973 228 164 · 699 147 762

Support Phone Number

Made to measure

Technical advice

Delivery to site

Specialist installation

SANDWICH PANEL · CONFIGURATION AND QUOTE

Cold Storage Sandwich Panel – Cold Rooms

Configure your panel

Select the available options. We will prepare the price based on dimensions, quantity, transport and installation.

PERSONALISED QUOTE

Request a price for this product

Tell us the panel type, area, thickness, location and whether you need supply only or installation. We’ll review the details to prepare a tailored proposal.

QUICK REQUEST

Tell us what you need

Complete the main details and we will prepare a proposal tailored to your project.

PRODUCT DESCRIPTION

Cold storage sandwich panel for freezing

Description

The cold storage sandwich panel for freezing is an insulating panel for industrial cold rooms, consisting of two profiled metal sheets and a rigid polyurethane (PUR) or polyisocyanurate (PIR) core.

It is designed for cold storage room enclosures requiring high insulation thicknesses. The technical datasheet covers thicknesses from 60 to 200 mm and widths of 1,000 or 1,165 mm.

The panel is manufactured in accordance with EN 14509 and the documentation indicates assessment and verification of constancy of performance according to system 1.

The indicated manufacturing length is from 4.00 to 14.00 m, with 8.00 m as the maximum recommended length.

Characteristics

Application

Insulating panel intended for industrial cold rooms and refrigerated enclosures. The choice of thickness must be made according to the working temperature, environmental conditions, and required thermal performance.

Dimensions

Thicknesses60, 80 and 100 mm ±2 mm
Higher thicknesses120, 150, 180 and 200 mm ±2%
Effective widths1,000 or 1,165 mm ±2 mm
Manufacturing length4.00 – 14.00 m ±10 mm
Maximum recommended length8.00 m

Metal support

  • Steel sheet quality S250GD according to EN 10346.
  • Pre-painted coils with organic coating according to EN 10169+A1.
  • Indicated sheet thickness: 0.5 mm.

Insulating core

  • Polyurethane (PUR) or polyisocyanurate (PIR).
  • Declared thermal conductivity: 0.0207 W/m·K.
  • Density: 40 kg/m³.
  • PUR reaction to fire: not certified.
  • PIR reaction to fire: B-s2,d0.
  • High-performance PIR: B-s1,d0.

Surface finishes

The documentation covers ribbed/ribbed, smooth/ribbed and smooth/smooth configurations.

Coatings and colors

The indicated standard finish is 25 µm polyester paint. Special 55 µm coatings and a PVC finish suitable for food applications are also covered.

Available colour: RAL 9010, on both the outer and the inner face. Other RAL colours on request.

Colors shown on screen are for guidance only. When the tone is critical, a real sample should be checked before confirming the order.

Installation

The installation of the cold storage sandwich panel for freezing must be carried out on a correctly dimensioned structure, ensuring insulation continuity, joint watertightness, and adequate fixing to the support.

  • Check the modulation and the spacing between supports according to the project loads.
  • Select the thickness based on the internal temperature and the required insulation level.
  • Execute the joints avoiding thermal bridges and loss of watertightness.
  • Use fixings suitable for the support, the panel thickness, and the planned loads.
  • Correctly resolve corners, junctions, plinths, ceilings, and installation passages.
  • Avoid damage to the coating during handling and assembly.

Important: permissible spans must be verified with the load tables and the actual conditions of each project.

DECLARED PERFORMANCE

Insulation, weight and technical data

Technical data

Main characteristics

ConfigurationHigh-thickness insulated panel for industrial cold rooms
Manufacturing standardEN 14509 · performance assessed under system 1
Thicknesses100 mm (±2 mm) and 120, 150, 180 and 200 mm (±2%) · 60 and 80 mm on request
Useful width1,000 or 1,165 mm (±2 mm)
Length4.00 to 14.00 m, made to measure (±10 mm) · recommended up to 8.00 m
JointTongue and groove · different profile for 60 to 100 mm and for 120 to 200 mm
FacesRibbed/ribbed, smooth/ribbed or smooth/smooth · 1.5 mm rib
Steel sheetS250GD (EN 10346), pre-painted (EN 10169+A1)
Sheet thicknesses0.5 mm on both faces
CorePUR or PIR · 40 kg/m³
Thermal conductivityλ = 0.0207 W/m·K
Reaction to firePIR: B-s2,d0 · high-performance PIR: B-s1,d0 · PUR: not certified
Coating25 µm polyester · special: 55 µm (RC5) and PVC suitable for food use
ColoursRAL 9010 on both faces · other RAL colours on request

Thermal behavior and weight

Thickness60 mm80 mm100 mm120 mm150 mm180 mm200 mm
U-value Transmittance (W/m²·K)0,340,250,200,170,130,110,10
Weight 0.5/0.5 (kg/m²)9,910,711,512,313,514,715,5

Cold storage panel load tables

Loads from the technical data sheet for 0.5/0.5 steel sheet, in kN/m², according to the span between supports (in metres).

In walls, external suction and external pressure are differentiated. The values must be used together with the applicable calculation and project conditions.

