E-mail de contacto
Teléfono de soporte
PANEL SANDWICH · CONFIGURACIÓN Y PRESUPUESTO
Selecciona las opciones disponibles. Te prepararemos el precio según medidas, cantidad, transporte y montaje.
PRODUCT DESCRIPTION
The wood-effect facade sandwich panel combines the warm appearance of a wood-type decorative finish with the technical base of an insulating facade panel with visible fixing. It consists of two profiled metal sheets bonded to a rigid polyurethane (PUR) or polyisocyanurate (PIR) core.
The technical documentation for the base panel covers applications in walls, prefabricated structures, modular construction, and facades, with micro-profiled, ribbed, or smooth surfaces. For this reference, the exterior finish is marketed as wood effect; the final tone and texture must be confirmed with a physical sample and manufacturing availability.
The base panel is manufactured according to EN 14509, in thicknesses from 30 to 100 mm, widths of 1,000 or 1,100 mm, and lengths from 4 to 14 m. The maximum recommended length in the current technical data sheet is 8.00 m.
The joint leaves the screws visible at the panel connection. It is a direct solution for vertical enclosures, with quick assembly on a correctly sized substructure.
| Characteristic | Value |
|---|---|
| Thicknesses | 30, 40, 50, 60, 80, and 100 mm ±2 mm |
| Useful Width | 1,000 or 1,100 mm ±2 mm |
| Production length | 4.00 – 14.00 m ±10 mm |
| Maximum Recommended Length | 8.00 m |
This PanelSandwich.org reference uses the visible-fixing facade panel as a technical base and is configured with a wood-effect exterior finish. The objective is to achieve a warmer-looking facade while maintaining an insulating metal enclosure.
The technical data sheet for the base panel declares 25 µm polyester paint as the standard coating and special finishes Granite HDX 55 µm and PVDF 35 µm. The specific wood decor, its tone, relief, and availability must be confirmed before ordering using a physical sample.
The visual finish alone does not modify the need to verify thicknesses, fixings, wind loads, and spacing between supports for each project.
The wood-effect facade sandwich panel with visible screws must be installed on a plumb and correctly sized structure or substructure. The fixing passes through the panel joint area and remains visible on the facade.
The spacing between supports, the type and number of fixings, and the horizontal or vertical orientation must be defined according to the actual project loads, especially wind pressure and suction.
At joints, corners, openings, and copings, appropriate trims must be used to ensure aesthetic continuity and watertightness.
DECLARED PERFORMANCE
| Thickness (mm) | U (W/m²·K) | Weight 0.4/0.4 (kg/m²) | Weight 0.5/0.5 (kg/m²) |
|---|---|---|---|
| 30 | 0.69 | 7.0 | 8.6 |
| 40 | 0.51 | 7.4 | 9.0 |
| 50 | 0.40 | 7.7 | 9.4 |
| 60 | 0.34 | 8.1 | 9.8 |
| 80 | 0.25 | – | 10.2 |
| 100 | 0.20 | – | 10.6 |
Values declared in the base panel’s technical data sheet. The final choice must correspond to the configuration actually supplied.
The technical data sheet publishes direct calculation tables for spans from 1.50 to 5.00 m, with single and multiple supports and sheet configurations of 0.4/0.4 and 0.5/0.5 mm.
These tables are a technical reference and do not replace project calculations. Deben verificarse las acciones de viento, altura, ubicación, modulación, fijaciones y condiciones reales de la fachada.
