PRODUCT DESCRIPTION
The plain red tile-effect sandwich panel is an insulating roof panel with a geometry inspired by traditional roof tiles. It consists of two profiled metal sheets and a rigid polyurethane (PUR) or polyisocyanurate (PIR) core.
The outer sheet features a textured finish that enhances the visual resemblance to a conventional tile roof. The plain red finish (RAL 8004 shade) offers a uniform colour, without the shading effect of aged finishes.
It is suitable for roofs with a minimum slope of 10%. The usable width is 1,000 mm and it is manufactured in thicknesses of 30, 40 and 50 mm.
Manufacturing length ranges from 2.10 to 14.00 m in multiples of 0.35 m, with a recommended maximum length of 8.05 m.
The PUR or PIR core has a declared thermal conductivity of 0.0207 W/m·K and a density of 40 kg/m³.
Insulating panel for roofs with a minimum slope of 10%. Its geometry replicates the shape of a tile roof and combines exterior finish, enclosure and insulation in a single prefabricated element.
| Thicknesses | 30, 40 and 50 mm ±2 mm |
|---|---|
| Usable width | 1,000 mm ±2 mm |
| Longitudinal module | 350 mm |
| Approximate profile spacing | 200 mm |
| Approximate wave height | 50 mm |
| Manufacturing length | 2.10 – 14.00 m, in multiples of 0.35 m |
| Recommended maximum length | 8.05 m |
The standard exterior finish is 25 µm textured polyester paint. The exterior finish of this product is plain red, RAL 8004 shade.
The range of tile-effect panels also includes other exterior finishes, such as aged red, aged sandstone, slate grey RAL 7022 or green.
For the interior face, RAL 9010 pure white, textured wood finish and other decorative finishes are available. A laminated aluminium metallic coating is also indicated as an option.
Colours displayed on screen are for reference only. When the shade is critical, a real sample should be checked before confirming the order.
Installation of the plain red tile-effect sandwich panel must be carried out on a properly sized structure with a minimum slope of 10%.
In more severe environments, the technical documentation recommends applying silicone to the panel joint to help prevent condensation.
Important: admissible spans must be verified using the load tables and the actual conditions of each roof.
DECLARED PERFORMANCE
| Configuration | Tile-effect insulated roof panel |
|---|---|
| Manufacturing standard | EN 14509 · CE marking |
| Minimum slope | 10% |
| Thicknesses | 30, 40 and 50 mm (±2 mm) |
| Useful width | 1,000 mm (±2 mm) |
| Length | 2.10 to 14.00 m, made to measure in multiples of 0.35 m · recommended up to 8.05 m |
| Wave | 50 mm high · 200 mm pitch · 350 mm longitudinal module |
| Steel sheet | S250GD, galvanised |
| Sheet thicknesses | 0.4 / 0.5 / 0.6 mm |
| Core | PUR or PIR · 40 kg/m³ |
| Thermal conductivity | λ = 0.0207 W/m·K |
| Reaction to fire | PIR: B-s2,d0 · high-performance PIR: B-s1,d0 · PUR: not certified |
| Coating | 25 µm textured polyester · 55 µm special coating |
| Inner face | Ribbed or planked profile · optional 180 µm wood-effect PVC or pre-painted aluminium |
| Colours | Plain red, RAL 8004 · inner face RAL 9010 or planked wood finish · other RAL colours on request |
| Thickness | U-value (W/m²·K) | Weight 0.5/0.4 (kg/m²) | Weight 0.5/0.5 (kg/m²) |
|---|---|---|---|
| 30 mm | 0.45 | 10.8 | 11.7 |
| 40 mm | 0.37 | 11.2 | 12.1 |
| 50 mm | 0.31 | 11.6 | 12.5 |
The data sheet includes uniformly distributed load tables for spans from 1.05 to 3.50 m, distinguishing between upward and downward load, single or multiple support, and sheet configurations of 0.5/0.4 and 0.5/0.5 mm.
These tables are a technical reference and do not replace the project calculation. Actual wind, snow and maintenance loads, number of supports and specific roof conditions must be verified.