Wall application – single support condition

ThicknessLoad1.50 m1.75 m2.00 m2.25 m2.50 m2.75 m3.00 m3.25 m3.50 m3.75 m4.00 m4.25 m4.50 m4.75 m5.00 m
60 mmSuction3,092,431,941,561,271,040,850,700,550,410,30————
60 mmPressure3,092,431,941,561,271,040,850,700,550,410,30————
80 mmSuction4,593,693,012,482,071,731,461,241,050,900,770,660,570,460,37
80 mmPressure4,593,693,012,482,071,731,461,241,050,900,770,660,570,460,37
100 mmSuction6,114,974,113,452,912,482,121,821,581,371,191,040,910,790,70
100 mmPressure6,114,974,113,452,912,482,121,821,581,371,191,040,910,790,70
120 mmSuction7,626,285,244,433,783,252,812,442,131,871,641,451,281,131,01
120 mmPressure7,626,285,244,433,783,252,812,442,131,871,641,451,281,131,01
150 mmSuction8,267,086,205,514,964,443,853,282,832,472,171,921,711,541,39
150 mmPressure8,267,086,205,514,964,443,853,282,832,472,171,921,711,541,39
180 mmSuction8,907,636,685,945,344,864,453,953,412,972,612,312,061,851,67
180 mmPressure8,907,636,685,945,344,864,453,953,412,972,612,312,061,851,67
200 mmSuction9,338,007,006,225,605,094,674,313,793,302,902,572,292,061,86
200 mmPressure9,338,007,006,225,605,094,674,313,793,302,902,572,292,061,86

Wall application – multiple support condition

ThicknessLoad1.50 m1.75 m2.00 m2.25 m2.50 m2.75 m3.00 m3.25 m3.50 m3.75 m4.00 m4.25 m4.50 m4.75 m5.00 m
60 mmSuction3,362,752,301,961,681,461,281,131,000,900,800,720,650,580,53
60 mmPressure3,362,752,301,961,681,461,281,131,000,900,800,720,650,580,53
80 mmSuction4,213,613,162,812,492,181,931,711,491,291,141,010,900,810,73
80 mmPressure4,213,613,162,812,492,181,931,711,491,291,141,010,900,810,73
100 mmSuction4,643,983,483,092,782,532,322,141,871,631,431,271,131,020,92
100 mmPressure4,643,983,483,092,782,532,322,141,871,631,431,271,131,020,92
120 mmSuction5,064,343,803,383,042,762,532,342,171,961,731,531,361,221,10
120 mmPressure5,064,343,803,383,042,762,532,342,171,961,731,531,361,221,10
150 mmSuction5,704,894,283,803,423,112,852,632,442,282,141,921,711,541,39
150 mmPressure5,704,894,283,803,423,112,852,632,442,282,141,921,711,541,39
180 mmSuction6,345,444,764,233,813,463,172,932,722,542,382,242,061,851,67
180 mmPressure6,345,444,764,233,813,463,172,932,722,542,382,242,061,851,67
200 mmSuction6,775,805,084,514,063,693,393,132,902,712,542,392,262,061,86
200 mmPressure6,775,805,084,514,063,693,393,132,902,712,542,392,262,061,86

Roof application – single support condition (span 1.50 to 5.00 m)

Thickness1.50 m1.75 m2.00 m2.25 m2.50 m2.75 m3.00 m3.25 m3.50 m3.75 m4.00 m4.25 m4.50 m4.75 m5.00 m
60 mm3,292,612,111,711,411,160,960,800,670,560,470,390,330,270,22
80 mm4,793,883,192,652,221,881,591,361,161,000,860,740,630,550,47
100 mm6,134,994,133,462,922,482,121,821,571,351,171,010,880,770,67
120 mm7,536,295,254,443,793,252,812,442,121,861,631,431,251,110,98
150 mm8,166,986,105,414,684,023,473,012,622,282,001,751,541,351,19
180 mm8,797,526,575,835,234,754,343,843,302,862,502,201,951,741,56
200 mm9,187,856,856,075,454,944,524,163,643,152,752,422,141,911,71

Roof application – continued (span 5.25 to 9.00 m)

Thickness5.25 m5.50 m5.75 m6.00 m6.25 m6.50 m6.75 m7.00 m7.25 m7.50 m7.75 m8.00 m8.25 m8.50 m8.75 m9.00 m
60 mm————————————————
80 mm0,410,350,300,260,22———————————
100 mm0,580,500,440,380,330,290,250,20————————
120 mm0,860,760,670,600,530,470,410,360,320,280,250,22————
150 mm1,040,920,780,640,520,420,330,25————————
180 mm1,401,271,151,050,960,860,770,650,550,460,380,310,24———
200 mm1,531,381,251,141,040,950,870,800,730,670,580,490,410,340,280,22

TECHNICAL DATASHEET

Technical datasheet for freezing cold storage sandwich panel

Consult the technical datasheet with dimensions, materials, thermal behavior, weights, finishes and product load tables.

TECHNICAL IMAGES

Details of the cold storage sandwich panel

Cold storage sandwich panel for cold rooms: tongue-and-groove joint between two panels
Tongue-and-groove joint between two panels, in perspective.
3D view of the cold storage sandwich panel for cold rooms, ribbed faces
Panel in perspective, with ribbed faces.

QUESTIONS

Frequently asked questions about cold storage sandwich panel

The technical datasheet destines it for industrial cold rooms and refrigerated enclosures.

The documentation covers 60, 80, 100, 120, 150, 180 and 200 mm.

The indicated widths are 1,000 and 1,165 mm, with a tolerance of ±2 mm.

The declared transmittance ranges from 0.34 W/m²·K for 60 mm to 0.10 W/m²·K for 200 mm.

The datasheet covers a special PVC coating suitable for food applications.

ACCESSORIES FOR COLD STORAGE PANEL

Accessories and flashings for cold storage sandwich panel

LATEST ARTICLES

Guides and tips on sandwich panel

Consult content on panel selection, insulation, assembly, maintenance, rehabilitation and real applications.

ON-SITE SERVICE

Specialist team for sandwich panel installation

We quote for new builds, refurbishment, roof and facade replacement, flashing installation, and work with sheet metal or skylights.

The quote depends on geometry, height, access, auxiliary equipment, location, fixings and junctions the job must resolve.

Sandwich panel installation on site