Values of uniformly distributed load in kN/m² according to span L. The original table publishes equivalent values for suction and external pressure.
| Thickness (mm) | 1,50 | 1,75 | 2,00 | 2,25 | 2,50 | 2,75 | 3,00 | 3,25 | 3,50 | 3,75 | 4,00 | 4,25 | 4,50 | 4,75 | 5,00 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 30 | 1.31 | 0.79 | 0.41 | ||||||||||||
| 40 | 2,34 | 1,67 | 1,22 | 0,86 | 0,54 | 0,33 | |||||||||
| 50 | 3,45 | 2,56 | 1,92 | 1,46 | 1,12 | 0,87 | 0,61 | 0,41 | |||||||
| 60 | 4,25 | 3,12 | 2,39 | 1,89 | 1,53 | 1,26 | 1,03 | 0,83 | 0,63 | 0,46 | 0,33 | ||||
| 80 | 5,72 | 4,21 | 3,22 | 2,54 | 2,06 | 1,70 | 1,43 | 1,22 | 1,05 | 0,92 | 0,80 | 0,71 | 0,63 | 0,50 | 0,39 |
| 100 | 6,35 | 5,29 | 4,05 | 3,20 | 2,59 | 2,14 | 1,80 | 1,53 | 1,32 | 1,15 | 1,01 | 0,90 | 0,80 | 0,72 | 0,65 |
Values of uniformly distributed load in kN/m² according to span L. The original table publishes equivalent values for suction and external pressure.
| Thickness (mm) | 1,50 | 1,75 | 2,00 | 2,25 | 2,50 | 2,75 | 3,00 | 3,25 | 3,50 | 3,75 | 4,00 | 4,25 | 4,50 | 4,75 | 5,00 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 30 | 2,02 | 1,49 | 1,14 | 0,90 | 0,73 | 0,60 | 0,51 | 0,43 | 0,37 | 0,32 | |||||
| 40 | 2,77 | 2,03 | 1,56 | 1,23 | 1,00 | 0,82 | 0,69 | 0,59 | 0,51 | 0,44 | 0,39 | 0,34 | 0,31 | ||
| 50 | 3,15 | 2,58 | 1,97 | 1,56 | 1,26 | 1,04 | 0,88 | 0,75 | 0,64 | 0,56 | 0,49 | 0,44 | 0,39 | 0,35 | 0,32 |
| 60 | 3,36 | 2,88 | 2,39 | 1,89 | 1,53 | 1,26 | 1,06 | 0,90 | 0,78 | 0,68 | 0,60 | 0,53 | 0,47 | 0,42 | 0,38 |
| 80 | 3,79 | 3,25 | 2,84 | 2,52 | 2,06 | 1,70 | 1,43 | 1,22 | 1,05 | 0,92 | 0,80 | 0,71 | 0,64 | 0,57 | 0,52 |
| 100 | 4,21 | 3,61 | 3,16 | 2,81 | 2,53 | 2,14 | 1,80 | 1,53 | 1,32 | 1,15 | 1,01 | 0,90 | 0,80 | 0,72 | 0,65 |
Values of uniformly distributed load in kN/m² according to span L. The original table publishes equivalent values for suction and external pressure.
| Thickness (mm) | 1,50 | 1,75 | 2,00 | 2,25 | 2,50 | 2,75 | 3,00 | 3,25 | 3,50 | 3,75 | 4,00 | 4,25 | 4,50 | 4,75 | 5,00 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 30 | 1.40 | 0.85 | 0.44 | ||||||||||||
| 40 | 2,47 | 1,79 | 1,31 | 0,93 | 0,60 | 0,36 | |||||||||
| 50 | 3,62 | 2,71 | 2,06 | 1,58 | 1,22 | 0,95 | 0,67 | 0,46 | 0,30 | ||||||
| 60 | 4,49 | 3,68 | 2,83 | 2,23 | 1,77 | 1,41 | 1,13 | 0,92 | 0,70 | 0,52 | 0,37 | ||||
| 80 | 5,92 | 4,98 | 3,81 | 3,01 | 2,44 | 2,01 | 1,69 | 1,44 | 1,24 | 1,08 | 0,95 | 0,83 | 0,70 | 0,56 | 0,44 |
| 100 | 6,34 | 5,44 | 4,76 | 3,79 | 3,07 | 2,54 | 2,13 | 1,82 | 1,57 | 1,36 | 1,20 | 1,06 | 0,95 | 0,85 | 0,77 |
Values of uniformly distributed load in kN/m² according to span L. The original table publishes equivalent values for suction and external pressure.
