Contact Email
Support Phone Number
PERSONALISED QUOTE
Tell us the panel type, area, thickness, location and whether you need supply only or installation. We’ll review the details to prepare a tailored proposal.
QUICK REQUEST
Complete the main details and we will prepare a proposal tailored to your project.
PRODUCT DESCRIPTION
The cold room sandwich panel for storage is an insulating enclosure solution aimed at facilities that need to maintain a stable temperature and reduce thermal losses. It consists of two profiled metal sheets bonded to a rigid polyurethane (PUR) or polyisocyanurate (PIR) core.
To differentiate it from panels intended for freezing, this range works with thicknesses from 30 to 100 mm, offering a lighter solution for storage applications, interior enclosures, and areas where the insulation thicknesses typical of freezer rooms are not required.
It is used for walls, prefabricated buildings, modular construction and façades with visible fixing, and is manufactured to EN 14509.
It features effective widths of 1,000 or 1,100 mm and manufacturing lengths between 4.00 and 14.00 m, with 8.00 m as the maximum recommended length.
Product oriented on this page towards refrigerated storage and insulated enclosures. Unlike the freezing solution, which uses higher thicknesses, this range focuses on thicknesses from 30 to 100 mm.
It is suitable for walls, prefabricated buildings, modular construction and façades with visible fixing.
| Thicknesses | 30, 40, 50, 60, 80 and 100 mm ±2 mm |
|---|---|
| Effective width | 1,000 or 1,100 mm ±2 mm |
| Manufacturing length | 4.00 – 14.00 m ±10 mm |
| Maximum recommended length | 8.00 m |
The documentation includes micro-ribbed, ribbed, and smooth finishes.
The indicated standard finish is 25 µm polyester paint. Special 55 µm coatings and 35 µm PVDF finishes are also considered depending on availability and supply conditions.
The indicated range includes RAL 9010, RAL 9006, RAL 9004, RAL 7022, RAL 7016, RAL 7012, RAL 6005, RAL 5010, RAL 3009 and RAL 1015.
Special aged-look finishes for facade applications are also shown.
Colors shown on screen are for guidance only. When the tone is critical, a real sample should be checked before confirming the order.
The installation of the cold room sandwich panel for storage must be carried out on a correctly sized and plumbed sub-structure, ensuring continuity of insulation and correct execution of joints.
Important: allowable spans must be checked using the load tables and the actual conditions of each project.
DECLARED PERFORMANCE
| Product | Cold room sandwich panel for storage |
|---|---|
| Effective width | 1,000 / 1,100 mm ±2 mm |
| Total thickness | 30 / 40 / 50 / 60 / 80 / 100 mm |
| Steel sheet | S250GD · EN 10346 |
| Sheet thicknesses | 0.4 / 0.5 mm |
| Core | PUR or PIR |
| Core density | 40 kg/m³ |
| Thermal conductivity | 0.0207 W/m·K |
| Manufacturing standard | EN 14509 |
| Thickness | 30 mm | 40 mm | 50 mm | 60 mm | 80 mm | 100 mm |
|---|---|---|---|---|---|---|
| U-value (W/m²·K) | 0,69 | 0,51 | 0,40 | 0,34 | 0,25 | 0,20 |
| Weight 0.4/0.4 (kg/m²) | 7,0 | 7,4 | 7,7 | 8,1 | — | — |
| Weight 0.5/0.5 (kg/m²) | 8,6 | 9,0 | 9,4 | 9,8 | 10,2 | 10,6 |
Loads from the technical data sheet in kN/m² according to the span between supports (in metres).
The 0.4/0.4 and 0.5/0.5 configurations are shown for both single and multiple support, differentiating between suction and external pressure.