Scroll the table
| Thickness | Load | Admissible load (kN/m²) according to distance between supports L (m) | |||||||
|---|---|---|---|---|---|---|---|---|---|
| 1.05 m | 1.40 m | 1.75 m | 2.10 m | 2.45 m | 2.80 m | 3.15 m | 3.50 m | ||
| 30 mm | ▲ | 2,52 | 1,55 | 1,08 | 0,81 | 0,64 | 0,52 | 0,44 | 0,37 |
| ▼ | 1,86 | 1,10 | 0,73 | 0,51 | 0,37 | — | — | — | |
| 40 mm | ▲ | 2,69 | 1,70 | 1,21 | 0,92 | 0,73 | 0,60 | 0,51 | 0,43 |
| ▼ | 1,98 | 1,20 | 0,81 | 0,59 | 0,44 | 0,33 | — | — | |
| 50 mm | ▲ | 2,86 | 1,85 | 1,35 | 1,04 | 0,84 | 0,69 | 0,58 | 0,50 |
| ▼ | 2,11 | 1,32 | 0,91 | 0,67 | 0,50 | 0,39 | 0,30 | — | |
Scroll the table
| Thickness | Load | Admissible load (kN/m²) according to distance between supports L (m) | |||||||
|---|---|---|---|---|---|---|---|---|---|
| 1.05 m | 1.40 m | 1.75 m | 2.10 m | 2.45 m | 2.80 m | 3.15 m | 3.50 m | ||
| 30 mm | ▲ | 2,52 | 1,53 | 0,96 | 0,67 | 0,50 | 0,40 | 0,33 | — |
| ▼ | 1,86 | 1,10 | 0,73 | 0,51 | 0,37 | — | — | — | |
| 40 mm | ▲ | 2,69 | 1,68 | 1,07 | 0,73 | 0,54 | 0,43 | 0,35 | — |
| ▼ | 1,86 | 1,10 | 0,73 | 0,51 | 0,37 | — | — | — | |
| 50 mm | ▲ | 2,86 | 1,85 | 1,20 | 0,82 | 0,63 | 0,50 | 0,40 | — |
| ▼ | 1,86 | 1,10 | 0,73 | 0,51 | 0,37 | — | — | — | |
Scroll the table
| Thickness | Load | Admissible load (kN/m²) according to distance between supports L (m) | |||||||
|---|---|---|---|---|---|---|---|---|---|
| 1.05 m | 1.40 m | 1.75 m | 2.10 m | 2.45 m | 2.80 m | 3.15 m | 3.50 m | ||
| 30 mm | ▲ | 2,52 | 1,55 | 1,08 | 0,81 | 0,64 | 0,53 | 0,44 | 0,38 |
| ▼ | 1,86 | 1,10 | 0,73 | 0,51 | 0,38 | — | — | — | |
| 40 mm | ▲ | 2,69 | 1,70 | 1,21 | 0,93 | 0,74 | 0,61 | 0,51 | 0,44 |
| ▼ | 1,98 | 1,21 | 0,82 | 0,59 | 0,44 | 0,33 | — | — | |
| 50 mm | ▲ | 2,87 | 1,86 | 1,35 | 1,05 | 0,84 | 0,70 | 0,59 | 0,51 |
| ▼ | 2,11 | 1,32 | 0,92 | 0,67 | 0,51 | 0,39 | 0,30 | — | |
Scroll the table
| Thickness | Load | Admissible load (kN/m²) according to distance between supports L (m) | |||||||
|---|---|---|---|---|---|---|---|---|---|
| 1.05 m | 1.40 m | 1.75 m | 2.10 m | 2.45 m | 2.80 m | 3.15 m | 3.50 m | ||
| 30 mm | ▲ | 2,52 | 1,54 | 0,97 | 0,68 | 0,50 | 0,40 | 0,33 | — |
| ▼ | 1,86 | 1,10 | 0,73 | 0,51 | 0,38 | — | — | — | |
| 40 mm | ▲ | 2,69 | 1,69 | 1,08 | 0,73 | 0,54 | 0,43 | 0,35 | — |
| ▼ | 1,98 | 1,21 | 0,82 | 0,59 | 0,44 | 0,33 | — | — | |
| 50 mm | ▲ | 2,87 | 1,86 | 1,21 | 0,82 | 0,63 | 0,50 | 0,40 | 0,30 |
| ▼ | 2,11 | 1,32 | 0,92 | 0,67 | 0,51 | 0,39 | 0,30 | — | |
DATA SHEET
Download the full data sheet for the plain red tile-effect sandwich panel to check dimensions, thicknesses, modulation, thermal behaviour, weights, colours, finishes and load tables.
The document should be used as a technical reference together with the specific conditions of each project.
QUESTIONS
It is an insulating roof panel with a geometry inspired by traditional roof tiles and a textured exterior finish. The plain red finish, in RAL 8004 shade, offers a uniform, classic tile colour.
The minimum slope stated in the data sheet is 10%. The project must also take into account the geometry, joints, flashing elements and the climatic conditions of the site.
The technical documentation includes thicknesses of 30, 40 and 50 mm, with an indicated tolerance of ±2 mm.
The declared thermal transmittance is 0.45 W/m²·K at 30 mm, 0.37 W/m²·K at 40 mm and 0.31 W/m²·K at 50 mm.
Manufacturing length ranges from 2.10 to 14.00 m in multiples of 0.35 m. The recommended maximum length stated in the data sheet is 8.05 m.
In addition to plain red, the data sheet includes RAL 8004 tile red, RAL 8023 light tile red, RAL 9005 intense black and various aged or decorative finishes. For the interior face, RAL 9010 pure white and textured wood finish are included.
FLASHING FOR TILE-EFFECT PANEL
LATEST ARTICLES
Browse content on panel selection, insulation, installation, maintenance, refurbishment and real-world applications.
YOU MAY ALSO BE INTERESTED IN
ON-SITE SERVICE
We quote for new builds, refurbishment, roof and facade replacement, flashing installation, and work with sheet metal or skylights.
The quote depends on geometry, height, access, auxiliary equipment, location, fixings and junctions the job must resolve.