PRODUCT DESCRIPTION
The Marseille tile effect sandwich panel is an insulating roof panel with a geometry inspired by traditional roof tiles. It consists of two profiled metal sheets bonded to a rigid polyurethane (PUR) or polyisocyanurate (PIR) core.
Its outer sheet features a textured finish to visually approximate the enclosure to a conventional tiled roof, integrating exterior finish, enclosure, and insulation into a single prefabricated element.
The technical data sheet specifies it for roofs with a minimum pitch of 7%. It has a useful width of 1,000 mm and is manufactured in thicknesses of 40, 60, and 80 mm.
The indicated length ranges from 2.10 to 14.00 m, with a recommended maximum length of 8.05 m.
Insulating panel for roofs with a minimum pitch of 7%. The choice of thickness, fixings, and support spacing must be verified according to the loads and actual conditions of each project.
| Thicknesses | 40, 60, and 80 mm ±2 mm |
|---|---|
| Effective width | 1,000 mm ±2 mm |
| Represented wave spacing | 200 mm |
| Vertical dimension represented in the profile | 21 mm |
| Manufacturing length | 2.10 – 14.00 m |
| Recommended maximum length | 8.05 m |
The textual data sheet indicates manufacturing in multiples of 0.35 m, while the graphic diagram shows a longitudinal dimension of 360 mm. It is advisable to confirm the exact modulation before placing an order.
Tolerances according to EN 14509, in accordance with the provided documentation.
The technical documentation considers a 25 µm textured polyester paint as the standard finish. Special options are also indicated, including a 55 µm coating, an 180 µm PVC interior finish with a wood look, and the possibility of a lacquered aluminum metallic coating.
Among the exterior references shown are RAL 8004T copper brown, RAL 8023T orange brown, and RAL 9005T jet black, in addition to an aged finish with a traditional appearance.
For the interior face, RAL 9010 pure white and decorative wood-look finishes are indicated.
Colors shown on screen are approximate. When the tone is critical, a real sample should be checked before confirming the order.
The installation of the Marseille tile effect sandwich panel must be carried out on a correctly dimensioned structure and respecting a minimum pitch of 7%.
In more severe environments, the documentation recommends applying silicone to the panel joint to help prevent condensation.
Important: the provided technical data sheet does not include load tables. Allowable spans and support spacing must be verified using valid calculation documentation for the project.
DECLARED PERFORMANCE
| Configuration | Insulating roof panel with traditional tile geometry |
|---|---|
| Minimum Pitch | 7% |
| Effective width | 1,000 mm ±2 mm |
| Total Thickness | 40 / 60 / 80 mm |
| Declared Length | 2.10 – 14.00 m |
| Recommended Maximum Length | 8.05 m |
| Sheet | S250GD Galvanized Steel |
| Sheet Thicknesses | 0.4 / 0.5 / 0.6 mm |
| Core | PUR or PIR |
| Core density | 40 kg/m³ |
| Thermal conductivity | 0.0207 W/m·K |
| Fire Reaction | PUR B-s2,d0 · PIR B-s2,d0 · High-Performance PIR B-s1,d0 |
| Tolerances | According to EN 14509 |
The data sheet shows two visual configurations for the exterior face: ribbed and plank effect.
TECHNICAL DATA SHEET
Consult the product’s technical documentation with dimensions, materials, insulation, coatings, and available finishes.
The button link can be replaced with the definitive PDF URL once uploaded to the WordPress library.
QUESTIONS
It is an insulating roof panel with traditional tile geometry, two profiled metal sheets, and an insulating PUR or PIR core.
The provided technical data sheet indicates a minimum pitch of 7%.
The documentation includes thicknesses of 40, 60, and 80 mm, with an indicated tolerance of ±2 mm.
The indicated useful width is 1,000 mm ±2 mm.
The data sheet indicates lengths from 2.10 to 14.00 m and recommends a maximum of 8.05 m. It is advisable to confirm the exact longitudinal modulation before ordering.
No. The documentation provided for this product does not include allowable load tables, so spans and support spacing must be verified with specific calculation documentation.
TRIMS FOR TILE PANEL




LATEST ARTICLES
Explore content on panel selection, insulation, installation, maintenance, refurbishment and real-world applications.
TAMBIÉN TE PUEDE INTERESAR




SERVICIO DE OBRA
Valoramos obra nueva, rehabilitación, sustitución de cubiertas y fachadas, colocación de rematería y trabajos con chapa o lucernarios.
El presupuesto depende de la geometría, altura, accesos, medios auxiliares, ubicación, fijaciones y encuentros que deba resolver la obra.
PRESUPUESTO PERSONALIZADO
Indica tipo de panel, superficie, espesor, localidad y si necesitas suministro o montaje. Revisaremos los datos para preparar una propuesta ajustada.
SOLICITUD RÁPIDA
Completa los datos principales y prepararemos una propuesta ajustada a tu proyecto.