ROCK WOOL SANDWICH PANEL

Acoustic Rock Wool Sandwich Panel for Facade · Visible Fixing

Acoustic Rock Wool Sandwich Panel for Facade · Visible Fixing: description and applications

The acoustic rock wool sandwich panel for facade with visible fixing is an enclosure with a rock wool core, visible mechanical fixing, and a perforated inner face, designed to combine thermal insulation with acoustic control and absorption.

The panel has a useful width of 1,000 mm and is manufactured in thicknesses of 30, 40, 50, 60, 75, 80, 100, 120, 150 mm, with custom lengths between 2 and 15 m.

Characteristics of the acoustic rock wool sandwich panel for facade with visible fixing

Configuration

Panel with rock wool insulating core, double metal face, and visible fixing. The standard core density is 100 kg/m³ and the declared thermal conductivity is 0.042 W/m·°C.

Metal supports

  • Standard steel: minimum S220GD.
  • Standard exterior thickness: 0.50 mm.
  • Standard interior thickness: 0.45 mm; in the visible facade family, 0.40-0.50 mm can be supplied.
  • Standard organic coating: 25 µm polyester.

Coatings, finishes, and colors

The standard configuration includes a minimum Z140 g/m² metallic coating and a 25 µm organic polyester finish. Higher metallic protections and PVDF, PUR-PA, HPS, or other finishes can be specified upon request.

Color availability must be confirmed before ordering using the current range.

Installation of the acoustic rock wool sandwich panel for facade with visible fixing

Installation must be carried out on a correctly dimensioned structure, respecting the modulation, fixings, and joints corresponding to the system.

  • Verify span between supports and wind loads.
  • Use fixings suitable for the support and panel thickness.
  • Correctly resolve joints, intersections, and flashings.
  • Avoid damage to coatings during handling.

DECLARED PERFORMANCE

Technical data of the acoustic rock wool sandwich panel for facade with visible fixing

Technical data of the acoustic rock wool sandwich panel for facade with visible fixing

Useful width1,000 mm
Total width1,017 mm
LengthCustom, between 2 and 15 m
Thicknesses30 / 40 / 50 / 60 / 75 / 80 / 100 / 120 / 150 mm
CoreRock wool · 100 kg/m³ standard
Conductivity0.042 W/m·°C

Performance by thickness

Property30 mm40 mm50 mm60 mm75 mm80 mm100 mm120 mm150 mm
Weight (kg/m²)10,5011,5012,5013,5015,0015,5017,5019,5022,50
R (m²·K/W)0,710,951,191,431,791,902,382,863,57
U (W/m²·K)1,130,890,740,630,510,480,390,330,27
Rw insulationNDNDNDNDNDNDNDNDND
Reaction to fireNDNDA2-s1,d0A2-s1,d0A2-s1,d0A2-s1,d0A2-s1,d0A2-s1,d0A2-s1,d0
Fire resistanceNDNDNDNDNDNDNDNDND

Declared performance

The current official technical datasheet does not publish a table of allowable loads for this product; therefore, no undocumented values are included.

TECHNICAL DATASHEET

Technical datasheet · Acoustic Rock Wool Sandwich Panel for Facade · Visible Fixing

Download the technical datasheet for the acoustic rock wool sandwich panel for facade with visible fixing with the dimensions and performance declared for this configuration.

TECHNICAL IMAGES

Technical details · Acoustic Rock Wool Sandwich Panel for Facade · Visible Fixing

QUESTIONS

Frequently asked questions about acoustic rock wool sandwich panel for facade with visible fixing

It is a facade panel with a rock wool core, visible fixing, and a perforated inner face. The official technical datasheet documents thermal, acoustic, and fire behavior performance according to thickness.

30, 40, 50, 60, 75, 80, 100, 120, 150 mm.

Standard 100 kg/m³ rock wool, with a declared thermal conductivity of 0.042 W/m·°C.

A2-s1,d0 for thicknesses from 50 to 150 mm. It is not determined for 30 and 40 mm.

αw = 1.00 · Class A (tested configurations)

No. Ask us for the maximum span between supports for your thickness and project and we will tell you.

ACCESSORIES AND FLASHINGS

Accessories for acoustic rock wool sandwich panel for facade with visible fixing

TECHNICAL INFORMATION

Guides on rock wool sandwich panels

When choosing an acoustic rock wool sandwich panel for facade with visible fixing, compare the thickness, U-value, Rw insulation, and declared acoustic performance. Also see our technical information on sandwich panels.

ON-SITE SERVICE

Specialist team for sandwich panel installation

We quote for new builds, refurbishment, roof and facade replacement, flashing installation, and work with sheet metal or skylights.

The quote depends on geometry, height, access, auxiliary equipment, location, fixings and junctions the job must resolve.

Sandwich panel installation on site