PRODUCT DESCRIPTION
The green tile-effect sandwich panel is an insulating roof panel with a geometry inspired by traditional tiles. It consists of two profiled metal sheets and a rigid polyurethane (PUR) or polyisocyanurate (PIR) core.
The exterior sheet incorporates a textured finish that improves the visual similarity to a conventional tile roof. The green RAL 6005 finish offers a uniform colour that integrates well into rural environments, agricultural warehouses, and mountain area constructions.
It is suitable for roofs with a minimum slope of 10%. The effective width is 1,000 mm and it is manufactured in thicknesses of 30, 40, and 50 mm.
The manufacturing length is between 2.10 and 14.00 m in multiples of 0.35 m, with a maximum recommended length of 8.05 m.
The PUR or PIR core has a declared thermal conductivity of 0.0207 W/m·K and a density of 40 kg/m³.
Insulating panel for roofs with a minimum slope of 10%. Its geometry reproduces the shape of a tile roof and combines exterior finish, enclosure, and insulation in a single prefabricated element.
| Thicknesses | 30, 40, and 50 mm ±2 mm |
|---|---|
| Effective width | 1,000 mm ±2 mm |
| Longitudinal module | 350 mm |
| Approximate profile spacing | 200 mm |
| Approximate wave height | 50 mm |
| Manufacturing length | 2.10 – 14.00 m, in multiples of 0.35 m |
| Maximum recommended length | 8.05 m |
The standard exterior finish is 25 µm textured polyester paint. The exterior finish of this product is green RAL 6005.
The range of tile-effect panels also includes other exterior finishes, such as RAL 8004 tile red, RAL 7022 slate grey, aged red, or aged albero.
For the interior face, RAL 9010 pure white, textured wood finish, and other decorative finishes are available. The possibility of a lacquered aluminium metal coating is also indicated.
Colours displayed on screen are for guidance only. When the tone is critical, an actual sample should be checked before confirming the order.
The installation of the green tile-effect sandwich panel must be carried out on a correctly dimensioned structure with a minimum slope of 10%.
In harsher environments, the technical documentation recommends applying silicone to the panel joint to help prevent condensation.
Important: allowable spans must be verified using the load tables and the actual conditions of each roof.
DECLARED PERFORMANCE
| Configuration | Tile-effect insulated roof panel |
|---|---|
| Manufacturing standard | EN 14509 · CE marking |
| Minimum slope | 10% |
| Thicknesses | 30, 40 and 50 mm (±2 mm) |
| Useful width | 1,000 mm (±2 mm) |
| Length | 2.10 to 14.00 m, made to measure in multiples of 0.35 m · recommended up to 8.05 m |
| Wave | 50 mm high · 200 mm pitch · 350 mm longitudinal module |
| Steel sheet | S250GD, galvanised |
| Sheet thicknesses | 0.4 / 0.5 / 0.6 mm |
| Core | PUR or PIR · 40 kg/m³ |
| Thermal conductivity | λ = 0.0207 W/m·K |
| Reaction to fire | High-performance PIR: B-s1,d0 · PUR: not certified |
| Coating | 25 µm textured polyester · 55 µm special coating |
| Inner face | Ribbed or planked profile · optional 180 µm wood-effect PVC or pre-painted aluminium |
| Colours | RAL 6005 green, textured · inner face RAL 9010 or planked wood finish · other RAL colours on request |
| Thickness | U-transmittance (W/m²·K) | Weight 0.5/0.4 (kg/m²) | Weight 0.5/0.5 (kg/m²) |
|---|---|---|---|
| 30 mm | 0.45 | 10.8 | 11.7 |
| 40 mm | 0.37 | 11.2 | 12.1 |
| 50 mm | 0.31 | 11.6 | 12.5 |
The technical data sheet includes tables for uniformly distributed loads for spans from 1.05 to 3.50 m, differentiating between upward and downward load, single or multiple support, and 0.5/0.4 and 0.5/0.5 mm sheet configurations.
These tables are a technical reference and do not replace project calculations. Actual wind, snow, and maintenance loads, the number of supports, and specific roof conditions must be verified.
