PRODUCT DESCRIPTION
The aged red tile effect sandwich panel is an insulating roof panel with geometry inspired by traditional tiles. It consists of two profiled metal sheets and a rigid core of polyurethane (PUR) or polyisocyanurate (PIR).
The outer sheet incorporates a textured finish that improves the visual similarity to a conventional tile roof. The aged red finish gives the roof a traditional tile appearance, with less uniform colour nuances than a plain red.
It is suitable for roofs with a minimum slope of 10%. The useful width is 1,000 mm and it is manufactured in thicknesses of 30, 40 and 50 mm.
The manufacturing length is between 2.10 and 14.00 m in multiples of 0.35 m, with a recommended maximum length of 8.05 m.
The PUR or PIR core has a declared thermal conductivity of 0.0207 W/m·K and a density of 40 kg/m³.
Insulating panel for roofs with a minimum slope of 10%. Its geometry reproduces the shape of a tile roof and combines exterior finish, enclosure and insulation in a single prefabricated element.
| Thicknesses | 30, 40 and 50 mm ±2 mm |
|---|---|
| Useful width | 1,000 mm ±2 mm |
| Longitudinal module | 350 mm |
| Approximate profile spacing | 200 mm |
| Approximate wave height | 50 mm |
| Manufacturing length | 2.10 – 14.00 m, in multiples of 0.35 m |
| Recommended maximum length | 8.05 m |
The standard exterior finish is 25 µm textured polyester paint. The exterior finish of this product is aged red.
Available colour: aged red, with the inner face in RAL 9010 or a planked wood finish. Other RAL colours on request.
For the interior face, RAL 9010 pure white, textured wood finish and other decorative finishes are included. The possibility of metal coating in lacquered aluminium is also indicated.
Colours displayed on screen are for guidance only. When the shade is critical, a real sample must be checked before confirming the order.
The installation of the aged red tile effect sandwich panel must be carried out on a correctly dimensioned structure and with a minimum slope of 10%.
In more severe environments, the technical documentation recommends applying silicone to the panel joint to help prevent condensation.
Important: the admissible spans must be checked using the load tables and the actual conditions of each roof.
DECLARED PERFORMANCE
| Configuration | Tile-effect insulated roof panel |
|---|---|
| Manufacturing standard | EN 14509 · CE marking |
| Minimum slope | 10% |
| Thicknesses | 30, 40 and 50 mm (±2 mm) |
| Useful width | 1,000 mm (±2 mm) |
| Length | 2.10 to 14.00 m, made to measure in multiples of 0.35 m · recommended up to 8.05 m |
| Wave | 50 mm high · 200 mm pitch · 350 mm longitudinal module |
| Steel sheet | S250GD, galvanised |
| Sheet thicknesses | 0.4 / 0.5 / 0.6 mm |
| Core | PUR or PIR · 40 kg/m³ |
| Thermal conductivity | λ = 0.0207 W/m·K |
| Reaction to fire | High-performance PIR: B-s1,d0 · PUR: not certified |
| Coating | 25 µm textured polyester · 55 µm special coating |
| Inner face | Ribbed or planked profile · optional 180 µm wood-effect PVC or pre-painted aluminium |
| Colours | Aged red, textured · inner face RAL 9010 or planked wood finish · other RAL colours on request |
| Thickness | U-value (W/m²·K) | Weight 0.5/0.4 (kg/m²) | Weight 0.5/0.5 (kg/m²) |
|---|---|---|---|
| 30 mm | 0.45 | 10.8 | 11.7 |
| 40 mm | 0.37 | 11.2 | 12.1 |
| 50 mm | 0.31 | 11.6 | 12.5 |
The technical data sheet includes uniformly distributed load tables for spans from 1.05 to 3.50 m, differentiating upward and downward load, simple or multiple support and 0.5/0.4 and 0.5/0.5 mm sheet configurations.
These tables are a technical reference and do not replace project calculations. The actual loads of wind, snow, maintenance, number of supports and specific roof conditions must be verified.