| Thickness | Load | 1.50 m | 1.75 m | 2.00 m | 2.25 m | 2.50 m | 2.75 m | 3.00 m | 3.25 m | 3.50 m | 3.75 m | 4.00 m | 4.25 m | 4.50 m | 4.75 m | 5.00 m |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 30 mm | Suction | 1,31 | 0,79 | 0,41 | — | — | — | — | — | — | — | — | — | — | — | — |
| 30 mm | Pressure | 1,31 | 0,79 | 0,41 | — | — | — | — | — | — | — | — | — | — | — | — |
| 40 mm | Suction | 2,34 | 1,67 | 1,22 | 0,86 | 0,54 | 0,33 | — | — | — | — | — | — | — | — | — |
| 40 mm | Pressure | 2,34 | 1,67 | 1,22 | 0,86 | 0,54 | 0,33 | — | — | — | — | — | — | — | — | — |
| 50 mm | Suction | 3,45 | 2,56 | 1,92 | 1,46 | 1,12 | 0,87 | 0,61 | 0,41 | — | — | — | — | — | — | — |
| 50 mm | Pressure | 3,45 | 2,56 | 1,92 | 1,46 | 1,12 | 0,87 | 0,61 | 0,41 | — | — | — | — | — | — | — |
| 60 mm | Suction | 4,25 | 3,12 | 2,39 | 1,89 | 1,53 | 1,26 | 1,03 | 0,83 | 0,63 | 0,46 | 0,33 | — | — | — | — |
| 60 mm | Pressure | 4,25 | 3,12 | 2,39 | 1,89 | 1,53 | 1,26 | 1,03 | 0,83 | 0,63 | 0,46 | 0,33 | — | — | — | — |
| 80 mm | Suction | 5,72 | 4,21 | 3,22 | 2,54 | 2,06 | 1,70 | 1,43 | 1,22 | 1,05 | 0,92 | 0,80 | 0,71 | 0,63 | 0,50 | 0,39 |
| 80 mm | Pressure | 5,72 | 4,21 | 3,22 | 2,54 | 2,06 | 1,70 | 1,43 | 1,22 | 1,05 | 0,92 | 0,80 | 0,71 | 0,63 | 0,50 | 0,39 |
| 100 mm | Suction | 6,35 | 5,29 | 4,05 | 3,20 | 2,59 | 2,14 | 1,80 | 1,53 | 1,32 | 1,15 | 1,01 | 0,90 | 0,80 | 0,72 | 0,65 |
| 100 mm | Pressure | 6,35 | 5,29 | 4,05 | 3,20 | 2,59 | 2,14 | 1,80 | 1,53 | 1,32 | 1,15 | 1,01 | 0,90 | 0,80 | 0,72 | 0,65 |
| Thickness | Load | 1.50 m | 1.75 m | 2.00 m | 2.25 m | 2.50 m | 2.75 m | 3.00 m | 3.25 m | 3.50 m | 3.75 m | 4.00 m | 4.25 m | 4.50 m | 4.75 m | 5.00 m |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 30 mm | Suction | 2,02 | 1,49 | 1,14 | 0,90 | 0,73 | 0,60 | 0,51 | 0,43 | 0,37 | 0,32 | — | — | — | — | — |
| 30 mm | Pressure | 2,02 | 1,49 | 1,14 | 0,90 | 0,73 | 0,60 | 0,51 | 0,43 | 0,37 | 0,32 | — | — | — | — | — |
| 40 mm | Suction | 2,77 | 2,03 | 1,56 | 1,23 | 1,00 | 0,82 | 0,69 | 0,59 | 0,51 | 0,44 | 0,39 | 0,34 | 0,31 | — | — |
| 40 mm | Pressure | 2,77 | 2,03 | 1,56 | 1,23 | 1,00 | 0,82 | 0,69 | 0,59 | 0,51 | 0,44 | 0,39 | 0,34 | 0,31 | — | — |
| 50 mm | Suction | 3,15 | 2,58 | 1,97 | 1,56 | 1,26 | 1,04 | 0,88 | 0,75 | 0,64 | 0,56 | 0,49 | 0,44 | 0,39 | 0,35 | 0,32 |
| 50 mm | Pressure | 3,15 | 2,58 | 1,97 | 1,56 | 1,26 | 1,04 | 0,88 | 0,75 | 0,64 | 0,56 | 0,49 | 0,44 | 0,39 | 0,35 | 0,32 |