| Thickness (mm) | 1,50 | 1,75 | 2,00 | 2,25 | 2,50 | 2,75 | 3,00 | 3,25 | 3,50 | 3,75 | 4,00 | 4,25 | 4,50 | 4,75 | 5,00 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 30 | 2,08 | 1,63 | 1,31 | 1,06 | 0,86 | 0,71 | 0,60 | 0,50 | 0,43 | 0,36 | 0,31 | ||||
| 40 | 2,93 | 2,40 | 1,84 | 1,45 | 1,18 | 0,97 | 0,82 | 0,70 | 0,60 | 0,52 | 0,46 | 0,41 | 0,36 | 0,33 | |
| 50 | 3,14 | 2,70 | 2,33 | 1,84 | 1,49 | 1,23 | 1,04 | 0,88 | 0,76 | 0,66 | 0,58 | 0,52 | 0,46 | 0,41 | 0,37 |
| 60 | 3,36 | 2,88 | 2,52 | 2,23 | 1,81 | 1,49 | 1,26 | 1,07 | 0,92 | 0,80 | 0,71 | 0,63 | 0,56 | 0,50 | 0,45 |
| 80 | 3,78 | 3,24 | 2,84 | 2,52 | 2,27 | 2,01 | 1,69 | 1,44 | 1,24 | 1,08 | 0,95 | 0,84 | 0,75 | 0,68 | 0,61 |
| 100 | 4,21 | 3,61 | 3,16 | 2,81 | 2,53 | 2,30 | 2,11 | 1,82 | 1,57 | 1,36 | 1,20 | 1,06 | 0,95 | 0,85 | 0,77 |
TECHNICAL DATA SHEET
Download the technical data sheet for the facade sandwich panel with visible fixing used as the base for this wood-effect finish reference. Includes dimensions, thicknesses, profiles, insulating core, thermal performance, weights, and load tables.
The exact configuration of the wood-effect finish must be confirmed with the order, along with the thickness, PUR/PIR core, and required length.
QUESTIONS
It is an insulating panel for vertical enclosures with a wood-type decorative finish. For this reference, a metal facade panel with a PUR or PIR core and visible fixing is used as the base.
Yes. The base panel uses visible fixing at the joint between panels. The screws and their spacing must be defined according to the support structure and project loads.
The technical data sheet includes thicknesses of 30, 40, 50, 60, 80, and 100 mm, with an indicated tolerance of ±2 mm.
The current technical documentation includes widths of 1,000 and 1,100 mm, both with a tolerance of ±2 mm.
The declared thermal transmittance ranges from 0.69 W/m²·K for 30 mm up to 0.20 W/m²·K for 100 mm. The exact value depends on the selected thickness.
The wood decor must be confirmed before ordering by means of a physical sample or available finish reference. The base panel’s technical data sheet documents the panel’s performance and general coatings but does not define a single wood tone.
FACADE TRIMS
LATEST ARTICLES
Explore content on panel selection, insulation, installation, maintenance, refurbishment and real-world applications.
TAMBIÉN TE PUEDE INTERESAR




SERVICIO DE OBRA
Valoramos obra nueva, rehabilitación, sustitución de cubiertas y fachadas, colocación de rematería y trabajos con chapa o lucernarios.
El presupuesto depende de la geometría, altura, accesos, medios auxiliares, ubicación, fijaciones y encuentros que deba resolver la obra.
PRESUPUESTO PERSONALIZADO
Indica tipo de panel, superficie, espesor, localidad y si necesitas suministro o montaje. Revisaremos los datos para preparar una propuesta ajustada.
SOLICITUD RÁPIDA
Completa los datos principales y prepararemos una propuesta ajustada a tu proyecto.