The aged ochre tile sandwich panel is an insulating roof panel with geometry inspired by traditional tile. It consists of two profiled metal sheets bonded to a rigid core of polyurethane (PUR) or polyisocyanurate (PIR).
The aged ochre exterior finish provides a textured appearance with an earthy tone and traditional look. The outer sheet has a textured finish to increase visual similarity to a conventional tile roof.
It is suitable for roofs with a minimum slope of 10 %. Its useful width is 1,000 mm and it is manufactured in thicknesses of 30, 40 and 50 mm.
The stated manufacturing length is 2.10 to 14.00 m, in multiples of 0.35 m, with a recommended maximum length of 8.05 m.
Insulating panel intended for roofs with a minimum slope of 10 %. Its geometry reproduces the appearance of traditional tile and integrates cladding and insulation in a single prefabricated element.
| Thicknesses | 30, 40 and 50 mm ±2 mm |
|---|---|
| Useful width | 1,000 mm ±2 mm |
| Longitudinal module | 350 mm |
| Approximate profile spacing | 200 mm |
| Approximate wave height | 50 mm |
| Manufacturing length | 2.10 – 14.00 m, in multiples of 0.35 m |
| Recommended maximum length | 8.05 m |
Tolerances according to EN 14509, in accordance with the technical datasheet.
This product is presented with an aged ochre exterior finish, a textured surface with a traditional appearance and earthy tone.
The technical datasheet specifies as standard exterior finish a 25 µm textured polyester paint. It also includes special 55 µm coatings and 180 µm PVC interior coating with wood appearance, as well as the possibility of metallic coating in lacquered aluminium.
Available colour: aged albero (ochre), with the inner face in RAL 9010 or a planked wood finish. Other RAL colours on request.
The colours shown on screen are indicative. When tone is critical, a real sample should be checked before confirming the order.
Installation of the aged ochre tile sandwich panel must be carried out on a correctly dimensioned structure and with a minimum slope of 10 %.
In more severe environments, the technical datasheet recommends applying silicone to the panel joint to help prevent condensation.
Important: admissible spans must be verified using the load tables and the actual conditions of each roof.
DECLARED PERFORMANCE
| Configuration | Tile-effect insulated roof panel |
|---|---|
| Manufacturing standard | EN 14509 · CE marking |
| Minimum slope | 10% |
| Thicknesses | 30, 40 and 50 mm (±2 mm) |
| Useful width | 1,000 mm (±2 mm) |
| Length | 2.10 to 14.00 m, made to measure in multiples of 0.35 m · recommended up to 8.05 m |
| Wave | 50 mm high · 200 mm pitch · 350 mm longitudinal module |
| Steel sheet | S250GD, galvanised |
| Sheet thicknesses | 0.4 / 0.5 / 0.6 mm |
| Core | PUR or PIR · 40 kg/m³ |
| Thermal conductivity | λ = 0.0207 W/m·K |
| Reaction to fire | High-performance PIR: B-s1,d0 · PUR: not certified |
| Coating | 25 µm textured polyester · 55 µm special coating |
| Inner face | Ribbed or planked profile · optional 180 µm wood-effect PVC or pre-painted aluminium |
| Colours | Aged albero (ochre), textured · inner face RAL 9010 or planked wood finish · other RAL colours on request |
| Thickness | U-value transmittance | Weight 0.5/0.4 | Weight 0.5/0.5 |
|---|---|---|---|
| 30 mm | 0.45 W/m²·K | 10.8 kg/m² | 11.7 kg/m² |
| 40 mm | 0.37 W/m²·K | 11.2 kg/m² | 12.1 kg/m² |
| 50 mm | 0.31 W/m²·K | 11.6 kg/m² | 12.5 kg/m² |
Uniformly distributed loads from the technical data sheet for spans from 1.05 to 3.50 m, for upward (▲) or downward (▼) load, single or multiple support and 0.5/0.4 or 0.5/0.5 mm sheet.
These values are a technical reference and do not replace the structural calculation of the project. Actual loads, support conditions and specific requirements of each roof must be verified.