| 60 mm | Suction | 3,36 | 2,88 | 2,39 | 1,89 | 1,53 | 1,26 | 1,06 | 0,90 | 0,78 | 0,68 | 0,60 | 0,53 | 0,47 | 0,42 | 0,38 |
| 60 mm | Pressure | 3,36 | 2,88 | 2,39 | 1,89 | 1,53 | 1,26 | 1,06 | 0,90 | 0,78 | 0,68 | 0,60 | 0,53 | 0,47 | 0,42 | 0,38 |
| 80 mm | Suction | 3,79 | 3,25 | 2,84 | 2,52 | 2,06 | 1,70 | 1,43 | 1,22 | 1,05 | 0,92 | 0,80 | 0,71 | 0,64 | 0,57 | 0,52 |
| 80 mm | Pressure | 3,79 | 3,25 | 2,84 | 2,52 | 2,06 | 1,70 | 1,43 | 1,22 | 1,05 | 0,92 | 0,80 | 0,71 | 0,64 | 0,57 | 0,52 |
| 100 mm | Suction | 4,21 | 3,61 | 3,16 | 2,81 | 2,53 | 2,14 | 1,80 | 1,53 | 1,32 | 1,15 | 1,01 | 0,90 | 0,80 | 0,72 | 0,65 |
| 100 mm | Pressure | 4,21 | 3,61 | 3,16 | 2,81 | 2,53 | 2,14 | 1,80 | 1,53 | 1,32 | 1,15 | 1,01 | 0,90 | 0,80 | 0,72 | 0,65 |
| Thickness | Load | 1.50 m | 1.75 m | 2.00 m | 2.25 m | 2.50 m | 2.75 m | 3.00 m | 3.25 m | 3.50 m | 3.75 m | 4.00 m | 4.25 m | 4.50 m | 4.75 m | 5.00 m |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 30 mm | Suction | 1,40 | 0,85 | 0,44 | — | — | — | — | — | — | — | — | — | — | — | — |
| 30 mm | Pressure | 1,40 | 0,85 | 0,44 | — | — | — | — | — | — | — | — | — | — | — | — |
| 40 mm | Suction | 2,47 | 1,79 | 1,31 | 0,93 | 0,60 | 0,36 | — | — | — | — | — | — | — | — | — |
| 40 mm | Pressure | 2,47 | 1,79 | 1,31 | 0,93 | 0,60 | 0,36 | — | — | — | — | — | — | — | — | — |
| 50 mm | Suction | 3,62 | 2,71 | 2,06 | 1,58 | 1,22 | 0,95 | 0,67 | 0,46 | 0,30 | — | — | — | — | — | — |
| 50 mm | Pressure | 3,62 | 2,71 | 2,06 | 1,58 | 1,22 | 0,95 | 0,67 | 0,46 | 0,30 | — | — | — | — | — | — |
| 60 mm | Suction | 4,49 | 3,68 | 2,83 | 2,23 | 1,77 | 1,41 | 1,13 | 0,92 | 0,70 | 0,52 | 0,37 | — | — | — | — |
| 60 mm | Pressure | 4,49 | 3,68 | 2,83 | 2,23 | 1,77 | 1,41 | 1,13 | 0,92 | 0,70 | 0,52 | 0,37 | — | — | — | — |
| 80 mm | Suction | 5,92 | 4,98 | 3,81 | 3,01 | 2,44 | 2,01 | 1,69 | 1,44 | 1,24 | 1,08 | 0,95 | 0,83 | 0,70 | 0,56 | 0,44 |
| 80 mm | Pressure | 5,92 | 4,98 | 3,81 | 3,01 | 2,44 | 2,01 | 1,69 | 1,44 | 1,24 | 1,08 | 0,95 | 0,83 | 0,70 | 0,56 | 0,44 |
| 100 mm | Suction | 6,34 | 5,44 | 4,76 | 3,79 | 3,07 | 2,54 | 2,13 | 1,82 | 1,57 | 1,36 | 1,20 | 1,06 | 0,95 | 0,85 | 0,77 |
| 100 mm | Pressure | 6,34 | 5,44 | 4,76 | 3,79 | 3,07 | 2,54 | 2,13 | 1,82 | 1,57 | 1,36 | 1,20 | 1,06 | 0,95 | 0,85 | 0,77 |
| Thickness | Load | 1.50 m | 1.75 m | 2.00 m | 2.25 m | 2.50 m | 2.75 m | 3.00 m | 3.25 m | 3.50 m | 3.75 m | 4.00 m | 4.25 m | 4.50 m | 4.75 m | 5.00 m |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 30 mm | Suction | 2,08 | 1,63 | 1,31 | 1,06 | 0,86 | 0,71 | 0,60 | 0,50 | 0,43 | 0,36 | 0,31 | — | — | — | — |