Slide the table
| Thickness | Load | Allowable load (kN/m²) according to distance between supports L (m) | |||||||
|---|---|---|---|---|---|---|---|---|---|
| 1.05 m | 1.40 m | 1.75 m | 2.10 m | 2.45 m | 2.80 m | 3.15 m | 3.50 m | ||
| 30 mm | ▲ | 2,52 | 1,55 | 1,08 | 0,81 | 0,64 | 0,52 | 0,44 | 0,37 |
| ▼ | 1,86 | 1,10 | 0,73 | 0,51 | 0,37 | — | — | — | |
| 40 mm | ▲ | 2,69 | 1,70 | 1,21 | 0,92 | 0,73 | 0,60 | 0,51 | 0,43 |
| ▼ | 1,98 | 1,20 | 0,81 | 0,59 | 0,44 | 0,33 | — | — | |
| 50 mm | ▲ | 2,86 | 1,85 | 1,35 | 1,04 | 0,84 | 0,69 | 0,58 | 0,50 |
| ▼ | 2,11 | 1,32 | 0,91 | 0,67 | 0,50 | 0,39 | 0,30 | — | |
Slide the table
| Thickness | Load | Allowable load (kN/m²) according to distance between supports L (m) | |||||||
|---|---|---|---|---|---|---|---|---|---|
| 1.05 m | 1.40 m | 1.75 m | 2.10 m | 2.45 m | 2.80 m | 3.15 m | 3.50 m | ||
| 30 mm | ▲ | 2,52 | 1,53 | 0,96 | 0,67 | 0,50 | 0,40 | 0,33 | — |
| ▼ | 1,86 | 1,10 | 0,73 | 0,51 | 0,37 | — | — | — | |
| 40 mm | ▲ | 2,69 | 1,68 | 1,07 | 0,73 | 0,54 | 0,43 | 0,35 | — |
| ▼ | 1,86 | 1,10 | 0,73 | 0,51 | 0,37 | — | — | — | |
| 50 mm | ▲ | 2,86 | 1,85 | 1,20 | 0,82 | 0,63 | 0,50 | 0,40 | — |
| ▼ | 1,86 | 1,10 | 0,73 | 0,51 | 0,37 | — | — | — | |
Slide the table
| Thickness | Load | Allowable load (kN/m²) according to distance between supports L (m) | |||||||
|---|---|---|---|---|---|---|---|---|---|
| 1.05 m | 1.40 m | 1.75 m | 2.10 m | 2.45 m | 2.80 m | 3.15 m | 3.50 m | ||
| 30 mm | ▲ | 2,52 | 1,55 | 1,08 | 0,81 | 0,64 | 0,53 | 0,44 | 0,38 |
| ▼ | 1,86 | 1,10 | 0,73 | 0,51 | 0,38 | — | — | — | |
| 40 mm | ▲ | 2,69 | 1,70 | 1,21 | 0,93 | 0,74 | 0,61 | 0,51 | 0,44 |
| ▼ | 1,98 | 1,21 | 0,82 | 0,59 | 0,44 | 0,33 | — | — | |
| 50 mm | ▲ | 2,87 | 1,86 | 1,35 | 1,05 | 0,84 | 0,70 | 0,59 | 0,51 |
| ▼ | 2,11 | 1,32 | 0,92 | 0,67 | 0,51 | 0,39 | 0,30 | — | |
Slide the table
| Thickness | Load | Allowable load (kN/m²) according to distance between supports L (m) | |||||||
|---|---|---|---|---|---|---|---|---|---|
| 1.05 m | 1.40 m | 1.75 m | 2.10 m | 2.45 m | 2.80 m | 3.15 m | 3.50 m | ||
| 30 mm | ▲ | 2,52 | 1,54 | 0,97 | 0,68 | 0,50 | 0,40 | 0,33 | — |
| ▼ | 1,86 | 1,10 | 0,73 | 0,51 | 0,38 | — | — | — | |
| 40 mm | ▲ | 2,69 | 1,69 | 1,08 | 0,73 | 0,54 | 0,43 | 0,35 | — |
| ▼ | 1,98 | 1,21 | 0,82 | 0,59 | 0,44 | 0,33 | — | — | |
| 50 mm | ▲ | 2,87 | 1,86 | 1,21 | 0,82 | 0,63 | 0,50 | 0,40 | 0,30 |
| ▼ | 2,11 | 1,32 | 0,92 | 0,67 | 0,51 | 0,39 | 0,30 | — | |
TECHNICAL DATA SHEET
Download the complete technical data sheet for the green tile-effect sandwich panel to consult dimensions, thicknesses, modulation, thermal performance, weights, colours, finishes, and load tables.
The document should be used as a technical reference along with the specific conditions of each project.
QUESTIONS
It is an insulating roof panel with a geometry inspired by traditional tiles and a textured exterior finish. The green RAL 6005 finish offers a uniform colour for roofs seeking to integrate into the environment.
The minimum slope indicated in the technical data sheet is 10%. The project must also consider the geometry, joints, flashing, and the climatic conditions of the site.
The technical documentation includes thicknesses of 30, 40, and 50 mm, with an indicated tolerance of ±2 mm.
The declared thermal transmittance is 0.45 W/m²·K for 30 mm, 0.37 W/m²·K for 40 mm, and 0.31 W/m²·K for 50 mm.
The manufacturing length ranges from 2.10 to 14.00 m in multiples of 0.35 m. The maximum recommended length indicated in the sheet is 8.05 m.
In addition to green, the sheet includes RAL 8004 tile red, RAL 8023 light tile red, RAL 9005 jet black, and various aged or decorative finishes. For the interior face, RAL 9010 pure white and textured wood finish are included.
FLASHING FOR TILE PANEL
LATEST ARTICLES
Consult content on panel selection, insulation, assembly, maintenance, rehabilitation, and real-world applications.
YOU MAY ALSO BE INTERESTED IN
ON-SITE SERVICE
We quote for new builds, refurbishment, roof and facade replacement, flashing installation, and work with sheet metal or skylights.
The quote depends on geometry, height, access, auxiliary equipment, location, fixings and junctions the job must resolve.