| Thickness | Load | 1.05 m | 1.40 m | 1.75 m | 2.10 m | 2.45 m | 2.80 m | 3.15 m | 3.50 m |
|---|---|---|---|---|---|---|---|---|---|
| 30 mm | ▲ | 2,52 | 1,55 | 1,08 | 0,81 | 0,64 | 0,52 | 0,44 | 0,37 |
| 30 mm | ▼ | 1,86 | 1,10 | 0,73 | 0,51 | 0,37 | — | — | — |
| 40 mm | ▲ | 2,69 | 1,70 | 1,21 | 0,92 | 0,73 | 0,60 | 0,51 | 0,43 |
| 40 mm | ▼ | 1,98 | 1,20 | 0,81 | 0,59 | 0,44 | 0,33 | — | — |
| 50 mm | ▲ | 2,86 | 1,85 | 1,35 | 1,04 | 0,84 | 0,69 | 0,58 | 0,50 |
| 50 mm | ▼ | 2,11 | 1,32 | 0,91 | 0,67 | 0,50 | 0,39 | 0,30 | — |
| Thickness | Load | 1.05 m | 1.40 m | 1.75 m | 2.10 m | 2.45 m | 2.80 m | 3.15 m | 3.50 m |
|---|---|---|---|---|---|---|---|---|---|
| 30 mm | ▲ | 2,52 | 1,53 | 0,96 | 0,67 | 0,50 | 0,40 | 0,33 | — |
| 30 mm | ▼ | 1,86 | 1,10 | 0,73 | 0,51 | 0,37 | — | — | — |
| 40 mm | ▲ | 2,69 | 1,68 | 1,07 | 0,73 | 0,54 | 0,43 | 0,35 | — |
| 40 mm | ▼ | 1,86 | 1,10 | 0,73 | 0,51 | 0,37 | — | — | — |
| 50 mm | ▲ | 2,86 | 1,85 | 1,20 | 0,82 | 0,63 | 0,50 | 0,40 | — |
| 50 mm | ▼ | 1,86 | 1,10 | 0,73 | 0,51 | 0,37 | — | — | — |
| Thickness | Load | 1.05 m | 1.40 m | 1.75 m | 2.10 m | 2.45 m | 2.80 m | 3.15 m | 3.50 m |
|---|---|---|---|---|---|---|---|---|---|
| 30 mm | ▲ | 2,52 | 1,55 | 1,08 | 0,81 | 0,64 | 0,53 | 0,44 | 0,38 |
| 30 mm | ▼ | 1,86 | 1,10 | 0,73 | 0,51 | 0,38 | — | — | — |
| 40 mm | ▲ | 2,69 | 1,70 | 1,21 | 0,93 | 0,74 | 0,61 | 0,51 | 0,44 |
| 40 mm | ▼ | 1,98 | 1,21 | 0,82 | 0,59 | 0,44 | 0,33 | — | — |
| 50 mm | ▲ | 2,87 | 1,86 | 1,35 | 1,05 | 0,84 | 0,70 | 0,59 | 0,51 |
| 50 mm | ▼ | 2,11 | 1,32 | 0,92 | 0,67 | 0,51 | 0,39 | 0,30 | — |
| Thickness | Load | 1.05 m | 1.40 m | 1.75 m | 2.10 m | 2.45 m | 2.80 m | 3.15 m | 3.50 m |
|---|---|---|---|---|---|---|---|---|---|
| 30 mm | ▲ | 2,52 | 1,54 | 0,97 | 0,68 | 0,50 | 0,40 | 0,33 | — |
| 30 mm | ▼ | 1,86 | 1,10 | 0,73 | 0,51 | 0,38 | — | — | — |
| 40 mm | ▲ | 2,69 | 1,69 | 1,08 | 0,73 | 0,54 | 0,43 | 0,35 | — |
| 40 mm | ▼ | 1,98 | 1,21 | 0,82 | 0,59 | 0,44 | 0,33 | — | — |
| 50 mm | ▲ | 2,87 | 1,86 | 1,21 | 0,82 | 0,63 | 0,50 | 0,40 | 0,30 |
| 50 mm | ▼ | 2,11 | 1,32 | 0,92 | 0,67 | 0,51 | 0,39 | 0,30 | — |
▲ Upward load · ▼ Downward load · Values in kN/m² according to span L indicated.
TECHNICAL DATASHEET
The data in this description are taken from the product’s technical documentation: dimensions, thicknesses, thermal performance, weights, finishes and load tables.
If you require additional documentation for a project, request it stating dimensions, thickness and intended use.
QUESTIONS
It is an insulating roof panel with traditional tile geometry and textured aged ochre exterior finish. It integrates two metal sheets and a PUR or PIR insulating core.
The technical datasheet indicates a minimum slope of 10 %. The project must also resolve overlaps, trims, water drainage and loads according to the actual conditions of the roof.
The technical documentation includes thicknesses of 30, 40 and 50 mm, with a stated tolerance of ±2 mm.
The declared thermal transmittance is 0.45 W/m²·K for 30 mm, 0.37 W/m²·K for 40 mm and 0.31 W/m²·K for 50 mm.
The stated manufacturing length ranges from 2.10 to 14.00 m, in multiples of 0.35 m. The recommended maximum length in the datasheet is 8.05 m.
The tables on this page show uniformly distributed loads in kN/m² according to thickness, span, load direction, support condition and sheet thickness combination. They should be used as a reference and verified for each project.
TRIMS FOR TILE PANEL
LATEST ARTICLES
Browse content on panel selection, insulation, installation, maintenance, refurbishment and real applications.
YOU MAY ALSO BE INTERESTED IN
ON-SITE SERVICE
We quote for new builds, refurbishment, roof and facade replacement, flashing installation, and work with sheet metal or skylights.
The quote depends on geometry, height, access, auxiliary equipment, location, fixings and junctions the job must resolve.