Description: Roof Lifeline System

Fixed horizontal lifeline to protect people working on sandwich panel roofs, industrial buildings and other roofs against falls: installation, maintenance, cleaning or fitting solar panels. It is an 8 mm stainless steel cable permanently installed on the roof, with end anchors, intermediate brackets and, where needed, curves. Up to six people can be clipped on at the same time, and it can be fixed to the building structure or, with suitable anchors, to sandwich panels.

Characteristics

TypeFixed horizontal cable lifeline (type C anchor device)
Cable8 mm stainless steel, 7 × 7, minimum breaking load 36 kN
UsersUp to 6 at a time
VersionsWith traversable intermediate brackets (the traveller passes them without unclipping) or non-traversable
ComponentsCable, energy absorber, tensioner, end terminals, intermediate brackets, curves, anchors and traveller
Distance between brackets2 to 10 m, depending on the anchor
Line lengthMade to measure, up to 200 m
Deflection in a fallUp to 2.5 m
Force on the end anchorsUp to 9.2 kN with 6 users
SubstratesConcrete, steel, timber, trapezoidal sheet and sandwich panel, with the right anchor for each
StandardsEN 795:2012 type C and CEN/TS 16415 (use by several people at the same time)
ApprovalGerman technical approval (DIBt)

What else you need

The lifeline is only one part of the fall-arrest system. Each worker also needs a full-body harness (EN 361) and a lanyard with an energy absorber (EN 354 and EN 355), adjustable or no longer than 2 m, that limits the arrest force to 6 kN. On the traversable version, the lanyard is clipped to the traveller of the line. Self-retracting fall arresters (EN 360) may only be used if they are models approved by the manufacturer for this system. The line is not suitable for work in suspension, work positioning or hanging loads.

How to install it

  1. It is installed by qualified personnel, following the installation instructions of the manufacturer and using the fixings supplied with the system. The cable of the traversable version and the terminals crimped on site may only be fitted by personnel trained and certified by the manufacturer.
  2. The end, corner and intermediate anchors are fixed to the building structure (steel, concrete or timber). On sandwich panel roofs, anchors suitable for this substrate are used: some pass through the panel and are screwed to the structure below, and others are riveted to the ribs with sealed rivets.
  3. The substrate must withstand the loads transmitted by the line. If in doubt, have it checked by a structural engineer.
  4. The cable is tensioned with the tensioner to the pretension shown on the scale of the energy absorber, with spans of 2 to 10 m between anchors, intermediate brackets and curves.
  5. Check that there is enough clearance below the roof. It is the sum of the cable deflection (up to 2.5 m), the extension of the energy absorber and lanyard, the harness displacement, the height of the user and a 1 m safety margin. If there is not enough clearance, the line may only be used as a restraint system and must be marked as such.
  6. When the work is finished, the installer completes the installation documentation (with photos and a plan showing the position of the anchors) and hands it to the building owner, who keeps a copy in the building. The installer also fills in the system sign of the line and the inspection log card.

Inspection and maintenance

  • Before each use, visually check the cable, anchors, intermediate brackets and traveller, and check on the system sign that the last inspection is up to date. If you see loose, deformed or damaged parts, do not use it.
  • A competent person must inspect it at least every 12 months and record the inspection in writing. The manufacturer recommends an inspector trained and certified by the manufacturer.
  • No load tests are carried out on site.
  • If the line has arrested a fall, withdraw it from service. A qualified person must inspect the line and its substrate, in writing, and the necessary parts, or the whole line with its anchors, are replaced.
  • Clean it from time to time with warm water, without aggressive products, and keep the stainless steel away from ordinary steel (for example, grinding dust) and chemicals.
  • Do not modify it without the permission of the manufacturer and use only original parts.

Frequently asked questions

How many people can be clipped on at the same time?

Up to six, each with their own harness and energy-absorbing lanyard. The line has been tested to EN 795:2012 type C and CEN/TS 16415, which covers use by several people at the same time.

Can it be used as a permanent lifeline?

Yes. It is a permanent line: it is installed on the roof for good, on the building structure or with anchors suitable for sandwich panels, and stays in place for all future work.

What else needs protecting on the roof?

Rooflights and skylights, which are not walkable. For that we offer rooflight fall protection.

See also all mounting accessories. Need a price? Ask for a quote or call us on +34 699 147 762 · WhatsApp.

ON-SITE SERVICE

Specialist team for sandwich panel installation

We quote for new builds, refurbishment, roof and facade replacement, flashing installation, and work with sheet metal or skylights.

The quote depends on geometry, height, access, auxiliary equipment, location, fixings and junctions the job must resolve.

Sandwich panel installation on site