets.
The secondary structure is fastened with galvanized screws, stainless steel self-tapping screws or self-drilling screws.

In the same type of sheet metal, we also manufacture all the necessary accessories for a correct waterproofing, in particular: ruffles, ends, ridges, drips, etc.

Section and characteristics

Profile 30 trapezoidal sheet: cross-section and dimensions (effective width 1,088 mm, overall width 1,120 mm, rib height 30 mm, pitch 272 mm)
Profile 30 cross-section: effective width 1,088 mm, overall width 1,120 mm, rib height 30 mm and rib pitch 272 mm.
Detail of both faces of the profile 30 trapezoidal sheet
Detail of faces 1 and 2 of the sheet.

Load table

Mechanical properties by thickness

Swipe the table

Nominal thickness (mm)Design thickness (mm)Weight** (kg/m²)Top flange in compressionBottom flange in compressionWeb crippling resistance (kN/m)Shear resistance (kN/m)
Moment resistance* (kN·m/m)Moment of inertia* (cm⁴/m)Moment resistance* (kN·m/m)Moment of inertia* (cm⁴/m)
0.500.464.510.564.880.583.187.2116.27
0.600.565.410.816.750.784.1010.3424.11
0.700.666.311.088.370.995.0813.9433.02
0.750.716.761.199.211.075.5915.9135.52

* Moment resistance and moment of inertia calculated without considering shear lag effects. ** Weight including overlap. Bending radius: 4 mm. SLS – deflection limit: L/150 for upward loads and L/200 for downward loads.

Direct design tables

Allowable load values (unfactored) in kN/m², by number of supports and distance between supports (span L).

▲ Upward load▼ Downward loadValues in kN/m²Loads governed by SLS (deflection)No colour: governed by ULS“—” no published value

2 supports

Swipe the table

ThicknessLoadAllowable load (kN/m²) by distance between supports L (m)
1.00 m1.10 m1.20 m1.30 m1.40 m1.50 m1.60 m1.70 m1.80 m1.90 m2.00 m2.10 m2.20 m2.30 m2.40 m2.50 m
0.50 mm▲2.832.341.981.581.271.030.850.710.600.510.440.380.330.290.250.22
▼2.732.251.881.601.371.170.960.790.660.550.470.400.340.290.250.22
0.60 mm▲3.793.142.602.041.641.331.100.910.770.650.560.490.420.370.330.29
▼3.953.252.732.321.961.581.301.070.900.750.640.550.470.400.350.30
0.70 mm▲4.683.883.222.532.031.651.361.130.950.810.700.600.520.460.400.36
▼5.094.203.522.992.431.971.611.331.110.940.800.680.580.500.430.38
0.75 mm▲5.094.213.542.782.231.811.501.251.050.890.770.660.580.500.440.39
▼5.614.633.883.302.682.171.781.471.231.040.880.750.640.560.480.42

3 supports

Swipe the table

ThicknessLoadAllowable load (kN/m²) by distance between supports L (m)
1.00 m1.10 m1.20 m1.30 m1.40 m1.50 m1.60 m1.70 m1.80 m1.90 m2.00 m2.10 m2.20 m2.30 m2.40 m2.50 m
0.50 mm▲2.802.321.951.671.441.261.110.990.880.800.720.660.600.550.510.47
▼1.771.521.321.161.030.920.820.750.670.610.560.520.480.440.410.38
0.60 mm▲4.043.342.812.402.081.811.601.421.271.141.030.940.860.790.730.67
▼2.412.061.801.581.411.251.121.010.910.830.770.700.650.600.550.51
0.70 mm▲5.184.293.623.092.672.332.061.831.631.471.331.211.111.020.940.87
▼3.102.662.322.041.821.611.441.311.191.080.990.910.840.770.720.67
0.75 mm▲5.714.733.983.402.942.572.262.011.801.621.471.331.221.121.030.95
▼3.482.992.602.302.021.811.621.461.341.221.101.020.930.860.790.73

4 supports

Swipe the table

ThicknessLoadAllowable load (kN/m²) by distance between supports L (m)
1.00 m1.10 m1.20 m1.30 m1.40 m1.50 m1.60 m1.70 m1.80 m1.90 m2.00 m2.10 m2.20 m2.30 m2.40 m2.50 m
0.50 mm▲3.492.892.432.081.791.571.381.231.100.980.830.720.630.550.480.43
▼2.131.831.611.421.261.121.010.910.830.760.690.640.590.540.500.46
0.60 mm▲5.004.173.512.992.582.261.991.751.481.261.080.930.810.710.620.55
▼2.902.492.171.911.701.531.371.251.131.030.940.860.800.740.680.63
0.70 mm▲6.265.274.503.853.332.912.562.171.831.551.331.151.000.880.770.68
▼3.743.222.812.482.211.981.771.601.471.341.221.121.040.960.890.78
0.75 mm▲6.935.844.974.243.673.202.822.392.011.711.471.271.100.970.850.75
▼4.193.613.152.782.482.202.001.801.631.491.381.261.151.060.990.86

Available colours

  • RAL 1015
    Light ivory
  • RAL 3000
    Flame red
  • RAL 3009
    Oxide red
  • RAL 5005
    Signal blue
  • RAL 5008
    Grey blue
  • RAL 5010
    Gentian blue
  • RAL 6005
    Moss green
  • RAL 6009
    Fir green
  • RAL 6021
    Pale green
  • RAL 7012
    Basalt grey
  • RAL 7016
    Anthracite grey
  • RAL 7022
    Umbra grey
  • RAL 8004
    Terracotta
  • RAL 8017
    Chocolate brown
  • RAL 9005
    Jet black
  • RAL 9006
    White aluminium
  • RAL 9007
    Grey aluminium
  • RAL 9010
    Pure white

On-screen colours are for guidance only. If the exact shade matters, ask for a real sample before confirming your order.

Technical data sheet

Request the technical data sheet

ON-SITE SERVICE

Specialist team for sandwich panel installation

We quote for new builds, refurbishment, roof and facade replacement, flashing installation, and work with sheet metal or skylights.

The quote depends on geometry, height, access, auxiliary equipment, location, fixings and junctions the job must resolve.

Sandwich panel installation on site