| 30 mm | Pressure | 2,08 | 1,63 | 1,31 | 1,06 | 0,86 | 0,71 | 0,60 | 0,50 | 0,43 | 0,36 | 0,31 | — | — | — | — |
| 40 mm | Suction | 2,93 | 2,40 | 1,84 | 1,45 | 1,18 | 0,97 | 0,82 | 0,70 | 0,60 | 0,52 | 0,46 | 0,41 | 0,36 | 0,33 | — |
| 40 mm | Pressure | 2,93 | 2,40 | 1,84 | 1,45 | 1,18 | 0,97 | 0,82 | 0,70 | 0,60 | 0,52 | 0,46 | 0,41 | 0,36 | 0,33 | — |
| 50 mm | Suction | 3,14 | 2,70 | 2,33 | 1,84 | 1,49 | 1,23 | 1,04 | 0,88 | 0,76 | 0,66 | 0,58 | 0,52 | 0,46 | 0,41 | 0,37 |
| 50 mm | Pressure | 3,14 | 2,70 | 2,33 | 1,84 | 1,49 | 1,23 | 1,04 | 0,88 | 0,76 | 0,66 | 0,58 | 0,52 | 0,46 | 0,41 | 0,37 |
| 60 mm | Suction | 3,36 | 2,88 | 2,52 | 2,23 | 1,81 | 1,49 | 1,26 | 1,07 | 0,92 | 0,80 | 0,71 | 0,63 | 0,56 | 0,50 | 0,45 |
| 60 mm | Pressure | 3,36 | 2,88 | 2,52 | 2,23 | 1,81 | 1,49 | 1,26 | 1,07 | 0,92 | 0,80 | 0,71 | 0,63 | 0,56 | 0,50 | 0,45 |
| 80 mm | Suction | 3,78 | 3,24 | 2,84 | 2,52 | 2,27 | 2,01 | 1,69 | 1,44 | 1,24 | 1,08 | 0,95 | 0,84 | 0,75 | 0,68 | 0,61 |
| 80 mm | Pressure | 3,78 | 3,24 | 2,84 | 2,52 | 2,27 | 2,01 | 1,69 | 1,44 | 1,24 | 1,08 | 0,95 | 0,84 | 0,75 | 0,68 | 0,61 |
| 100 mm | Suction | 4,21 | 3,61 | 3,16 | 2,81 | 2,53 | 2,30 | 2,11 | 1,82 | 1,57 | 1,36 | 1,20 | 1,06 | 0,95 | 0,85 | 0,77 |
| 100 mm | Pressure | 4,21 | 3,61 | 3,16 | 2,81 | 2,53 | 2,30 | 2,11 | 1,82 | 1,57 | 1,36 | 1,20 | 1,06 | 0,95 | 0,85 | 0,77 |
TECHNICAL DATASHEET
Consult the technical datasheet with dimensions, materials, thermal performance, weights, finishes, and load tables.
QUESTIONS
In this storage range, thicknesses from 30 to 100 mm are used. The freezing solution published separately works with thicknesses up to 200 mm for higher insulation requirements.
The technical datasheet includes 30, 40, 50, 60, 80 and 100 mm.
The declared widths are 1,000 and 1,100 mm, with a tolerance of ±2 mm.
The declared transmittance ranges from 0.69 W/m²·K at 30 mm to 0.20 W/m²·K at 100 mm.
The datasheet includes micro-ribbed, ribbed, and smooth finishes.
ACCESSORIES FOR COLD ROOM PANEL
LATEST ARTICLES
Consult content on panel selection, insulation, assembly, maintenance, rehabilitation, and real applications.
YOU MAY ALSO BE INTERESTED IN
ON-SITE SERVICE
We quote for new builds, refurbishment, roof and facade replacement, flashing installation, and work with sheet metal or skylights.
The quote depends on geometry, height, access, auxiliary equipment, location, fixings and junctions the job must resolve.