Scroll the table
| Thickness | Load | Admissible load (kN/m²) according to distance between supports L (m) | |||||||
|---|---|---|---|---|---|---|---|---|---|
| 1.05 m | 1.40 m | 1.75 m | 2.10 m | 2.45 m | 2.80 m | 3.15 m | 3.50 m | ||
| 30 mm | ▲ | 2,52 | 1,55 | 1,08 | 0,81 | 0,64 | 0,52 | 0,44 | 0,37 |
| ▼ | 1,86 | 1,10 | 0,73 | 0,51 | 0,37 | — | — | — | |
| 40 mm | ▲ | 2,69 | 1,70 | 1,21 | 0,92 | 0,73 | 0,60 | 0,51 | 0,43 |
| ▼ | 1,98 | 1,20 | 0,81 | 0,59 | 0,44 | 0,33 | — | — | |
| 50 mm | ▲ | 2,86 | 1,85 | 1,35 | 1,04 | 0,84 | 0,69 | 0,58 | 0,50 |
| ▼ | 2,11 | 1,32 | 0,91 | 0,67 | 0,50 | 0,39 | 0,30 | — | |
Scroll the table
| Thickness | Load | Admissible load (kN/m²) according to distance between supports L (m) | |||||||
|---|---|---|---|---|---|---|---|---|---|
| 1.05 m | 1.40 m | 1.75 m | 2.10 m | 2.45 m | 2.80 m | 3.15 m | 3.50 m | ||
| 30 mm | ▲ | 2,52 | 1,53 | 0,96 | 0,67 | 0,50 | 0,40 | 0,33 | — |
| ▼ | 1,86 | 1,10 | 0,73 | 0,51 | 0,37 | — | — | — | |
| 40 mm | ▲ | 2,69 | 1,68 | 1,07 | 0,73 | 0,54 | 0,43 | 0,35 | — |
| ▼ | 1,86 | 1,10 | 0,73 | 0,51 | 0,37 | — | — | — | |
| 50 mm | ▲ | 2,86 | 1,85 | 1,20 | 0,82 | 0,63 | 0,50 | 0,40 | — |
| ▼ | 1,86 | 1,10 | 0,73 | 0,51 | 0,37 | — | — | — | |
Scroll the table
| Thickness | Load | Admissible load (kN/m²) according to distance between supports L (m) | |||||||
|---|---|---|---|---|---|---|---|---|---|
| 1.05 m | 1.40 m | 1.75 m | 2.10 m | 2.45 m | 2.80 m | 3.15 m | 3.50 m | ||
| 30 mm | ▲ | 2,52 | 1,55 | 1,08 | 0,81 | 0,64 | 0,53 | 0,44 | 0,38 |
| ▼ | 1,86 | 1,10 | 0,73 | 0,51 | 0,38 | — | — | — | |
| 40 mm | ▲ | 2,69 | 1,70 | 1,21 | 0,93 | 0,74 | 0,61 | 0,51 | 0,44 |
| ▼ | 1,98 | 1,21 | 0,82 | 0,59 | 0,44 | 0,33 | — | — | |
| 50 mm | ▲ | 2,87 | 1,86 | 1,35 | 1,05 | 0,84 | 0,70 | 0,59 | 0,51 |
| ▼ | 2,11 | 1,32 | 0,92 | 0,67 | 0,51 | 0,39 | 0,30 | — | |
Scroll the table
| Thickness | Load | Admissible load (kN/m²) according to distance between supports L (m) | |||||||
|---|---|---|---|---|---|---|---|---|---|
| 1.05 m | 1.40 m | 1.75 m | 2.10 m | 2.45 m | 2.80 m | 3.15 m | 3.50 m | ||
| 30 mm | ▲ | 2,52 | 1,54 | 0,97 | 0,68 | 0,50 | 0,40 | 0,33 | — |
| ▼ | 1,86 | 1,10 | 0,73 | 0,51 | 0,38 | — | — | — | |
| 40 mm | ▲ | 2,69 | 1,69 | 1,08 | 0,73 | 0,54 | 0,43 | 0,35 | — |
| ▼ | 1,98 | 1,21 | 0,82 | 0,59 | 0,44 | 0,33 | — | — | |
| 50 mm | ▲ | 2,87 | 1,86 | 1,21 | 0,82 | 0,63 | 0,50 | 0,40 | 0,30 |
| ▼ | 2,11 | 1,32 | 0,92 | 0,67 | 0,51 | 0,39 | 0,30 | — | |
TECHNICAL DATA SHEET
Download the complete technical data sheet for the aged red tile effect sandwich panel to consult dimensions, thicknesses, modulation, thermal performance, weights, colours, finishes and load tables.
The document must be used as a technical reference together with the specific conditions of each project.
QUESTIONS
It is an insulating roof panel with geometry inspired by traditional tiles and textured exterior finish. The aged red finish gives it a traditional tile appearance.
The minimum slope indicated in the technical data sheet is 10%. The project must also consider the geometry, junctions, flashing and climatic conditions of the site.
The technical documentation includes thicknesses of 30, 40 and 50 mm, with an indicated tolerance of ±2 mm.
The declared thermal transmittance is 0.45 W/m²·K at 30 mm, 0.37 W/m²·K at 40 mm and 0.31 W/m²·K at 50 mm.
The manufacturing length ranges from 2.10 to 14.00 m in multiples of 0.35 m. The recommended maximum length indicated in the data sheet is 8.05 m.
In addition to aged red, the data sheet includes RAL 8004 tile red, RAL 8023 light tile red, RAL 9005 jet black and various aged or decorative finishes. For the interior face, RAL 9010 pure white and textured wood finish are included.
FLASHING FOR TILE EFFECT PANEL
LATEST ARTICLES
Consult content on panel selection, insulation, assembly, maintenance, refurbishment and real applications.
YOU MAY ALSO BE INTERESTED IN